Literature DB >> 31217100

A Phantom-Based Assessment of Repeatability and Reproducibility of Transvaginal Quantitative Ultrasound.

Shi Chen, Barbara L McFarlin, Barbara T Meagher, Tara A Peters, Douglas G Simpson, William D O'Brien, Aiguo Han.   

Abstract

This article evaluated the repeatability and reproducibility (R&R) of quantitative ultrasound (QUS) biomarkers attenuation coefficient (AC) and backscatter coefficient (BSC) in transvaginal QUS reference phantoms for obstetric applications. Five phantoms were scanned by three sonographers according to the scanning protocol. Each sonographer scanned each phantom with four transvaginal transducers of the same model (MC9-4) and three probe cover types (latex cover, nonlatex cover, and no cover). The AC and BSC were estimated by using a reference phantom method. The R&R analysis was performed for the frequency-averaged AC and logBSC (= 10log10BSC) (5.4-5.8 MHz) by using three-factor random effects Analysis of Variance with interaction. The total R&R variabilities for AC and logBSC are small (AC: 0.042-0.065 dB/cm-MHz; logBSC: 0.50-0.68 dB), indicating high measurement precision. These values are small compared to the ranges of AC (0.28-0.99 dB/cm-MHz) and logBSC (-33.16 to -20.35 dB) of the five phantoms. The AC and logBSC biomarkers measured on transvaginal QUS phantoms using the reference phantom method are repeatable, and reproducible between sonographers, transducers, and probe covers.

Entities:  

Mesh:

Year:  2019        PMID: 31217100      PMCID: PMC6774614          DOI: 10.1109/TUFFC.2019.2921925

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  15 in total

1.  Metrology Standards for Quantitative Imaging Biomarkers.

Authors:  Daniel C Sullivan; Nancy A Obuchowski; Larry G Kessler; David L Raunig; Constantine Gatsonis; Erich P Huang; Marina Kondratovich; Lisa M McShane; Anthony P Reeves; Daniel P Barboriak; Alexander R Guimaraes; Richard L Wahl
Journal:  Radiology       Date:  2015-08-12       Impact factor: 11.105

2.  An ultrasound research interface for a clinical system.

Authors:  Shelby S Brunke; Michael F Insana; Jeremy J Dahl; Christian Hansen; Mohammad Ashfaq; Helmut Ermert
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-01       Impact factor: 2.725

3.  A Pilot Comparative Study of Quantitative Ultrasound, Conventional Ultrasound, and MRI for Predicting Histology-Determined Steatosis Grade in Adult Nonalcoholic Fatty Liver Disease.

Authors:  Jeremy S Paige; Gregory S Bernstein; Elhamy Heba; Eduardo A C Costa; Marilia Fereirra; Tanya Wolfson; Anthony C Gamst; Mark A Valasek; Grace Y Lin; Aiguo Han; John W Erdman; William D O'Brien; Michael P Andre; Rohit Loomba; Claude B Sirlin
Journal:  AJR Am J Roentgenol       Date:  2017-03-07       Impact factor: 3.959

4.  Development of an ultrasonic method to detect cervical remodeling in vivo in full-term pregnant women.

Authors:  Barbara L McFarlin; Jennifer Balash; Viksit Kumar; Timothy A Bigelow; Xavier Pombar; Jacques S Abramowicz; William D O'Brien
Journal:  Ultrasound Med Biol       Date:  2015-05-23       Impact factor: 2.998

5.  The emerging science of quantitative imaging biomarkers terminology and definitions for scientific studies and regulatory submissions.

Authors:  Larry G Kessler; Huiman X Barnhart; Andrew J Buckler; Kingshuk Roy Choudhury; Marina V Kondratovich; Alicia Toledano; Alexander R Guimaraes; Ross Filice; Zheng Zhang; Daniel C Sullivan
Journal:  Stat Methods Med Res       Date:  2014-06-11       Impact factor: 3.021

6.  Repeatability and Reproducibility of a Clinically Based QUS Phantom Study and Methodologies.

Authors:  Aiguo Han; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-07-09       Impact factor: 2.725

7.  Robust probabilistic classification applicable to irregularly sampled functional data.

Authors:  Yeonjoo Park; Douglas G Simpson
Journal:  Comput Stat Data Anal       Date:  2018-08-11       Impact factor: 1.681

8.  Inter-platform reproducibility of ultrasonic attenuation and backscatter coefficients in assessing NAFLD.

Authors:  Aiguo Han; Yingzhen N Zhang; Andrew S Boehringer; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien
Journal:  Eur Radiol       Date:  2019-02-19       Impact factor: 5.315

9.  Noninvasive Diagnosis of Nonalcoholic Fatty Liver Disease and Quantification of Liver Fat Using a New Quantitative Ultrasound Technique.

Authors:  Steven C Lin; Elhamy Heba; Tanya Wolfson; Brandon Ang; Anthony Gamst; Aiguo Han; John W Erdman; William D O'Brien; Michael P Andre; Claude B Sirlin; Rohit Loomba
Journal:  Clin Gastroenterol Hepatol       Date:  2014-12-03       Impact factor: 11.382

10.  Inter-sonographer reproducibility of quantitative ultrasound outcomes and shear wave speed measured in the right lobe of the liver in adults with known or suspected non-alcoholic fatty liver disease.

Authors:  Aiguo Han; Yassin Labyed; Ethan Z Sy; Andrew S Boehringer; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien
Journal:  Eur Radiol       Date:  2018-06-04       Impact factor: 5.315

View more
  1 in total

1.  Ultra-high frequency ultrasound as a clinical adjunct for imaging the oral cavity: added value of quantitative analysis.

Authors:  Celia R DeJohn; Mukund Seshadri
Journal:  Dentomaxillofac Radiol       Date:  2020-10       Impact factor: 2.419

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.