Stiffness characteristics of the circular Ilizarov device as opposed to conventional external fixators.

B Gasser1, B Boman, D Wyder, E Schneider.   

Abstract

Ilizarov proposes the use of a special circular fixation device for treatment of bone defects and nonunions or for limb lengthening. Supposition was that the success of this method has to do with the specific mechanical behavior of the device. This behavior is a result of the configuration of the fixation elements. Therefore, a mechanical study of the sensitivity of the circular compression and distraction device (CDD) to configuration parameters was performed. The CDD was found to exhibit a nonlinear stiffness behavior, in particular under axial load. This may be favorable for the induction and tolerance of bone formation. Among the different parameters tested the ring radius was the most important with respect to stiffness. In general, the stiffness of the CDD allows adjustment during postoperative management. In magnitude, it is equal or lower when compared to other fixator types.

Entities:  

Mesh:

Year:  1990        PMID: 2308299     DOI: 10.1115/1.2891120

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  15 in total

1.  Limb lengthening and three-dimensional deformity corrections. A retrospective clinical study.

Authors:  K Korzinek; S Tepic; S M Perren
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

2.  The mechanics of external fixation.

Authors:  Austin T Fragomen; S Robert Rozbruch
Journal:  HSS J       Date:  2007-02

3.  Circular external fixation frames with divergent half pins: a pilot biomechanical study.

Authors:  Christopher Lenarz; Gary Bledsoe; J Tracy Watson
Journal:  Clin Orthop Relat Res       Date:  2008-09-18       Impact factor: 4.176

Review 4.  Ilizarov principles of deformity correction.

Authors:  B Spiegelberg; T Parratt; S K Dheerendra; W S Khan; R Jennings; D R Marsh
Journal:  Ann R Coll Surg Engl       Date:  2010-03       Impact factor: 1.891

5.  Towards a solution of the wires' slippage problem of the Ilizarov external fixator.

Authors:  C Bairaktari; G Athanassiou; E Panagiotopoulos; D Deligianni
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-08-20

6.  [Mechanobiology of fracture healing part 2 : Relevance for internal fixation of fractures].

Authors:  L Claes
Journal:  Unfallchirurg       Date:  2017-01       Impact factor: 1.000

7.  What Are the Biomechanical Properties of the Taylor Spatial Frame™?

Authors:  Daniel J Henderson; Jeremy L Rushbrook; Paul J Harwood; Todd D Stewart
Journal:  Clin Orthop Relat Res       Date:  2016-11-28       Impact factor: 4.176

8.  Interfragmentary movements in the early phase of healing in distraction and correction osteotomies stabilized with ring fixators.

Authors:  Georg N Duda; Simon Sporrer; Michael Sollmann; Jan E Hoffmann; Jean-Pierre Kassi; Cyrus Khodadadyan; Michael Raschke
Journal:  Langenbecks Arch Surg       Date:  2003-01-30       Impact factor: 3.445

9.  Lengthening of congenital limb length discrepancy using callotasis: early experience of the Hospital for Sick Children.

Authors:  N Maffulli; R C Pattinson; J A Fixsen
Journal:  Ann R Coll Surg Engl       Date:  1993-03       Impact factor: 1.891

10.  Does partial weight bearing unload a healing bone in external ring fixation?

Authors:  Georg N Duda; Barbara Bartmeyer; Simon Sporrer; Wiliam R Taylor; Michael Raschke; Norbert P Haas
Journal:  Langenbecks Arch Surg       Date:  2003-09-13       Impact factor: 3.445

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.