Literature DB >> 25004506

Techniques and evaluation from a cross-platform imaging comparison of quantitative ultrasound parameters in an in vivo rodent fibroadenoma model.

Lauren A Wirtzfeld, Kibo Nam, Yassin Labyed, Goutam Ghoshal, Alexander Haak, Ellora Sen-Gupta, Zhi He, Nathaniel R Hirtz, Rita J Miller, Sandhya Sarwate, Douglas G Simpson, James A Zagzebski, Timothy A Bigelow, Michael Oelze, Timothy J Hall, William D O'Brien.   

Abstract

This contribution demonstrates that quantitative ultrasound (QUS) capabilities are platform independent, using an in vivo model. Frequency-dependent attenuation estimates, backscatter coefficient, and effective scatterer diameter estimates are shown to be comparable across four different ultrasound imaging systems with varied processing techniques. The backscatter coefficient (BSC) is a fundamental material property from which several QUS parameters are estimated; therefore, consistent BSC estimates among different systems must be demonstrated. This study is an intercomparison of BSC estimates acquired by three research groups (UIUC, UW, ISU) from four in vivo spontaneous rat mammary fibroadenomas using three clinical array systems and a single-element laboratory scanner system. Because of their highly variable backscatter properties, fibroadenomas provided an extreme test case for BSC analysis, and the comparison is across systems for each tumor, not across the highly heterogeneous tumors. RF echo data spanning the 1 to 12 MHz frequency range were acquired in three dimensions from all animals using each system. Each research group processed their RF data independently, and the resulting attenuation, BSC, and effective scatterer diameter (ESD) estimates were compared. The attenuation estimates across all systems showed the same trends and consistently fit the power-law dependence on frequency. BSCs varied among the multiple slices of data acquired by each transducer, with variations between transducers being of a similar magnitude as those from slice to slice. Variation between BSC estimates was assessed via functional signal-to-noise ratios derived from backscatter data. These functional signal-to-noise ratios indicated that BSC versus frequency variations between systems ranged from negligible compared with the noise level to roughly twice the noise level. The corresponding functional analysis of variance (fANOVA) indicated statistically significant differences between BSC curves from different systems. However, root mean squared difference errors of the BSC values (in decibels) between different transducers and imaging platforms were less than half of the BSC magnitudes in most cases. Statistical comparison of the effective scatterer diameter (ESD) estimates resulted in no significant differences in estimates from three of the four transducers used for those estimates, demonstrating agreement among estimates based on the BSC. This technical advance demonstrates that these in vivo measurements can be made in a system-independent manner; the necessary step toward clinical implementation of the technology.

Entities:  

Mesh:

Year:  2013        PMID: 25004506      PMCID: PMC4090611          DOI: 10.1109/TUFFC.2013.2711

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  20 in total

1.  Role of advanced 2 and 3-dimensional ultrasound for detecting prostate cancer.

Authors:  K C Balaji; William R Fair; Ernst J Feleppa; Christopher R Porter; Harold Tsai; Tian Liu; Andrew Kalisz; Stella Urban; John Gillespie
Journal:  J Urol       Date:  2002-12       Impact factor: 7.450

2.  Examination of cancer in mouse models using high-frequency quantitative ultrasound.

Authors:  Michael L Oelze; James F Zachary
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

3.  Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gels.

Authors:  Ernest L Madsen; Maritza A Hobson; Hairong Shi; Tomy Varghese; Gary R Frank
Journal:  Ultrasound Med Biol       Date:  2006-02       Impact factor: 2.998

4.  Relationship of ultrasonic spectral parameters to features of tissue microstructure.

Authors:  F L Lizzi; M Ostromogilsky; E J Feleppa; M C Rorke; M M Yaremko
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1987       Impact factor: 2.725

5.  On the estimation of backscatter coefficients using single-element focused transducers.

Authors:  Roberto J Lavarello; Goutam Ghoshal; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2011-05       Impact factor: 1.840

6.  Ultrasonic measurement of glomerular diameters in normal adult humans.

Authors:  T J Hall; M F Insana; L A Harrison; G G Cox
Journal:  Ultrasound Med Biol       Date:  1996       Impact factor: 2.998

7.  Acoustic coupling from a focused transducer to a flat plate and back to the transducer.

Authors:  X Chen; K Q Schwarz; K J Parker
Journal:  J Acoust Soc Am       Date:  1994-06       Impact factor: 1.840

