Proximity injury by the ultrasonically activated scalpel during dissection.

K M Kadesky1, B Schopf, J F Magee, G K Blair.   

Abstract

The ultrasonically activated scalpel is a high-frequency oscillating instrument that is reported to have a decreased dispersion of energy to surrounding tissues during use. To determine if this effect is beneficial and safe to surrounding tissue, it was used on anesthetized adolescent swine to dissect the portal vein from the pancreas, the renal artery and vein from the renal hilum, the ureter from the retroperitoneum, the aorta from the inferior vena cava and the common bile duct from surrounding tissue. Three-second contact to intestine and nerve roots was also performed. Wedge biopsy specimens of liver and spleen were performed. Dissection technique used was as described by the company. Structures were dissected with electrocautery using similar techniques for comparison. Tissues were harvested and placed in formalin for histological analysis. Dissection with the ultrasonically activated scalpel was simple, achieved excellent hemostasis, and did not appear to damage adjacent tissue. Microscopic analysis showed adventicial and media injury to vascular structures. The ureter and common bile duct demonstrated marked injury with regions of transmural coagulation. Nerve and small bowel did not appear to have much injury from the 3-second contact with the instrument. This study indicated that although the ultrasonically activated scalpel can ease dissection with good hemostasis, care must be taken to avoid injury to adjacent structures. Although its lateral energy dispersion may be less than that of cautery, it can still cause transmural necrosis to major structures.

Entities:  

Mesh:

Year:  1997        PMID: 9200091     DOI: 10.1016/s0022-3468(97)90641-2

Source DB:  PubMed          Journal:  J Pediatr Surg        ISSN: 0022-3468            Impact factor:   2.545


  12 in total

1.  How safe is high-power ultrasonic dissection?

Authors:  Tarek A Emam; Alfred Cuschieri
Journal:  Ann Surg       Date:  2003-02       Impact factor: 12.969

Review 2.  Surgical Efficacy Among Laparoscopic Ultrasonic Dissectors: Are We Advancing Safely? A Review of Literature.

Authors:  Rajesh Devassy; Sreelatha Gopalakrishnan; Rudy Leon De Wilde
Journal:  J Obstet Gynaecol India       Date:  2015-09-14

3.  Technology for minimal access surgery. Interview by Judy Jones.

Authors:  A Cuschieri
Journal:  BMJ       Date:  1999-11-13

4.  Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT).

Authors:  F J Kim; M F Chammas; E Gewehr; M Morihisa; F Caldas; E Hayacibara; M Baptistussi; F Meyer; A C Martins
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

5.  Evaluation of emissivity and temperature profile of laparoscopic ultrasonic devices (blades and passive jaws).

Authors:  Fernando J Kim; David Sehrt; Rodrigo Donalisio da Silva; Diedra Gustafson; Leticia Nogueira; Wilson R Molina
Journal:  Surg Endosc       Date:  2014-08-27       Impact factor: 4.584

6.  Ultrasonic versus monopolar energy-based surgical devices in terms of surgical smoke and lateral thermal damage (ULMOST): a randomized controlled trial.

Authors:  Chahien Choi; In-Gu Do; Taejong Song
Journal:  Surg Endosc       Date:  2018-04-09       Impact factor: 4.584

Review 7.  Common uses and cited complications of energy in surgery.

Authors:  Ganesh Sankaranarayanan; Rajeswara R Resapu; Daniel B Jones; Steven Schwaitzberg; Suvranu De
Journal:  Surg Endosc       Date:  2013-04-23       Impact factor: 4.584

8.  Comparison of lateral thermal damage of the human peritoneum using monopolar diathermy, Harmonic scalpel and LigaSure.

Authors:  Nikica Družijanić; Zenon Pogorelić; Zdravko Perko; Ivana Mrklić; Snježana Tomić
Journal:  Can J Surg       Date:  2012-10       Impact factor: 2.089

9.  Ureteral injury due to a Harmonic scalpel during laparoscopic salpingo-oophorectomy.

Authors:  Patrick F Vetere; Costas Apostolis
Journal:  JSLS       Date:  2010-04-21       Impact factor: 2.172

10.  Rupture of the spleen with the harmonic scalpel: case report of an unexplained complication.

Authors:  John E Morrison; Volker R Jacobs
Journal:  JSLS       Date:  2007 Apr-Jun       Impact factor: 2.172

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.