Literature DB >> 11274569

Coronary arteries: magnetization-prepared contrast-enhanced three-dimensional volume-targeted breath-hold MR angiography.

D Li1, J C Carr, S M Shea, J Zheng, V S Deshpande, P A Wielopolski, J P Finn.   

Abstract

A volume-targeted contrast agent-enhanced breath-hold coronary magnetic resonance angiographic technique was optimized and evaluated in 16 volunteers. Substantial increases in coronary signal-to-noise ratio, contrast-to-noise ratio, lengths of depiction, and vessel sharpness were observed on enhanced images. The imaging approach with two 20-mL injections of contrast agent covers the left and right coronary arteries in two breath holds and is a promising method for coronary imaging.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11274569     DOI: 10.1148/radiology.219.1.r01ap37270

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  36 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Toward comparability of coronary magnetic resonance angiography: proposal for a standardized quantitative assessment.

Authors:  Martijn S Dirksen; Hildo J Lamb; Rob van der Geest; Albert de Roos
Journal:  Eur Radiol       Date:  2003-08-02       Impact factor: 5.315

Review 3.  Magnetic resonance coronary angiography.

Authors:  Phillip C Yang; Michael V McConnell; Dwight G Nishimura; Bob S Hu
Journal:  Curr Cardiol Rep       Date:  2003-01       Impact factor: 2.931

4.  Highly undersampled peripheral Time-of-Flight magnetic resonance angiography: optimized data acquisition and iterative image reconstruction.

Authors:  Jana Hutter; Robert Grimm; Christoph Forman; Joachim Hornegger; Peter Schmitt
Journal:  MAGMA       Date:  2015-01-22       Impact factor: 2.310

5.  Whole-heart coronary magnetic resonance angiography at 3.0T using short-TR steady-state free precession, vastly undersampled isotropic projection reconstruction.

Authors:  Jingsi Xie; Peng Lai; Himanshu Bhat; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

6.  A post-processing method based on interphase motion correction and averaging to improve image quality of 4D magnetic resonance imaging: a clinical feasibility study.

Authors:  Zixin Deng; Jianing Pang; Yi Lao; Xiaoming Bi; Guan Wang; Yuhua Chen; Matthias Fenchel; Richard Tuli; Debiao Li; Wensha Yang; Zhaoyang Fan
Journal:  Br J Radiol       Date:  2019-01-03       Impact factor: 3.039

7.  Three-dimensional breathhold magnetization-prepared TrueFISP: a pilot study for magnetic resonance imaging of the coronary artery disease.

Authors:  Richard M McCarthy; Vibhas S Deshpande; Nirat Beohar; Sheridan N Meyers; Steven M Shea; Jordin D Green; Xin Liu; Xiaoming Bi; F Scott Pereles; John Paul Finn; Charles J Davidson; James C Carr; Debiao Li
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

8.  Free-breathing, non-ECG, continuous myocardial T1 mapping with cardiovascular magnetic resonance multitasking.

Authors:  Jaime L Shaw; Qi Yang; Zhengwei Zhou; Zixin Deng; Christopher Nguyen; Debiao Li; Anthony G Christodoulou
Journal:  Magn Reson Med       Date:  2018-11-19       Impact factor: 4.668

9.  Accelerated isotropic sub-millimeter whole-heart coronary MRI: compressed sensing versus parallel imaging.

Authors:  Mehmet Akçakaya; Tamer A Basha; Raymond H Chan; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

10.  High efficiency coronary MR angiography with nonrigid cardiac motion correction.

Authors:  Jianing Pang; Yuhua Chen; Zhaoyang Fan; Christopher Nguyen; Qi Yang; Yibin Xie; Debiao Li
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.