Dose reduction in general radiography for adult patients by use of a dual-side-reading photostimulable phosphor plate in a computed radiography system.

Norisato Tsuda1, Nobukazu Tanaka, Tsutomu Akasaka, Hidetake Yabuuchi, Junji Morishita.   

Abstract

Our purpose in this study was to evaluate the potential of dose reduction in general radiography for adult patients by use of a dual-side-reading (DSR) photostimulable phosphor plate in a computed radiography system. The image quality and low-contrast detectability in terms of the contrast-detail diagram of the DSR system with use of the X-ray beam quality of the RQA 5 defined by the International Electrotechnical Commission 61267 were compared with those of a conventional single-side-reading (SSR) system. The radiographic noise of the DSR system was lower compared to that of the SSR system under the same exposure conditions. Although there were no statistical differences in low-contrast detectabilities between the SSR system and the DSR system under the same exposure levels, the DSR system showed superior detectability compared to the SSR system. We conclude that the DSR system for general radiography has the potential to reduce the patient dose.

Entities:  

Mesh:

Year:  2014        PMID: 24846451     DOI: 10.1007/s12194-014-0268-z

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  13 in total

1.  New CR system with pixel size of 50 microm for digital mammography: physical imaging properties and detection of subtle microcalcifications.

Authors:  Tadamitsu Ideguchi; Yoshiharu Higashida; Yasuyuki Kawaji; Mitsuo Sasaki; Makoto Zaizen; Rei Shibayama; Yumiko Nakamura; Kimihiko Koyanagi; Hirotaka Ikeda; Masafumi Ohki; Fukai Toyofuku; Toru Muranaka
Journal:  Radiat Med       Date:  2004 Jul-Aug

2.  Comparison between a built-in "dual side" chest imaging device and a standard "single side" CR.

Authors:  Lucia Riccardi; Maria Cristina Cauzzo; Roberto Fabbris; Eugenia Tonini; Roberto Righetto
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

3.  Performance evaluation of a computed radiography imaging device using a typical "front side" and novel "dual side" readout storage phosphors.

Authors:  Kenneth A Fetterly; Beth A Schueler
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

4.  An image quality comparison of standard and dual-side read CR systems for pediatric radiology.

Authors:  P Monnin; Z Holzer; R Wolf; U Neitzel; P Vock; F Gudinchet; F R Verdun
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

5.  A comparison of the physical imaging properties of Fuji ST-V, ST-VA, and ST-VN computed radiography image plates.

Authors:  S M Kengyelics; A G Davies; A R Cowen
Journal:  Med Phys       Date:  1998-11       Impact factor: 4.071

6.  The effect of radiation dose reduction on clinical image quality in chest radiography of premature neonates using a dual-side readout technique computed radiography system.

Authors:  Anna Carlander; Jonny Hansson; Jonas Söderberg; Karin Steneryd; Magnus Båth
Journal:  Radiat Prot Dosimetry       Date:  2010-03-03       Impact factor: 0.972

7.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device.

Authors:  E Samei; M J Flynn; D A Reimann
Journal:  Med Phys       Date:  1998-01       Impact factor: 4.071

8.  Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

Authors:  Nobukazu Tanaka; Yuki Yano; Hidetake Yabuuchi; Tsutomu Akasaka; Masayuki Sasaki; Masafumi Ohki; Junji Morishita
Journal:  Radiol Phys Technol       Date:  2012-11-10

9.  Computed radiography utilizing scanning laser stimulated luminescence.

Authors:  M Sonoda; M Takano; J Miyahara; H Kato
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

10.  Comparison of different computed radiography systems: physical characterization and contrast detail analysis.

Authors:  Stefano Rivetti; Nico Lanconelli; Marco Bertolini; Andrea Nitrosi; Aldo Burani; Domenico Acchiappati
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

View more
  1 in total

1.  Benefits of using a photostimulable phosphor plate protective device.

Authors:  Graziela de Moura; Mariana Boessio Vizzotto; Priscila Fernanda da Silveira Tiecher; Nádia Assein Arús; Heraldo Luis Dias da Silveira
Journal:  Dentomaxillofac Radiol       Date:  2021-01-08       Impact factor: 3.525

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.