Literature DB >> 24975843

Diagnostic accuracy and functional parameters of myocardial perfusion scintigraphy using accelerated cardiac acquisition with IQ SPECT technique in comparison to conventional imaging.

Christian Pirich1, Peter Keinrath2, Gabriele Barth2, Gundula Rendl2, Lukas Rettenbacher2, Margarida Rodrigues2.   

Abstract

BACKGROUND: IQ SPECT consists of a new pinhole-like collimator, cardio-centric acquisition, and advanced 3D iterative SPECT reconstruction. The aim of this paper was to compare diagnostic accuracy and functional parameters obtained with IQ SPECT versus conventional SPECT in patients undergoing myocardial perfusion scintigraphy with adenosine stress and at rest.
METHODS: Eight patients with known or suspected coronary artery disease underwent [99mTc] tetrofosmin gated SPECT. Acquisition was performed on a Symbia T6 equipped with IQ SPECT and on a conventional gamma camera system. Gated SPECT data were used to calculate functional parameters. Scores analysis was performed on a 17-segment model. Coronary angiography and clinical follow-up were considered as diagnostic reference standard.
RESULTS: Mean acquisition time was 4 minutes with IQ SPECT and 21 minutes with conventional SPECT. Agreement degree on the diagnostic accuracy between both systems was 0.97 for stress studies, 0.91 for rest studies and 0.96 for both studies. Perfusion abnormalities scores obtained by using IQ SPECT and conventional SPECT were not significant different: SSS, 9.7±8.8 and 10.1±6.4; SRS, 7.1±6.1 and 7.5±7.3; SDS, 4.0±6.1 and 3.9±4.3, respectively. However, a significant difference was found in functional parameters derived from IQ SPECT and conventional SPECT both after stress and at rest. Mean LVEF was 8% lower using IQ SPECT. Differences in LVEF were found in patients with normal LVEF and patients with reduced LVEF.
CONCLUSIONS: Functional parameters using accelerated cardiac acquisition with IQ SPECT are significantly different to those obtained with conventional SPECT, while agreement for clinical interpretation of myocardial perfusion scintigraphy with both techniques is high.

Entities:  

Mesh:

Year:  2014        PMID: 24975843     DOI: 10.23736/S1824-4785.16.02703-5

Source DB:  PubMed          Journal:  Q J Nucl Med Mol Imaging        ISSN: 1824-4785            Impact factor:   2.346


  6 in total

1.  How to use cardiac IQ•SPECT routinely? An overview of tips and tricks from practical experience to the literature.

Authors:  Eric Gremillet; Denis Agostini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-04       Impact factor: 9.236

2.  Assessment of left ventricular ejection fraction with cardiofocal collimators: Comparison between IQ-SPECT, planar equilibrium radionuclide angiography, and cardiac magnetic resonance.

Authors:  Matthieu Pelletier-Galarneau; Vincent Finnerty; Stephanie Tan; Sebastien Authier; Jean Gregoire; Francois Harel
Journal:  J Nucl Cardiol       Date:  2018-03-08       Impact factor: 5.952

3.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

4.  Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT.

Authors:  Federico Caobelli; James T Thackeray; Alberto Soffientini; Frank M Bengel; Claudio Pizzocaro; Ugo Paolo Guerra
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-08-01       Impact factor: 9.236

Review 5.  Diagnostic value of cadmium-zinc-telluride myocardial perfusion imaging versus coronary angiography in coronary artery disease: A PRISMA-compliant meta-analysis.

Authors:  Yi-Qing Zhang; Yu-Feng Jiang; Lu Hong; Min Chen; Nan-Nan Zhang; Hua-Jia Yang; Ya-Feng Zhou
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

6.  EANM procedural guidelines for myocardial perfusion scintigraphy using cardiac-centered gamma cameras.

Authors:  Fabien Hyafil; Alessia Gimelli; Riemer H J A Slart; Panagiotis Georgoulias; Christoph Rischpler; Mark Lubberink; Roberto Sciagra; Jan Bucerius; Denis Agostini; Hein J Verberne
Journal:  Eur J Hybrid Imaging       Date:  2019-07-02
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.