Literature DB >> 22196187

Analysis of stress in bone and microimplants during en-masse retraction of maxillary and mandibular anterior teeth with different insertion angulations: a 3-dimensional finite element analysis study.

M Issa Fathima Jasmine1, A Arif Yezdani, Faisal Tajir, R Murali Venu.   

Abstract

INTRODUCTION: The proper angle of microimplant insertion is important for cortical anchorage, patient safety, and biomechanical control. However, the actual impact of different insertion angulations on stability is unknown.
METHODS: To perform 3-dimensional finite element analysis, finite element models of a maxilla and a mandible with types D3 and D2 bone quality, and of microimplants with a diameter of 1.3 mm and lengths of 8 and 7 mm were generated. The microimplants were inserted at 30°, 45°, 60°, and 90° to the bone surface. A simulated horizontal orthodontic force of 200 g was applied to the center of the microimplant head, and stress distribution and its magnitude were analyzed with a 3-dimensional finite element analysis program.
RESULTS: The maximum von Mises stresses in the microimplant and the cortical bone decreased as the insertion angle increased. Analysis of the stress distribution in the cortical and cancellous bones showed that the stress was absorbed mostly in the cortical bone, and little was transmitted to the cancellous bone. The maximum von Mises stress was higher in type D3 bone quality than type D2 bone quality.
CONCLUSIONS: Placement of microimplants at a 90° angulation in the bone reduces the stress concentration, thereby increasing the likelihood of implant stabilization. Perpendicular insertion offers more stability to orthodontic loading.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22196187     DOI: 10.1016/j.ajodo.2011.06.031

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  13 in total

1.  Evaluation of Stress Pattern Caused by Mini-Implant in Mandibular Alveolar Bone with Different Angulations and Retraction Forces: A Three-Dimensional Finite Element Study.

Authors:  Manreet Sidhu; Vinay Kumar Chugh; Kuldeep Dmello; Anurag Mehta; Ankita Chugh; Pradeep Tandon
Journal:  Turk J Orthod       Date:  2020-07-18

2.  Analysis for Predictors of Failure of Orthodontic Mini-implant Using Patient-Specific Finite Element Models.

Authors:  Takahiro Toriya; Toru Kitahara; Hiroto Hyakutake; Mitsugu Todo; Ichiro Takahashi
Journal:  Ann Biomed Eng       Date:  2022-09-27       Impact factor: 4.219

3.  Effect of vertical placement angle on the insertion torque of mini-implants in human alveolar bone.

Authors:  Rafael Ribeiro Maya; Célia Regina Maio Pinzan-Vercelino; Julio de Araujo Gurgel
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

4.  Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles.

Authors:  Sung-Hwan Choi; Seong-Jin Kim; Kee-Joon Lee; Sang-Jin Sung; Youn-Sic Chun; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2016-07-25       Impact factor: 1.372

5.  Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

Authors:  Ying-juan Lu; Shao-hai Chang; Jian-tao Ye; Yu-shan Ye; Yan-song Yu
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

6.  Evaluating the effects of consolidation on intrusion and retraction using temporary anchorage devices-a FEM study.

Authors:  Monica Namburi; Sleevaraju Nagothu; Chetan S Kumar; N Chakrapani; C H Hanumantharao; Supradeep K Kumar
Journal:  Prog Orthod       Date:  2017-01-09       Impact factor: 2.750

7.  Evaluation of stress generation on the cortical bone and the palatal micro-implant complex during the implant-supported en masse retraction in lingual orthodontic technique using the FEM: Original research.

Authors:  Tarulatha Revanappa Shyagali; Dhaval Aghera
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2019-10-07

8.  Effects of Skeletally Supported Anterior en Masse Retraction with Varied Lever Arm Lengths and Locations in Lingual Orthodontic Treatment: A 3D Finite Element Study.

Authors:  Mohammad Ghannam; Beste Kamiloğlu
Journal:  Biomed Res Int       Date:  2021-05-17       Impact factor: 3.411

9.  Class I malocclusion with severe double protrusion treated with first premolars extraction.

Authors:  Ricardo Moresca
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

10.  The effect of insertion angle on orthodontic mini-screw torque.

Authors:  Seyed Hamid Raji; Saeed Noorollahian; Seyed Mohsen Niknam
Journal:  Dent Res J (Isfahan)       Date:  2014-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.