Literature DB >> 22284286

Primary stability and histomorphometric bone-implant contact of self-drilling and self-tapping orthodontic microimplants.

Seçil Çehreli1, Ayça Arman-Özçırpıcı.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the primary stability and the histomorphometric measurements of self-drilling and self-tapping orthodontic microimplants and the correlations between factors related to host, implant, and measuring technique.
METHODS: Seventy-two self-drilling and self-tapping implants were placed into bovine iliac crest blocks after computed tomography assessments. Insertion torque values, subjective assessments of stability, and Periotest (Medizintecknik Gulden, Modautal, Germany) measurements were performed for each implant. Twelve specimens of each group were assigned to histologic and histomorphometric assessments.
RESULTS: The differences between insertion torque values, most Periotest values, and subjective assessments of stability scores were insignificant (P >0.05). The bone-implant contact percentage of the self-drilling group (87.60%) was higher than that of the self-tapping group (80.73%) (P <0.05). Positive correlations were found between insertion torque value, cortical bone thickness, and density in both groups (P <0.05). Negative correlations between insertion torque values and Periotest values were mostly observed in the self-drilling group (P <0.05). Positive correlations were found between bone-implant contact percentages, cortical bone densities, and insertion torque values in both groups (P <0.05). The differences between insertion torque values and corresponding subjective assessments of stability scores were different in both groups (P <0.05).
CONCLUSIONS: The differences in insertion torque values, Periotest values, and subjective assessments of stability scores of self-drilling and self-tapping implants were insignificant. Self-drilling implants had higher bone-implant contact percentages than did self-tapping implants. Significant correlations were found between parameters influencing the primary stability of the implants.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22284286     DOI: 10.1016/j.ajodo.2011.07.020

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  14 in total

1.  Roughness and wettability effect on histological and mechanical response of self-drilling orthodontic mini-implants.

Authors:  Eduardo Espinar-Escalona; Luis-Alberto Bravo-Gonzalez; Marta Pegueroles; Francisco Javier Gil
Journal:  Clin Oral Investig       Date:  2016-03-09       Impact factor: 3.573

2.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

3.  Mechanical stability of orthodontic miniscrew depends on a thread shape.

Authors:  Keiichiro Watanabe; Bobby Mitchell; Takuma Sakamaki; Yuzo Hirai; Do-Gyoon Kim; Toru Deguchi; Masakazu Suzuki; Kanji Ueda; Eiji Tanaka
Journal:  J Dent Sci       Date:  2021-12-11       Impact factor: 3.719

4.  Stability of smooth and rough mini-implants: clinical and biomechanical evaluation - an in vivostudy.

Authors:  Giselle Naback Lemes Vilani; Antônio Carlos de Oliveira Ruellas; Carlos Nelson Elias; Cláudia Trindade Mattos
Journal:  Dental Press J Orthod       Date:  2015-10

5.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

6.  Interradicular trabecular bone density of the lateral maxilla for temporary anchorage devices--a histomorphometric study.

Authors:  Elena Krieger; Heinrich Wehrbein
Journal:  Head Face Med       Date:  2015-02-07       Impact factor: 2.151

7.  Evaluation of primary stability of innovated orthodontic miniscrew system (STS): An ex-vivo study.

Authors:  Massoud Seifi; Negin-Sadat Matini
Journal:  J Clin Exp Dent       Date:  2016-07-01

8.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06

9.  The effect of insertion angle on orthodontic mini-screw torque.

Authors:  Seyed Hamid Raji; Saeed Noorollahian; Seyed Mohsen Niknam
Journal:  Dent Res J (Isfahan)       Date:  2014-07

Review 10.  Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Authors:  Mariana Marquezan; Cláudia Trindade Mattos; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza; Lucianne Cople Maia
Journal:  Angle Orthod       Date:  2014-04-02       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.