Literature DB >> 19033085

Wavelet based noise reduction in CT-images using correlation analysis.

Anja Borsdorf1, Rainer Raupach, Thomas Flohr, Joachim Hornegger.   

Abstract

The projection data measured in computed tomography (CT) and, consequently, the slices reconstructed from these data are noisy. We present a new wavelet based structure-preserving method for noise reduction in CT-images that can be used in combination with different reconstruction methods. The approach is based on the assumption that data can be decomposed into information and temporally uncorrelated noise. In CT two spatially identical images can be generated by reconstructions from disjoint subsets of projections: using the latest generation dual source CT-scanners one image can be reconstructed from the projections acquired at the first, the other image from the projections acquired at the second detector. For standard CT-scanners the two images can be generated by splitting up the set of projections into even and odd numbered projections. The resulting images show the same information but differ with respect to image noise. The analysis of correlations between the wavelet representations of the input images allows separating information from noise down to a certain signal-to-noise level. Wavelet coefficients with small correlation are suppressed, while those with high correlations are assumed to represent structures and are preserved. The final noise-suppressed image is reconstructed from the averaged and weighted wavelet coefficients of the input images. The proposed method is robust, of low complexity and adapts itself to the noise in the images. The quantitative and qualitative evaluation based on phantom as well as real clinical data showed, that high noise reduction rates of around 40% can be achieved without noticeable loss of image resolution.

Mesh:

Year:  2008        PMID: 19033085     DOI: 10.1109/TMI.2008.923983

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  22 in total

1.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Achieving routine submillisievert CT scanning: report from the summit on management of radiation dose in CT.

Authors:  Cynthia H McCollough; Guang Hong Chen; Willi Kalender; Shuai Leng; Ehsan Samei; Katsuyuki Taguchi; Ge Wang; Lifeng Yu; Roderic I Pettigrew
Journal:  Radiology       Date:  2012-06-12       Impact factor: 11.105

4.  Adaptive noise correction of dual-energy computed tomography images.

Authors:  Rafael Simon Maia; Christian Jacob; Amy K Hara; Alvin C Silva; William Pavlicek; J Ross Mitchell
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-10-13       Impact factor: 2.924

5.  Efficient denoising technique for CT images to enhance brain hemorrhage segmentation.

Authors:  H S Bhadauria; M L Dewal
Journal:  J Digit Imaging       Date:  2012-12       Impact factor: 4.056

6.  SR-NLM: a sinogram restoration induced non-local means image filtering for low-dose computed tomography.

Authors:  Zhaoying Bian; Jianhua Ma; Jing Huang; Hua Zhang; Shanzhou Niu; Qianjin Feng; Zhengrong Liang; Wufan Chen
Journal:  Comput Med Imaging Graph       Date:  2013-06-24       Impact factor: 4.790

7.  Low-dose X-ray computed tomography image reconstruction with a combined low-mAs and sparse-view protocol.

Authors:  Yang Gao; Zhaoying Bian; Jing Huang; Yunwan Zhang; Shanzhou Niu; Qianjin Feng; Wufan Chen; Zhengrong Liang; Jianhua Ma
Journal:  Opt Express       Date:  2014-06-16       Impact factor: 3.894

8.  Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method.

Authors:  Yinghua Tao; Guang-Hong Chen; Timothy A Hacker; Amish N Raval; Michael S Van Lysel; Michael A Speidel
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

9.  An algorithm for noise correction of dual-energy computed tomography material density images.

Authors:  Rafael Simon Maia; Christian Jacob; Amy K Hara; Alvin C Silva; William Pavlicek; Mitchell J Ross
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-05-11       Impact factor: 2.924

10.  Comparison of radiation doses using weight-based protocol and dose modulation techniques for patients undergoing biphasic abdominal computed tomography examinations.

Authors:  Roshan S Livingstone; Paul M Dinakaran; Rekha S Cherian; Anu Eapen
Journal:  J Med Phys       Date:  2009-10