Literature DB >> 25159635

Evaluation of emissivity and temperature profile of laparoscopic ultrasonic devices (blades and passive jaws).

Fernando J Kim1, David Sehrt, Rodrigo Donalisio da Silva, Diedra Gustafson, Leticia Nogueira, Wilson R Molina.   

Abstract

OBJECTIVES: We examined the emissivity and temperature profile of passive and active jaws of various laparoscopic ultrasonic devices during cutting, coagulation, and cooling time.
METHODS: The Harmonic ACE™ (ACE), Covidien Sonicision™ (SNC), and Olympus SonoSurg™ (SS) were applied using pre-set factory cutting and coagulation settings to Bovine mesentery and Lamb renal veins, respectively. The maximum temperature and cooling time to reach 60 °C were recorded using an infrared Fluke Ti55 thermal imager. Histological examination was evaluated after application of energy.
RESULTS: The ACE, Sonicision, and SonoSurg had emissivity measurements of 0.49 ± 0.01, 0.40 ± 0.00, and 0.39 ± 0.01, respectively. Maximum cutting temperatures were: ACE = 191.1°, SNC = 227.1°, and SNS 184.8° * (*p < 0.001). Maximum coagulation temperatures did not differ significantly among devices (p = 0.490). The cooling time to reach 60 °C after activation were 35.7 s (ACE), 38.7 s (SNC), and 27.4 s* (SS) (*p < 0.001). The cooling time of passive jaws to reach 60 °C after activation were 25.4 s* (ACE), 5.7 s (SNC), and 15.4 s (SS) (*p < 0.001).
CONCLUSION: Laparoscopic ultrasonic instruments obtain the same cutting and coagulation objectives but in different manners. The Sonicision improves cutting by getting the blade hotter while the SonoSurg has more precise coagulation effects by heating slower. Emissivity values varied among instruments, providing equally varied results. Depending on the purpose of the devices, a certain device may be more appropriate. Based on emissivity, more studies are needed to identify the ideal material that can predictably and effectively perform in clinical settings. Although different blade geometry is apparent between instruments, the jaws are also designed differently between the generations of instruments.

Entities:  

Mesh:

Year:  2014        PMID: 25159635     DOI: 10.1007/s00464-014-3787-0

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  10 in total

1.  How safe is high-power ultrasonic dissection?

Authors:  Tarek A Emam; Alfred Cuschieri
Journal:  Ann Surg       Date:  2003-02       Impact factor: 12.969

2.  Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT).

Authors:  F J Kim; M F Chammas; E Gewehr; M Morihisa; F Caldas; E Hayacibara; M Baptistussi; F Meyer; A C Martins
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

3.  Thermal spread and heat absorbance differences between open and laparoscopic surgeries during energized dissections by electrosurgical instruments.

Authors:  C Song; B Tang; P A Campbell; A Cuschieri
Journal:  Surg Endosc       Date:  2009-03-19       Impact factor: 4.584

4.  The harmonic scalpel: an intraoperative complication.

Authors:  J T Awwad; K Isaacson
Journal:  Obstet Gynecol       Date:  1996-10       Impact factor: 7.661

5.  Physics of ultrasonic surgery using tissue fragmentation: Part I.

Authors:  W W Cimino; L J Bond
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

6.  Proximity injury by the ultrasonically activated scalpel during dissection.

Authors:  K M Kadesky; B Schopf; J F Magee; G K Blair
Journal:  J Pediatr Surg       Date:  1997-06       Impact factor: 2.545

7.  Evaluation of an innovative, cordless ultrasonic dissector.

Authors:  Victor B Tsirline; Kelvin N Lau; Ryan Z Swan; Paul N Montero; David Sindram; John B Martinie; David A Iannitti
Journal:  Surg Innov       Date:  2013-01-08       Impact factor: 2.058

8.  Safety and efficacy of new integrated bipolar and ultrasonic scissors compared to conventional laparoscopic 5-mm sealing and cutting instruments.

Authors:  Daniel Seehofer; Martina Mogl; Sabine Boas-Knoop; Juliane Unger; Anja Schirmeier; Sascha Chopra; Dennis Eurich
Journal:  Surg Endosc       Date:  2012-03-24       Impact factor: 4.584

9.  Comparison of surgical plume among laparoscopic ultrasonic dissectors using a real-time digital quantitative technology.

Authors:  Fernando J Kim; David Sehrt; Alexandre Pompeo; Wilson R Molina
Journal:  Surg Endosc       Date:  2012-06-04       Impact factor: 4.584

10.  Ultrasonic scalpel causes greater depth of soft tissue necrosis compared to monopolar electrocautery at standard power level settings in a pig model.

Authors:  Kia Homayounfar; Johanna Meis; Klaus Jung; Bernd Klosterhalfen; Thilo Sprenger; Lena-Christin Conradi; Claus Langer; Heinz Becker
Journal:  BMC Surg       Date:  2012-02-23       Impact factor: 2.102

  10 in total
  5 in total

Review 1.  Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Authors:  Rajesh Devassy; Sreelatha Gopalakrishnan; Rudy Leon De Wilde
Journal:  J Obstet Gynaecol India       Date:  2015-09-14

2.  Modification of the Thermal Spread by the Blade Shape of an Ultrasonically Activated Device.

Authors:  Shuhei Kajiwara; Hirokazu Noshiro; Hiroshi Kitagawa; Tomokazu Tanaka; Keita Kai
Journal:  World J Surg       Date:  2021-02-17       Impact factor: 3.352

Review 3.  Current issues in patient safety in surgery: a review.

Authors:  Fernando J Kim; Rodrigo Donalisio da Silva; Diedra Gustafson; Leticia Nogueira; Timothy Harlin; David L Paul
Journal:  Patient Saf Surg       Date:  2015-06-05

4.  Safety Profile of the New Harmonic Focus: Different Emissivity and Temperature Behavior Between the Active and the Inactive Blade.

Authors:  Saverio Latteri; Giuseppe Stella; Anna M Gueli; Stefania Mazzaglia; Valentina Palumbo; Tommaso Guastella
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2019-10       Impact factor: 1.719

5.  Current status on the adoption of high energy devices in Italy: An Italian Society for Endoscopic Surgery and New Technologies (SICE) national survey.

Authors:  Emanuele Botteri; Mauro Podda; Alberto Arezzo; Nereo Vettoretto; Alberto Sartori; Antonino Agrusa; Marco Ettore Allaix; Gabriele Anania; Riccardo Brachet Contul; Valerio Caracino; Elisa Cassinotti; Diego Cuccurullo; Giancarlo D'Ambrosio; Marco Milone; Irnerio Muttillo; Wanda Luisa Petz; Marcello Pisano; Mario Guerrieri; Gianfranco Silecchia; Ferdinando Agresta
Journal:  Surg Endosc       Date:  2020-11-05       Impact factor: 4.584

  5 in total