Literature DB >> 24982554

Reliability of manual measurements of corneal thickness obtained from healthy canine eyes using spectral-domain optical coherence tomography (SD-OCT).

Anthony F Alario1, Christopher G Pirie1.   

Abstract

The purpose of this study was to manually measure corneal thickness in canine eyes using a spectral-domain optical coherence tomography (SD-OCT) device and to assess intra- and inter-observer reliability of this technique. Twenty healthy dogs with a mean age of 4.7 y were examined. A 6-mm corneal pachymetry protocol was carried out by 1 operator using 1 SD-OCT device in both eyes of each animal. Measurements were obtained manually and in duplicate by 2 independent investigators (> 24 h apart), using the built-in caliper function. Measurements included epithelial thickness (ET), non-epithelial thickness (NET), and central corneal thickness (CCT). The overall mean ET, NET, and CCT for all eyes examined were 72.3 ± 4.6 μm, 538.9 ± 42.5 μm, and 611.2 ± 40.3 μm, respectively. There was no significant difference in ET, NET, or CCT based on the eye examined [oculus dexter (OD) versus oculus sinister (OS)], age, or gender of the animal. There was no significant difference in replicate measurements of ET, NET, or CCT done by the same operator, although a small but significant difference was noted between operators for ET measurements only. The mean difference in ET between operators was 0.6 μm (P = 0.03). The coefficient of variation ranged from 0.5% to 9.27% and intraclass correlation coefficient ranged from 0.35 to 0.97. Based on these results, manual measurements of corneal thickness in canine eyes using a portable SD-OCT device provided ET, NET, and CCT measurements with clinically acceptable intra- and inter-observer reliability.

Entities:  

Mesh:

Year:  2014        PMID: 24982554      PMCID: PMC4068414     

Source DB:  PubMed          Journal:  Can J Vet Res        ISSN: 0830-9000            Impact factor:   1.310


  17 in total

1.  Precision of high definition spectral-domain optical coherence tomography for measuring central corneal thickness.

Authors:  María E Correa-Pérez; Alberto López-Miguel; Silvia Miranda-Anta; Darío Iglesias-Cortiñas; Jorge L Alió; Miguel J Maldonado
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-04-06       Impact factor: 4.799

2.  The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography.

Authors:  Sokpheaktra Sin; Trefford L Simpson
Journal:  Optom Vis Sci       Date:  2006-06       Impact factor: 1.973

Review 3.  Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomography.

Authors:  Winifred Nolan
Journal:  Curr Opin Ophthalmol       Date:  2008-03       Impact factor: 3.761

4.  Correlation, agreement, and Bland-Altman analysis: statistical analysis of method comparison studies.

Authors:  Catey Bunce
Journal:  Am J Ophthalmol       Date:  2009-07       Impact factor: 5.258

5.  Epithelial thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2008-06       Impact factor: 3.573

6.  Central corneal thickness measurements with Fourier-domain optical coherence tomography versus ultrasonic pachymetry and rotating Scheimpflug camera.

Authors:  Akihiro Ishibazawa; Sho Igarashi; Kazuomi Hanada; Taiji Nagaoka; Satoshi Ishiko; Haruna Ito; Akitoshi Yoshida
Journal:  Cornea       Date:  2011-06       Impact factor: 2.651

7.  Ocular surface epithelial thickness evaluation with spectral-domain optical coherence tomography.

Authors:  Marlène Francoz; Issouf Karamoko; Christophe Baudouin; Antoine Labbé
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-11-25       Impact factor: 4.799

8.  Effect of central corneal thickness on intraocular pressure with the rebound tonometer and the applanation tonometer in normal dogs.

Authors:  Young-Woo Park; Man-Bok Jeong; Tae-Hyun Kim; Jae-Sang Ahn; Jeong-Taek Ahn; Shin-Ae Park; Se-Eun Kim; Kangmoon Seo
Journal:  Vet Ophthalmol       Date:  2011-05       Impact factor: 1.644

9.  Central corneal thickness measurements in normal dogs: a comparison between ultrasound pachymetry and optical coherence tomography.

Authors:  Anthony F Alario; Christopher G Pirie
Journal:  Vet Ophthalmol       Date:  2013-06-14       Impact factor: 1.644

10.  Thickness mapping of the cornea and epithelium using optical coherence tomography.

Authors:  Sameena Haque; Lyndon Jones; Trefford Simpson
Journal:  Optom Vis Sci       Date:  2008-10       Impact factor: 1.973

View more
  2 in total

1.  Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease.

Authors:  A L Hoehn; S M Thomasy; P H Kass; T Horikawa; M Samuel; O R Shull; K A Stewart; C J Murphy
Journal:  Vet J       Date:  2018-10-30       Impact factor: 2.688

2.  In vivo evaluation of the cornea and conjunctiva of the normal laboratory beagle using time- and Fourier-domain optical coherence tomography and ultrasound pachymetry.

Authors:  Ann R Strom; Dennis E Cortés; Carol A Rasmussen; Sara M Thomasy; Kim McIntyre; Shwu-Fei Lee; Philip H Kass; Mark J Mannis; Christopher J Murphy
Journal:  Vet Ophthalmol       Date:  2015-02-10       Impact factor: 1.644

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.