Threshold and channel interaction in cochlear implant users: evaluation of the tripolar electrode configuration.

Julie Arenberg Bierer1.   

Abstract

The efficacy of cochlear implants is limited by spatial and temporal interactions among channels. This study explores the spatially restricted tripolar electrode configuration and compares it to bipolar and monopolar stimulation. Measures of threshold and channel interaction were obtained from nine subjects implanted with the Clarion HiFocus-I electrode array. Stimuli were biphasic pulses delivered at 1020 pulses/s. Threshold increased from monopolar to bipolar to tripolar stimulation and was most variable across channels with the tripolar configuration. Channel interaction, quantified by the shift in threshold between single- and two-channel stimulation, occurred for all three configurations but was largest for the monopolar and simultaneous conditions. The threshold shifts with simultaneous tripolar stimulation were slightly smaller than with bipolar and were not as strongly affected by the timing of the two channel stimulation as was monopolar. The subjects' performances on clinical speech tests were correlated with channel-to-channel variability in tripolar threshold, such that greater variability was related to poorer performance. The data suggest that tripolar channels with high thresholds may reveal cochlear regions of low neuron survival or poor electrode placement.

Mesh:

Year:  2007        PMID: 17407901     DOI: 10.1121/1.2436712

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  80 in total

1.  Detection of pulse trains in the electrically stimulated cochlea: effects of cochlear health.

Authors:  Bryan E Pfingst; Deborah J Colesa; Sheena Hembrador; Stephen Y Kang; John C Middlebrooks; Yehoash Raphael; Gina L Su
Journal:  J Acoust Soc Am       Date:  2011-12       Impact factor: 1.840

2.  Monopolar intracochlear pulse trains selectively activate the inferior colliculus.

Authors:  Matthew C Schoenecker; Ben H Bonham; Olga A Stakhovskaya; Russell L Snyder; Patricia A Leake
Journal:  J Assoc Res Otolaryngol       Date:  2012-06-22

Review 3.  Probing the electrode-neuron interface with focused cochlear implant stimulation.

Authors:  Julie Arenberg Bierer
Journal:  Trends Amplif       Date:  2010-06

4.  Using temporal modulation sensitivity to select stimulation sites for processor MAPs in cochlear implant listeners.

Authors:  Soha N Garadat; Teresa A Zwolan; Bryan E Pfingst
Journal:  Audiol Neurootol       Date:  2013-07-20       Impact factor: 1.854

5.  Excitation Patterns of Standard and Steered Partial Tripolar Stimuli in Cochlear Implants.

Authors:  Ching-Chih Wu; Xin Luo
Journal:  J Assoc Res Otolaryngol       Date:  2015-12-21

6.  Effects of Age and Cochlear Implantation on Spectrally Cued Speech Categorization.

Authors:  Mishaela DiNino; Julie G Arenberg; Anne L R Duchen; Matthew B Winn
Journal:  J Speech Lang Hear Res       Date:  2020-06-18       Impact factor: 2.297

7.  Perception of speech produced by native and nonnative talkers by listeners with normal hearing and listeners with cochlear implants.

Authors:  Caili Ji; John J Galvin; Yi-ping Chang; Anting Xu; Qian-Jie Fu
Journal:  J Speech Lang Hear Res       Date:  2014-04-01       Impact factor: 2.297

8.  Spatial channel interactions in cochlear implants.

Authors:  Qing Tang; Raul Benítez; Fan-Gang Zeng
Journal:  J Neural Eng       Date:  2011-07-13       Impact factor: 5.379

9.  Psychophysical and physiological measures of electrical-field interaction in cochlear implants.

Authors:  Michelle L Hughes; Lisa J Stille
Journal:  J Acoust Soc Am       Date:  2009-01       Impact factor: 1.840

10.  Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials: Recommendations from the International HOVER Taskforce.

Authors:  Lauren N Ayton; Joseph F Rizzo; Ian L Bailey; August Colenbrander; Gislin Dagnelie; Duane R Geruschat; Philip C Hessburg; Chris D McCarthy; Matthew A Petoe; Gary S Rubin; Philip R Troyk
Journal:  Transl Vis Sci Technol       Date:  2020-07-16       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.