Literature DB >> 24889105

A new dual threshold time-over-threshold circuit for fast timing in PET.

Alexander M Grant1, Craig S Levin.   

Abstract

Time-over-threshold (ToT) is attractive as a method of combined timing and energy encoding in positron emission tomography (PET) due to its simplicity in implementation and readout. However, conventional single threshold ToT has a nonlinear response and generally suffers from a tradeoff between timing and energy resolution. The resulting poor performance is not fit for applications requiring fast timing, such as time-of-flight (ToF) PET. In this work it is shown experimentally that by replacing single threshold ToT with a dual threshold method in a new compact circuit, excellent time resolution can be achieved (154 ps FWHM for 3 × 3 × 5 mm(3) LYSO crystals), suitable for ToF. Dual threshold ToT timing results have been compared to a similar single threshold design, demonstrating that dual threshold ToT performance is far superior to that of single threshold ToT (154 ps versus 418 ps coincidence time resolution for the dual and single threshold cases, respectively). A method of correcting for nonlinearity in dual threshold ToT energy spectra is also demonstrated.

Mesh:

Year:  2014        PMID: 24889105     DOI: 10.1088/0031-9155/59/13/3421

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

1.  Optical delay encoding for fast timing and detector signal multiplexing in PET.

Authors:  Alexander M Grant; Craig S Levin
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Electrical delay line multiplexing for pulsed mode radiation detectors.

Authors:  Ruud Vinke; Jung Yeol Yeom; Craig S Levin
Journal:  Phys Med Biol       Date:  2015-03-13       Impact factor: 3.609

3.  Highly multiplexed signal readout for a time-of-flight positron emission tomography detector based on silicon photomultipliers.

Authors:  Joshua W Cates; Matthew F Bieniosek; Craig S Levin
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-23

4.  A Time-Walk Correction Method for PET Detectors Based on Leading Edge Discriminators.

Authors:  Junwei Du; Jeffrey P Schmall; Martin S Judenhofer; Kun Di; Yongfeng Yang; Simon R Cherry
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2017-07-13

5.  Dual-Threshold Time-over-Threshold Nonlinearity Correction for PET Detectors.

Authors:  Émilie Gaudin; Christian Thibaudeau; Louis Arpin; Haithem Bouziri; Réjean Fontaine; Roger Lecomte
Journal:  Nucl Instrum Methods Phys Res A       Date:  2020-05-05       Impact factor: 1.455

6.  Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector.

Authors:  Chen-Ming Chang; Joshua W Cates; Craig S Levin
Journal:  Phys Med Biol       Date:  2016-12-17       Impact factor: 3.609

7.  A time-based single transmission-line readout with position multiplexing.

Authors:  Minseok Yi; Jae Sung Lee
Journal:  Biomed Eng Lett       Date:  2022-01-17

8.  Multiplexing Readout for Time-of-Flight (TOF) PET Detectors Using Striplines.

Authors:  Heejong Kim; Chien-Min Kao; Yuexuan Hua; Qingguo Xie; Chin-Tu Chen
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-01-13

Review 9.  Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems.

Authors:  Juan José Vaquero; Paul Kinahan
Journal:  Annu Rev Biomed Eng       Date:  2015       Impact factor: 9.590

10.  Performance evaluation of the mouse version of the LabPET II PET scanner.

Authors:  Émilie Gaudin; Christian Thibaudeau; Louis Arpin; Jean-Daniel Leroux; Maxime Toussaint; Jean-Francois Beaudoin; Jules Cadorette; Maxime Paillé; Catherine M Pepin; Konin Koua; Jonathan Bouchard; Nicolas Viscogliosi; Caroline Paulin; Réjean Fontaine; Roger Lecomte
Journal:  Phys Med Biol       Date:  2021-03-09       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.