Literature DB >> 29276798

A Time-Walk Correction Method for PET Detectors Based on Leading Edge Discriminators.

Junwei Du1, Jeffrey P Schmall2, Martin S Judenhofer1, Kun Di1, Yongfeng Yang1, Simon R Cherry1.   

Abstract

The leading edge timing pick-off technique is the simplest timing extraction method for PET detectors. Due to the inherent time-walk of the leading edge technique, corrections should be made to improve timing resolution, especially for time-of-flight PET. Time-walk correction can be done by utilizing the relationship between the threshold crossing time and the event energy on an event by event basis. In this paper, a time-walk correction method is proposed and evaluated using timing information from two identical detectors both using leading edge discriminators. This differs from other techniques that use an external dedicated reference detector, such as a fast PMT-based detector using constant fraction techniques to pick-off timing information. In our proposed method, one detector was used as reference detector to correct the time-walk of the other detector. Time-walk in the reference detector was minimized by using events within a small energy window (508.5 - 513.5 keV). To validate this method, a coincidence detector pair was assembled using two SensL MicroFB SiPMs and two 2.5 mm × 2.5 mm × 20 mm polished LYSO crystals. Coincidence timing resolutions using different time pick-off techniques were obtained at a bias voltage of 27.5 V and a fixed temperature of 20 °C. The coincidence timing resolution without time-walk correction were 389.0 ± 12.0 ps (425 -650 keV energy window) and 670.2 ± 16.2 ps (250-750 keV energy window). The timing resolution with time-walk correction improved to 367.3 ± 0.5 ps (425 - 650 keV) and 413.7 ± 0.9 ps (250 - 750 keV). For comparison, timing resolutions were 442.8 ± 12.8 ps (425 - 650 keV) and 476.0 ± 13.0 ps (250 - 750 keV) using constant fraction techniques, and 367.3 ± 0.4 ps (425 - 650 keV) and 413.4 ± 0.9 ps (250 - 750 keV) using a reference detector based on the constant fraction technique. These results show that the proposed leading edge based time-walk correction method works well. Timing resolution obtained using this method was equivalent to that obtained using a reference detector and was better than that obtained using constant fraction discriminators.

Entities:  

Keywords:  Leading edge discriminator; PET; Time of Flight; Time-walk correction; Timing resolution

Year:  2017        PMID: 29276798      PMCID: PMC5739333          DOI: 10.1109/TRPMS.2017.2726534

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  8 in total

1.  Digital timing: sampling frequency, anti-aliasing filter and signal interpolation filter dependence on timing resolution.

Authors:  Sanghee Cho; Ron Grazioso; Nan Zhang; Mehmet Aykac; Matthias Schmand
Journal:  Phys Med Biol       Date:  2011-12-07       Impact factor: 3.609

2.  Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors.

Authors:  Martin S Judenhofer; Bernd J Pichler; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

3.  A Multi-Threshold Sampling Method for TOF PET Signal Processing.

Authors:  H Kim; C M Kao; Q Xie; C T Chen; L Zhou; F Tang; H Frisch; W W Moses; W S Choong
Journal:  Nucl Instrum Methods Phys Res A       Date:  2009-04-21       Impact factor: 1.455

4.  Evaluation of Matrix9 silicon photomultiplier array for small-animal PET.

Authors:  Junwei Du; Jeffrey P Schmall; Yongfeng Yang; Kun Di; Emilie Roncali; Gregory S Mitchell; Steve Buckley; Carl Jackson; Simon R Cherry
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

5.  Performance characterization of high quantum efficiency metal package photomultiplier tubes for time-of-flight and high-resolution PET applications.

Authors:  Guen Bae Ko; Jae Sung Lee
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

6.  A new dual threshold time-over-threshold circuit for fast timing in PET.

Authors:  Alexander M Grant; Craig S Levin
Journal:  Phys Med Biol       Date:  2014-06-03       Impact factor: 3.609

7.  Fundamental limits of scintillation detector timing precision.

Authors:  Stephen E Derenzo; Woon-Seng Choong; William W Moses
Journal:  Phys Med Biol       Date:  2014-05-29       Impact factor: 3.609

8.  Optimizing timing performance of silicon photomultiplier-based scintillation detectors.

Authors:  Jung Yeol Yeom; Ruud Vinke; Craig S Levin
Journal:  Phys Med Biol       Date:  2013-01-31       Impact factor: 3.609

  8 in total
  2 in total

1.  Study of optical reflectors for a 100ps coincidence time resolution TOF-PET detector design.

Authors:  Andrea Gonzalez-Montoro; Shirin Pourashraf; Min Sun Lee; Joshua W Cates; Craig S Levin
Journal:  Biomed Phys Eng Express       Date:  2021-09-15

2.  Mini EXPLORER II: a prototype high-sensitivity PET/CT scanner for companion animal whole body and human brain scanning.

Authors:  Yang Lv; Xinyu Lv; Weiping Liu; Martin S Judenhofer; Allison Zwingenberger; Erik Wisner; Eric Berg; Sarah McKenney; Edwin Leung; Benjamin A Spencer; Simon R Cherry; Ramsey D Badawi
Journal:  Phys Med Biol       Date:  2019-03-21       Impact factor: 3.609

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.