Effect of area x-ray beam equalization on image quality and dose in digital mammography.

Jerry Wong1, Tong Xu, Adeel Husain, Huy Le, Sabee Molloi.   

Abstract

In mammography, thick or dense breast regions persistently suffer from reduced contrast-to-noise ratio (CNR) because of degraded contrast from large scatter intensities and relatively high noise. Area x-ray beam equalization can improve image quality by increasing the x-ray exposure to under-penetrated regions without increasing the exposure to other breast regions. Optimal equalization parameters with respect to image quality and patient dose were determined through computer simulations and validated with experimental observations on a step phantom and an anthropomorphic breast phantom. Three parameters important in equalization digital mammography were considered: attenuator material (Z = 13-92), beam energy (22-34 kVp) and equalization level. A Mo/Mo digital mammography system was used for image acquisition. A prototype 16 x 16 piston driven equalization system was used for preparing patient-specific equalization masks. Simulation studies showed that a molybdenum attenuator and an equalization level of 20 were optimal for improving contrast, CNR and figure of merit (FOM = CNR2/dose). Experimental measurements using these parameters showed significant improvements in contrast, CNR and FOM. Moreover, equalized images of a breast phantom showed improved image quality. These results indicate that area beam equalization can improve image quality in digital mammography.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15446786     DOI: 10.1088/0031-9155/49/16/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.

Authors:  Xinming Liu; Chao-Jen Lai; Gary J Whitman; William R Geiser; Youtao Shen; Ying Yi; Chris C Shaw
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Preliminary report on virtual monochromatic spectral imaging with fast kVp switching dual energy head CT: comparable image quality to that of 120-kVp CT without increasing the radiation dose.

Authors:  Kouhei Kamiya; Akira Kunimatsu; Harushi Mori; Jiro Sato; Masaaki Akahane; Takana Yamakawa; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2013-02-14       Impact factor: 2.374

3.  Prospective randomised comparison of diagnostic confidence and image quality with normal-dose and low-dose CT pulmonary angiography at various body weights.

Authors:  Zsolt Szucs-Farkas; Boglarka Megyeri; Andreas Christe; Peter Vock; Johannes T Heverhagen; Sebastian T Schindera
Journal:  Eur Radiol       Date:  2014-05-28       Impact factor: 5.315

4.  Comparing image quality of single- and dual-energy computed tomography of the brain.

Authors:  Doris Dodig; Slavica Kovačić; Zrinka Matana Kaštelan; Iva Žuža; Filip Benić; Jurković Slaven; Damir Miletić; Zoran Rumboldt
Journal:  Neuroradiol J       Date:  2020-04-21

5.  An angiographic technique for coronary fractional flow reserve measurement: in vivo validation.

Authors:  Shigeho Takarada; Zhang Zhang; Sabee Molloi
Journal:  Int J Cardiovasc Imaging       Date:  2012-08-31       Impact factor: 2.357

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.