Literature DB >> 16772894

The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography.

Sokpheaktra Sin1, Trefford L Simpson.   

Abstract

PURPOSE: The purpose of this study is to examine within and between session repeatability of clinical optical coherence tomography (OCT) imaging for anterior segment morphometry.
METHODS: Images of the corneal apex of each eye in 18 subjects were obtained using a Humphrey Zeiss OCT imager. Subjects viewed a target positioned to ensure that scans were orthogonal to the ocular surface and each image, consisting of 100 adjacent sagittal scans, analyzed using custom software. Repeatability data were analyzed using intraclass correlation coefficients (ICCs), correlation coefficient of concordance (CCC, perfect test-retest agreement ICC or CCC = 1.0), and coefficients of repeatability (COR, 95% confidence interval of test-retest differences). To account for each eye, the multivariate repeatability statistic Iota was estimated.
RESULTS: Mean central corneal and epithelial thickness of 32 eyes (OD and OS combined) is 536 +/- 26 microm (standard deviation [SD]) and 52 +/- 3 microm (SD) with 5th and 95th percentile thicknesses of 507 and 591 microm for central cornea and 48 and 57 microm for central epithelial. Worst case within session repeatability was defined as repeatability between images with greatest differences in mean thickness within a session. Corneal thickness worst case ICC was 0.95 and COR was +/- 9.98 microm. Epithelium worst case ICC was 0.36, CCC was 0.12, and COR was +/- 11.11 microm. First image between session corneal thickness had an ICC = 0.98 and a COR = 10.83 microm, whereas epithelium ICC = 0.38, CCC = 0.37, and COR was +/- 12.84 microm. When we compared the average of the first three tests with the first three retest images, corneal ICC was 0.98 and COR was +/- 10.64 microm and epithelium ICC = 0.73, CCC = 0.72, and COR was +/- 6.53 microm. Iota (multivariate repeatability, using eye as a factor) for the cornea was at least 0.96 (worst case) and increased to at least 0.98 when within-session image data were averaged. Iota for epithelium measures ranged from 0.29 when first images were compared with 0.57 when within-session image data were averaged.
CONCLUSIONS: There is very good repeatability of corneal thickness measurement using OCT; even the worst case measurements are similar between sessions. On the other hand, this is not the case for epithelium measurements, and if multiple images within a session are acquired, the worst case results demonstrate how important it is to optimize each OCT scan and also average multiple scans to maximize intersession repeatability.

Entities:  

Mesh:

Year:  2006        PMID: 16772894     DOI: 10.1097/01.opx.0000221388.26031.23

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  27 in total

1.  Reliability of manual measurements of corneal thickness obtained from healthy canine eyes using spectral-domain optical coherence tomography (SD-OCT).

Authors:  Anthony F Alario; Christopher G Pirie
Journal:  Can J Vet Res       Date:  2014-07       Impact factor: 1.310

2.  Evaluation of corneal epithelial and stromal thickness in keratoconus using spectral-domain optical coherence tomography.

Authors:  Naoyuki Maeda; Tomoya Nakagawa; Ritsuko Higashiura; Mutsumi Fuchihata; Shizuka Koh; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2014-07-12       Impact factor: 2.447

3.  Assessment of corneal epithelial thickness in dry eye patients.

Authors:  Xinhan Cui; Jiaxu Hong; Fei Wang; Sophie X Deng; Yujing Yang; Xiaoyu Zhu; Dan Wu; Yujin Zhao; Jianjiang Xu
Journal:  Optom Vis Sci       Date:  2014-12       Impact factor: 1.973

4.  Vertical and horizontal corneal epithelial thickness profiles determined by ultrahigh resolution optical coherence tomography.

Authors:  Chixin Du; Jianhua Wang; Lele Cui; Meixiao Shen; Yimin Yuan
Journal:  Cornea       Date:  2012-09       Impact factor: 2.651

5.  Single-Step Transepithelial Photorefractive Keratectomy in Low to Moderate Myopia: A One-Year Follow-Up Study.

Authors:  Shereef M Abdelwahab; Mohamed Hany Salem; Maha A Elfayoumi
Journal:  Clin Ophthalmol       Date:  2021-08-09

6.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

7.  Corneal epithelial thickness mapping by Fourier-domain optical coherence tomography in normal and keratoconic eyes.

Authors:  Yan Li; Ou Tan; Robert Brass; Jack L Weiss; David Huang
Journal:  Ophthalmology       Date:  2012-08-20       Impact factor: 12.079

8.  Entire thickness profiles of the epithelium and contact lens in vivo imaged with high-speed and high-resolution optical coherence tomography.

Authors:  Aizhu Tao; Yilei Shao; Hong Jiang; Yufeng Ye; Fan Lu; Meixiao Shen; Dexi Zhu; Jianhua Wang
Journal:  Eye Contact Lens       Date:  2013-09       Impact factor: 2.018

9.  Repeatability of corneal epithelial thickness measurements using Fourier-domain optical coherence tomography in normal and post-LASIK eyes.

Authors:  Xingxuan Jack Ma; Li Wang; Douglas D Koch
Journal:  Cornea       Date:  2013-12       Impact factor: 2.651

10.  Anterior segment optical coherence tomography: assisted topographic corneal epithelial thickness distribution imaging of a keratoconus patient.

Authors:  A John Kanellopoulos; George Asimellis
Journal:  Case Rep Ophthalmol       Date:  2013-04-18