PURPOSE: To develop a cardiac and respiratory self-gated four-dimensional (4D) coronary MRA technique for simultaneous cardiac anatomy and function visualization. METHODS: A contrast-enhanced, ungated spoiled gradient echo sequence with self-gating (SG) and 3DPR trajectory was used for image acquisition. Data were retrospectively binned into different cardiac and respiratory phases based on information extracted from SG projections using principal component analysis. Each cardiac phase was reconstructed using a respiratory motion-corrected self-calibrating SENSE framework, and those belong to the quiescent period were retrospectively combined for coronary visualization. Healthy volunteer studies were conducted to evaluate the efficacy of the SG method, the accuracy of the left ventricle (LV) function parameters and the quality of coronary artery visualization. RESULTS: SG performed reliably for all subjects including one with poor electrocardiogram (ECG). The LV function parameters showed excellent agreement with those from a conventional cine protocol. For coronary imaging, the proposed method yielded comparable apparent signal to noise ratio and coronary sharpness and lower apparent contrast to noise ratio on three subjects compared with an ECG and navigator-gated Cartesian protocol and an ECG-gated, respiratory motion-corrected 3DPR protocol. CONCLUSION: A fully self-gated 4D whole-heart imaging technique was developed, potentially allowing cardiac anatomy and function assessment from a single measurement.
PURPOSE: To develop a cardiac and respiratory self-gated four-dimensional (4D) coronary MRA technique for simultaneous cardiac anatomy and function visualization. METHODS: A contrast-enhanced, ungated spoiled gradient echo sequence with self-gating (SG) and 3DPR trajectory was used for image acquisition. Data were retrospectively binned into different cardiac and respiratory phases based on information extracted from SG projections using principal component analysis. Each cardiac phase was reconstructed using a respiratory motion-corrected self-calibrating SENSE framework, and those belong to the quiescent period were retrospectively combined for coronary visualization. Healthy volunteer studies were conducted to evaluate the efficacy of the SG method, the accuracy of the left ventricle (LV) function parameters and the quality of coronary artery visualization. RESULTS: SG performed reliably for all subjects including one with poor electrocardiogram (ECG). The LV function parameters showed excellent agreement with those from a conventional cine protocol. For coronary imaging, the proposed method yielded comparable apparent signal to noise ratio and coronary sharpness and lower apparent contrast to noise ratio on three subjects compared with an ECG and navigator-gated Cartesian protocol and an ECG-gated, respiratory motion-corrected 3DPR protocol. CONCLUSION: A fully self-gated 4D whole-heart imaging technique was developed, potentially allowing cardiac anatomy and function assessment from a single measurement.
Authors: Michael S Hansen; Christof Baltes; Jeffrey Tsao; Sebastian Kozerke; Klaas P Pruessmann; Holger Eggers Journal: Magn Reson Med Date: 2006-01 Impact factor: 4.668
Authors: Jing Liu; Thanh D Nguyen; Yanchun Zhu; Pascal Spincemaille; Martin R Prince; Jonathan W Weinsaft; David Saloner; Yi Wang Journal: PLoS One Date: 2014-02-20 Impact factor: 3.240
Authors: Christoph Kolbitsch; Mark A Ahlman; Cynthia Davies-Venn; Robert Evers; Michael Hansen; Devis Peressutti; Paul Marsden; Peter Kellman; David A Bluemke; Tobias Schaeffter Journal: J Nucl Med Date: 2017-02-09 Impact factor: 10.057
Authors: Moritz H Albrecht; Akos Varga-Szemes; U Joseph Schoepf; Georg Apfaltrer; Jiaqian Xu; Kwang-Nam Jin; Anthony M Hlavacek; Shahryar M Chowdhury; Pal Suranyi; Christian Tesche; Carlo N De Cecco; Davide Piccini; Matthias Stuber; Giulia Ginami; Thomas J Vogl; Arni Nutting Journal: Eur Radiol Date: 2017-09-08 Impact factor: 5.315