Literature DB >> 18301284

Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomography.

Winifred Nolan1.   

Abstract

PURPOSE OF REVIEW: Recent advances in ocular imaging have included high-resolution techniques for visualizing the anterior segment and angle structures. This review will describe the two main anterior segment imaging modalities and summarize their applications, strengths and weaknesses. RECENT
FINDINGS: Ultrasound biomicroscopy and more recently anterior segment optical coherence tomography are imaging modalities that can be used to obtain two-dimensional images of the angle and surrounding structures. Ultrasound biomicroscopy has the advantage of being able to illustrate the ciliary body and therefore give clinicians information on nonpupil block mechanisms of primary angle closure and also diagnose other abnormalities such as cyclodialysis clefts. Anterior segment optical coherence tomography is a noncontact and rapid method of imaging the angle and anterior segment that has great potential in the diagnosis and follow-up of patients with angle closure. This article will discuss these and other applications and compare and contrast the two technologies.
SUMMARY: Rapid advances in anterior segment imaging are enlightening clinicians and researchers to the importance in making the diagnosis of primary angle closure, trying to establish underlying causal mechanisms, and evaluating treatments. Although they do not replace conventional angle and anterior segment examination, they hold great potential for the future.

Entities:  

Mesh:

Year:  2008        PMID: 18301284     DOI: 10.1097/ICU.0b013e3282f40bba

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  31 in total

Review 1.  Cyclodialysis: an update.

Authors:  Julio González-Martín-Moro; Inés Contreras-Martín; Francisco José Muñoz-Negrete; Fernando Gómez-Sanz; Jesús Zarallo-Gallardo
Journal:  Int Ophthalmol       Date:  2016-07-08       Impact factor: 2.031

2.  Ultrasound biomicroscopic evaluation of anterior segment cysts as a risk factor for ocular hypertension and closure angle glaucoma.

Authors:  Abdurrahim Dusak; Mehmet Baykara; Guven Ozkaya; Cuneyt Erdogan; Hikmet Ozcetin; Ercan Tuncel
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

3.  Long-term outcomes following the surgical repair of traumatic cyclodialysis clefts.

Authors:  P Agrawal; P Shah
Journal:  Eye (Lond)       Date:  2013-08-30       Impact factor: 3.775

Review 4.  Optical coherence tomography: history, current status, and laboratory work.

Authors:  Michelle L Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Larry Kagemann; Juan Xu; Lindsey S Folio; Joel S Schuman
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-04-14       Impact factor: 4.799

5.  Reliability of manual measurements of corneal thickness obtained from healthy canine eyes using spectral-domain optical coherence tomography (SD-OCT).

Authors:  Anthony F Alario; Christopher G Pirie
Journal:  Can J Vet Res       Date:  2014-07       Impact factor: 1.310

6.  [Ultrasound diagnostics in ophthalmology (standardized echography): part 2: diseases of the orbit - ultrasound biomicroscopy diagnostics].

Authors:  G Hasenfratz; C Mardin
Journal:  Ophthalmologe       Date:  2014-11       Impact factor: 1.059

7.  Effect of Laser Peripheral Iridotomy on Anterior Chamber Angle Anatomy in Primary Angle Closure Spectrum Eyes.

Authors:  Seema Kansara; Lauren S Blieden; Alice Z Chuang; Laura A Baker; Nicholas P Bell; Kimberly A Mankiewicz; Robert M Feldman
Journal:  J Glaucoma       Date:  2016-05       Impact factor: 2.503

8.  Comparison of anterior section parameters using anterior segment optical coherence tomography and ultrasound biomicroscopy in myopic patients after ICL implantation.

Authors:  Jing Zhang; Hui-Hui Luo; Jing Zhuang; Ke-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

9.  Changes in anterior chamber configuration after cataract surgery as measured by anterior segment optical coherence tomography.

Authors:  Martha Kim; Ki Ho Park; Tae-Woo Kim; Dong Myung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

Review 10.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.