Literature DB >> 34541433

Multiplexing Readout for Time-of-Flight (TOF) PET Detectors Using Striplines.

Heejong Kim1, Chien-Min Kao1, Yuexuan Hua2, Qingguo Xie3, Chin-Tu Chen1.   

Abstract

A recent trend in PET instrumentation is the use of silicon photomultipliers (SiPMs) for high-resolution and time-of-flight (TOF) detection. Due to its small size, a PET system can use a large number of SiPMs and hence effective and scalable multiplexing readout methods become important. Unfortunately, multiplexing readout generally degrades the fast timing properties necessary for TOF, especially at high channel reduction. Previously, we developed a stripline (SL) based readout method for PET that uses a time-based multiplexing mechanism. This method maintains fast timing by design and has been successfully used for TOF PET detectors. In this paper, we present a more systematic study in which we examine how two important design parameters of the readout - the number of inputs on an SL (n SL) and the pathlength between adjacent input positions (Δℓ) - affect its detection performance properties for PET. Our result shows that, up to n SL = 32 the readout can achieve accurate pixel discrimination and causes little degradation in the energy resolution. The TOF resolution is compromised mildly and a coincidence resolving time on the order of 300 ps FWHM can be achieved for LYSO- and SiPM-based detectors. We also discuss strategies in using the readout to further reduce the number of electronic channels that a PET system would otherwise need.

Entities:  

Keywords:  TOF PET; multiplexing readout; stripline

Year:  2021        PMID: 34541433      PMCID: PMC8445371          DOI: 10.1109/trpms.2021.3051364

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  29 in total

1.  A Design of a PET Detector Using Micro-Channel Plate Photomultipliers with Transmission-Line Readout.

Authors:  H Kim; H Frisch; C-T Chen; J-F Genat; F Tang; W W Moses; W S Choong; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2010       Impact factor: 1.455

2.  A feasibility study of a PET/MRI insert detector using strip-line and waveform sampling data acquisition.

Authors:  H Kim; C-T Chen; N Eclov; A Ronzhin; P Murat; E Ramberg; S Los; Alice M Wyrwicz; Limin Li; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2015-06-01       Impact factor: 1.455

Review 3.  PET-MRI: a review of challenges and solutions in the development of integrated multimodality imaging.

Authors:  Stefaan Vandenberghe; Paul K Marsden
Journal:  Phys Med Biol       Date:  2015-02-04       Impact factor: 3.609

4.  Hybrid charge division multiplexing method for silicon photomultiplier based PET detectors.

Authors:  Haewook Park; Guen Bae Ko; Jae Sung Lee
Journal:  Phys Med Biol       Date:  2017-04-03       Impact factor: 3.609

5.  A new dual threshold time-over-threshold circuit for fast timing in PET.

Authors:  Alexander M Grant; Craig S Levin
Journal:  Phys Med Biol       Date:  2014-06-03       Impact factor: 3.609

6.  Performance of a high-resolution depth-encoding PET detector module using linearly-graded SiPM arrays.

Authors:  Junwei Du; Xiaowei Bai; Alberto Gola; Fabio Acerbi; Alessandro Ferri; Claudio Piemonte; Yongfeng Yang; Simon R Cherry
Journal:  Phys Med Biol       Date:  2018-02-05       Impact factor: 3.609

Review 7.  Application of silicon photomultipliers to positron emission tomography.

Authors:  Emilie Roncali; Simon R Cherry
Journal:  Ann Biomed Eng       Date:  2011-02-15       Impact factor: 3.934

8.  Design, evaluation and initial imaging results of a PET insert based on strip-line readout for simultaneous PET/MRI.

Authors:  H Kim; Y Hua; H-T Chen; H-M Tsai; C-T Chen; G Karczmar; X Fan; D Xi; Q Xie; C-Y Chou; C-M Kao
Journal:  Nucl Instrum Methods Phys Res A       Date:  2020-02-05       Impact factor: 1.455

9.  Feasibility Study of a Small Animal PET Insert Based on a Single LYSO Monolithic Tube.

Authors:  Antonio J Gonzalez; Stuart S Berr; Gabriel Cañizares; Andrea Gonzalez-Montoro; Abel Orero; Carlos Correcher; Ahmadreza Rezaei; Johan Nuyts; Filomeno Sanchez; Stan Majewski; Jose M Benlloch
Journal:  Front Med (Lausanne)       Date:  2018-11-28

10.  Performance characteristics of silicon photomultiplier based 15-cm AFOV TOF PET/CT.

Authors:  Delphine Vandendriessche; Jorge Uribe; Hugo Bertin; Frank De Geeter
Journal:  EJNMMI Phys       Date:  2019-05-10
View more
  1 in total

Review 1.  Advances in Detector Instrumentation for PET.

Authors:  Andrea Gonzalez-Montoro; Muhammad Nasir Ullah; Craig S Levin
Journal:  J Nucl Med       Date:  2022-08       Impact factor: 11.082

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.