An analysis of the head-neck taper interface in retrieved hip prostheses.

J R Lieberman1, C M Rimnac, K L Garvin, R W Klein, E A Salvati.   

Abstract

The purpose of this study was to examine the mating surfaces of femoral heads and stems for evidence of corrosion, and to evaluate the quality of the taper lock of modular hip prostheses. Forty-eight implants with three different designs were evaluated. Group I (26 implants) had a cobalt alloy head and cobalt alloy stem. Group II (ten implants) had a cobalt alloy head and a titanium stem. Group III (12 implants) had a cobalt alloy head with a titanium stem that was coupled in the factory via a shrink fit. The implants were examined under light microscopy and scanning electron microscopy. In cases where the femoral head was still assembled to the stem, pull-off testing was performed using an MTS machine. The average failure load for the pull-off tests for each group of prostheses was as follows: Group I (nine implants) 3,003 N +/- 623 N; Group II (six implants) 4453 N +/- 570 N; and Group III (12 implants) 6859 N +/- 3525 N. The Group III implants required a significantly greater pull-off force than those in Group I (p = 0.002). There was no evidence of corrosion in Group I. In Group II, crevice corrosion was noted in one taper interface and there was fretting in two other tapers. No corrosion was noted in Group III. Improving the tolerances of the mating surfaces may be a key factor in preventing corrosion. This would not only increase the forces that are necessary to debond the matting surfaces, but also decrease corrosion by reducing micromotion and fluid at the taper interface.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8131330

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  19 in total

1.  Impending spontaneous head neck dissociation caused by anteverted cup: A case report on reverse bottle opener effect and review of literature.

Authors:  Ramneek Mahajan; Piyush Suresh Nashikkar; Varun Khanna
Journal:  J Clin Orthop Trauma       Date:  2020-11-01

2.  Characterization of Femoral Head Taper Corrosion Features Using a 22-Year Retrieval Database.

Authors:  Jacob Cartner; Patrick Aldinger; Chenxi Li; David Collins
Journal:  HSS J       Date:  2016-08-12

3.  Modern trunnions are more flexible: a mechanical analysis of THA taper designs.

Authors:  David A Porter; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert; José A Rodriguez; H John Cooper
Journal:  Clin Orthop Relat Res       Date:  2014-09-30       Impact factor: 4.176

4.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

5.  The effect of manufacturing tolerances on the mechanical environment of taper junctions in modular TKR.

Authors:  Kyle Snethen; Jorge Hernandez; Melinda Harman
Journal:  J Mech Behav Biomed Mater       Date:  2019-04-18

6.  Severe metal-induced osteolysis many years after unipolar hip endoprosthesis.

Authors:  Matthew A Mann; Dylan Tanzer; Michael Tanzer
Journal:  Clin Orthop Relat Res       Date:  2013-01-05       Impact factor: 4.176

7.  Adverse local tissue reaction arising from corrosion at the femoral neck-body junction in a dual-taper stem with a cobalt-chromium modular neck.

Authors:  H John Cooper; Robert M Urban; Richard L Wixson; R Michael Meneghini; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2013-05-15       Impact factor: 5.284

8.  Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty.

Authors:  H John Cooper; Craig J Della Valle; Richard A Berger; Matthew Tetreault; Wayne G Paprosky; Scott M Sporer; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2012-09-19       Impact factor: 5.284

9.  In vivo severe corrosion and hydrogen embrittlement of retrieved modular body titanium alloy hip-implants.

Authors:  Danieli C Rodrigues; Robert M Urban; Joshua J Jacobs; Jeremy L Gilbert
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-01       Impact factor: 3.368

10.  Modular titanium alloy neck adapter failures in hip replacement--failure mode analysis and influence of implant material.

Authors:  Thomas M Grupp; Thomas Weik; Wilhelm Bloemer; Hanns-Peter Knaebel
Journal:  BMC Musculoskelet Disord       Date:  2010-01-04       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.