Literature DB >> 24865767

Electrode spanning with partial tripolar stimulation mode in cochlear implants.

Ching-Chih Wu1, Xin Luo.   

Abstract

The perceptual effects of electrode spanning (i.e., the use of nonadjacent return electrodes) in partial tripolar (pTP) mode were tested on a main electrode EL8 in five cochlear implant (CI) users. Current focusing was controlled by σ (the ratio of current returned within the cochlea), and current steering was controlled by α (the ratio of current returned to the basal electrode). Experiment 1 tested whether asymmetric spanning with α = 0.5 can create additional channels around standard pTP stimuli. It was found that in general, apical spanning (i.e., returning current to EL6 rather than EL7) elicited a pitch between those of standard pTP stimuli on main electrodes EL8 and EL9, while basal spanning (i.e., returning current to EL10 rather than EL9) elicited a pitch between those of standard pTP stimuli on main electrodes EL7 and EL8. The pitch increase caused by apical spanning was more salient than the pitch decrease caused by basal spanning. To replace the standard pTP channel on the main electrode EL8 when EL7 or EL9 is defective, experiment 2 tested asymmetrically spanned pTP stimuli with various α, and experiment 3 tested symmetrically spanned pTP stimuli with various σ. The results showed that pitch increased with decreasing α in asymmetric spanning, or with increasing σ in symmetric spanning. Apical spanning with α around 0.69 and basal spanning with α around 0.38 may both elicit a similar pitch as the standard pTP stimulus. With the same σ, the symmetrically spanned pTP stimulus was higher in pitch than the standard pTP stimulus. A smaller σ was thus required for symmetric spanning to match the pitch of the standard pTP stimulus. In summary, electrode spanning is an effective field-shaping technique that is useful for adding spectral channels and handling defective electrodes with CIs.

Mesh:

Year:  2014        PMID: 24865767      PMCID: PMC4389954          DOI: 10.1007/s10162-014-0464-x

Source DB:  PubMed          Journal:  J Assoc Res Otolaryngol        ISSN: 1438-7573


  27 in total

1.  Cortical responses to cochlear implant stimulation: channel interactions.

Authors:  Julie Arenberg Bierer; John C Middlebrooks
Journal:  J Assoc Res Otolaryngol       Date:  2003-10-20

Review 2.  The number of spectral channels required for speech recognition depends on the difficulty of the listening situation.

Authors:  Robert V Shannon; Qian-Jie Fu; John Galvin
Journal:  Acta Otolaryngol Suppl       Date:  2004-05

3.  Topographic spread of inferior colliculus activation in response to acoustic and intracochlear electric stimulation.

Authors:  Russell L Snyder; Julie A Bierer; John C Middlebrooks
Journal:  J Assoc Res Otolaryngol       Date:  2004-08-12

4.  Sensitivity and specificity of averaged electrode voltage measures in cochlear implant recipients.

Authors:  Michelle L Hughes; Carolyn J Brown; Paul J Abbas
Journal:  Ear Hear       Date:  2004-10       Impact factor: 3.570

5.  Effect of electrode configuration on psychophysical forward masking in cochlear implant listeners.

Authors:  Bom Jun Kwon; Chris van den Honert
Journal:  J Acoust Soc Am       Date:  2006-05       Impact factor: 1.840

6.  Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration.

Authors:  Julie Arenberg Bierer
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

7.  Spatial resolution of cochlear implants: the electrical field and excitation of auditory afferents.

Authors:  A Kral; R Hartmann; D Mortazavi; R Klinke
Journal:  Hear Res       Date:  1998-07       Impact factor: 3.208

8.  Speech recognition as a function of the number of electrodes used in the SPEAK cochlear implant speech processor.

Authors:  K E Fishman; R V Shannon; W H Slattery
Journal:  J Speech Lang Hear Res       Date:  1997-10       Impact factor: 2.297

9.  Quadrupolar stimulation for Cochlear prostheses: modeling and experimental data.

Authors:  C N Jolly; F A Spelman; B M Clopton
Journal:  IEEE Trans Biomed Eng       Date:  1996-08       Impact factor: 4.538

10.  An adaptive procedure for subjective judgments.

Authors:  W Jesteadt
Journal:  Percept Psychophys       Date:  1980-07
View more
  4 in total

1.  Excitation Patterns of Standard and Steered Partial Tripolar Stimuli in Cochlear Implants.

Authors:  Ching-Chih Wu; Xin Luo
Journal:  J Assoc Res Otolaryngol       Date:  2015-12-21

2.  Symmetric Electrode Spanning Narrows the Excitation Patterns of Partial Tripolar Stimuli in Cochlear Implants.

Authors:  Xin Luo; Ching-Chih Wu
Journal:  J Assoc Res Otolaryngol       Date:  2016-08-25

3.  Changing stimulation patterns can change the broadness of contralateral masking functions for bilateral cochlear implant users.

Authors:  Daniel H Lee; Justin M Aronoff
Journal:  Hear Res       Date:  2018-03-07       Impact factor: 3.208

4.  Reduction in spread of excitation from current focusing at multiple cochlear locations in cochlear implant users.

Authors:  Monica Padilla; David M Landsberger
Journal:  Hear Res       Date:  2016-01-08       Impact factor: 3.208

  4 in total