8.  Cross-imaging platform comparison of ultrasonic backscatter coefficient measurements of live rat tumors.

Authors:  Lauren A Wirtzfeld; Goutam Ghoshal; Zachary T Hafez; Kibo Nam; Yassin Labyed; Janelle J Anderson; Maria-Teresa Herd; Alexander Haak; Zhi He; Rita J Miller; Sandhya Sarwate; Douglas G Simpson; James A Zagzebski; Timothy A Bigelow; Michael L Oelze; Timothy J Hall; William D O'Brien
Journal:  J Ultrasound Med       Date:  2010-07       Impact factor: 2.153

9.  Ultrasonic attenuation and backscatter coefficient estimates of rodent-tumor-mimicking structures: comparison of results among clinical scanners.

Authors:  Kibo Nam; Ivan M Rosado-Mendez; Lauren A Wirtzfeld; Alexander D Pawlicki; Viksit Kumar; Ernest L Madsen; Goutam Ghoshal; Roberto J Lavarello; Michael L Oelze; Timothy A Bigelow; James A Zagzebski; William D O'Brien; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2011-10       Impact factor: 1.578

10.  Interlaboratory comparison of backscatter coefficient estimates for tissue-mimicking phantoms.

Authors:  Janelle J Anderson; Maria-Teresa Herd; Michael R King; Alexander Haak; Zachary T Hafez; Jun Song; Michael L Oelze; Ernest L Madsen; James A Zagzebski; William D O'Brien; Timothy J Hall
Journal:  Ultrason Imaging       Date:  2010-01       Impact factor: 1.578

View more
  11 in total

1.  Quantitative Ultrasound for Monitoring High-Intensity Focused Ultrasound Treatment In Vivo.

Authors:  Goutam Ghoshal; Jeremy P Kemmerer; Chandra Karunakaran; Rita J Miller; Michael L Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-01-14       Impact factor: 2.725

2.  A Method for Stereological Determination of the Structure Function From Histological Sections of Isotropic Scattering Media.

Authors:  Aiguo Han
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-06       Impact factor: 2.725

3.  Structure function for high-concentration biophantoms of polydisperse scatterer sizes.

Authors:  Aiguo Han; William O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

Review 4.  The mechanical role of the cervix in pregnancy.

Authors:  Kristin M Myers; Helen Feltovich; Edoardo Mazza; Joy Vink; Michael Bajka; Ronald J Wapner; Timothy J Hall; Michael House
Journal:  J Biomech       Date:  2015-03-11       Impact factor: 2.712

5.  A Quantitative Ultrasound-Based Multi-Parameter Classifier for Breast Masses.

Authors:  Haidy G Nasief; Ivan M Rosado-Mendez; James A Zagzebski; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2019-04-26       Impact factor: 2.998

6.  Robust probabilistic classification applicable to irregularly sampled functional data.

Authors:  Yeonjoo Park; Douglas G Simpson
Journal:  Comput Stat Data Anal       Date:  2018-08-11       Impact factor: 1.681

7.  A Phantom-Based Assessment of Repeatability and Reproducibility of Transvaginal Quantitative Ultrasound.

Authors:  Shi Chen; Barbara L McFarlin; Barbara T Meagher; Tara A Peters; Douglas G Simpson; William D O'Brien; Aiguo Han
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-14       Impact factor: 2.725

8.  Quantitative Ultrasound Comparison of MAT and 4T1 Mammary Tumors in Mice and Rats Across Multiple Imaging Systems.

Authors:  Lauren A Wirtzfeld; Goutam Ghoshal; Ivan M Rosado-Mendez; Kibo Nam; Yeonjoo Park; Alexander D Pawlicki; Rita J Miller; Douglas G Simpson; James A Zagzebski; Michael L Oelze; Timothy J Hall; William D O'Brien
Journal:  J Ultrasound Med       Date:  2015-08       Impact factor: 2.153

9.  Acoustic Properties of Breast Fat.

Authors:  Haidy Gerges Nasief; Ivan M Rosado-Mendez; James A Zagzebski; Timothy J Hall
Journal:  J Ultrasound Med       Date:  2015-10-07       Impact factor: 2.153

10.  Structure Function Estimated From Histological Tissue Sections.

Authors:  Aiguo Han; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-25       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.