Literature DB >> 25139115

Towards a solution of the wires' slippage problem of the Ilizarov external fixator.

C Bairaktari1, G Athanassiou, E Panagiotopoulos, D Deligianni.   

Abstract

Clinical experience has indicated that many complications during treatment with the Ilizarov method, and mainly tract infection, are related to decreased wire tension. The aim of this work was to evaluate biomechanically a novel wire tensioning and clamping system that will minimise or even diminish the reduction of the wire pretension during treatment. The proposed approach is based on threading of the wire end in a sufficient length. The wire pretension is applied by twisting a nut on the threaded part of the wires against the ring and is recorded by an incorporated force sensor. For biomechanical evaluation, the frame, consisting of a polyethylene bar, simulating the bone fragment, suspended on two rings, was subjected to a dynamic load of 0-800 N at a frequency of 0.5 Hz. After dynamic loading for 20 min, loss of the initial wire pretension for the novel clamping system ranged between 12 and 16%. The average loss for conventionally clamped wires was 75%. The advantages of the novel clamping system were the much greater ability to sustain the transverse load and the easy and effectual wire re-tensioning. Although wire slippage has been avoided with the novel system, wire material yield is still responsible for a pretension loss.

Entities:  

Mesh:

Year:  2014        PMID: 25139115     DOI: 10.1007/s00590-014-1518-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  23 in total

1.  The biomechanics of wire fixation in the Ilizarov system.

Authors:  M M Mullins; A W Davidson; David Goodier; M Barry
Journal:  Injury       Date:  2003-02       Impact factor: 2.586

2.  Wire tension versus wire frequency: an experimental Ilizarov frame study.

Authors:  Valentina La Russa; Bjørn Skallerud; Jomar Klaksvik; Olav A Foss
Journal:  J Biomech       Date:  2010-05-15       Impact factor: 2.712

3.  The Ilizarov external fixator: what remains of the wire pretension after dynamic loading?

Authors:  A J S Renard; B G Schutte; N Verdonschot; A van Kampen
Journal:  Clin Biomech (Bristol, Avon)       Date:  2005-10-06       Impact factor: 2.063

4.  Relationship between locking-bolt torque and load pre-tension in the Ilizarov frame.

Authors:  N A Osei; B M Bradley; P Culpan; J B Mitchell; M Barry; K E Tanner
Journal:  Injury       Date:  2006-10       Impact factor: 2.586

5.  Why fine-wire fixators work: an analysis of pressure distribution at the wire-bone interface.

Authors:  T N Board; L Yang; M Saleh
Journal:  J Biomech       Date:  2006-02-07       Impact factor: 2.712

6.  Stiffness characteristics of the circular Ilizarov device as opposed to conventional external fixators.

Authors:  B Gasser; B Boman; D Wyder; E Schneider
Journal:  J Biomech Eng       Date:  1990-02       Impact factor: 2.097

Review 7.  Ilizarov principles of deformity correction.

Authors:  B Spiegelberg; T Parratt; S K Dheerendra; W S Khan; R Jennings; D R Marsh
Journal:  Ann R Coll Surg Engl       Date:  2010-03       Impact factor: 1.891

8.  Mechanical stress on tensioned wires at direct and indirect loading: a biomechanical study on the Ilizarov external fixator.

Authors:  Jan Gessmann; Birger Jettkant; Thomas Armin Schildhauer; Dominik Seybold
Journal:  Injury       Date:  2011-03-09       Impact factor: 2.586

9.  Avoiding the material nonlinearity in an external fixation device.

Authors:  Guigen Zhang
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-08       Impact factor: 2.063

10.  Rapid pre-tension loss in the Ilizarov external fixator: an in vitro study.

Authors:  René Aquarius; Albert Van Kampen; Nico Verdonschot
Journal:  Acta Orthop       Date:  2007-10       Impact factor: 3.717

View more
  1 in total

Review 1.  An engineering review of external fixators.

Authors:  P L N Fernando; Aravinda Abeygunawardane; Pci Wijesinghe; Parakrama Dharmaratne; Pujitha Silva
Journal:  Med Eng Phys       Date:  2021-11-04       Impact factor: 2.242

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.