Literature DB >> 23302577

Evaluation of an innovative, cordless ultrasonic dissector.

Victor B Tsirline1, Kelvin N Lau, Ryan Z Swan, Paul N Montero, David Sindram, John B Martinie, David A Iannitti.   

Abstract

Ultrasonic thermal energy is commonly used for dissection and vessel ligation. This study compared HARMONIC ACE and Sonicision Cordless Ultrasonic Dissector (SCUD). The devices were used in an in vivo porcine model to coagulate 189 arteries up to 5 mm. Seal times were similar: SCUD, 5.2 ± 1.7 s; ACE, 4.9 ± 1.5 s (P = .20). Burst pressures for SCUD and AVE were 578 ± 284 and 605 ± 288 mm Hg, respectively (P = .48). Stratification by vessel diameter yielded similar results. In all, 17 applications resulted in seal failure on either the proximal or distal side, with no difference between SCUD (4.4%) and ACE (6.6%; P = .37). Histological examination of 48 specimens showed similar thermal spreads: 1.06 ± 0.05 versus 1.08 ± 0.05 mm for SCUD and ACE, respectively (P = .82). In 41 timed mesenteric transections, SCUD required 24.8 ± 4.9 s, which was significantly less than the 33.8 ± 5.4 s for ACE (P < .0001), with no bleeding in either group. SCUD and ACE showed similar vessel seal times, burst pressures, thermal spreads, and seal failure rates. SCUD was more efficient than ACE in mesenteric transection.

Entities:  

Keywords:  biomedical engineering; ergonomics and/or human factors study; gastric surgery

Mesh:

Year:  2013        PMID: 23302577     DOI: 10.1177/1553350612471206

Source DB:  PubMed          Journal:  Surg Innov        ISSN: 1553-3506            Impact factor:   2.058


  5 in total

1.  Modification of the Thermal Spread by the Blade Shape of an Ultrasonically Activated Device.

Authors:  Shuhei Kajiwara; Hirokazu Noshiro; Hiroshi Kitagawa; Tomokazu Tanaka; Keita Kai
Journal:  World J Surg       Date:  2021-02-17       Impact factor: 3.352

2.  Evaluation of emissivity and temperature profile of laparoscopic ultrasonic devices (blades and passive jaws).

Authors:  Fernando J Kim; David Sehrt; Rodrigo Donalisio da Silva; Diedra Gustafson; Leticia Nogueira; Wilson R Molina
Journal:  Surg Endosc       Date:  2014-08-27       Impact factor: 4.584

3.  Experimental analyses of the cavitation generated by ultrasonically activated surgical devices.

Authors:  Tao Gao; Bik Ee Lau; Tadashi Yamaguchi; Naoyuki Hanari; Hisashi Gunji; Masayuki Kano; Hisahiro Matsubara; Hideki Hayashi
Journal:  Surg Today       Date:  2016-05-06       Impact factor: 2.549

Review 4.  Clinical use of a cordless laparoscopic ultrasonic device.

Authors:  Fernando J Kim; David Sehrt; Wilson R Molina; Alexandre Pompeo
Journal:  JSLS       Date:  2014 Jul-Sep       Impact factor: 2.172

5.  Current status on the adoption of high energy devices in Italy: An Italian Society for Endoscopic Surgery and New Technologies (SICE) national survey.

Authors:  Emanuele Botteri; Mauro Podda; Alberto Arezzo; Nereo Vettoretto; Alberto Sartori; Antonino Agrusa; Marco Ettore Allaix; Gabriele Anania; Riccardo Brachet Contul; Valerio Caracino; Elisa Cassinotti; Diego Cuccurullo; Giancarlo D'Ambrosio; Marco Milone; Irnerio Muttillo; Wanda Luisa Petz; Marcello Pisano; Mario Guerrieri; Gianfranco Silecchia; Ferdinando Agresta
Journal:  Surg Endosc       Date:  2020-11-05       Impact factor: 4.584