Literature DB >> 19610291

Quantitative evaluation of simultaneous reconstruction with model-based crosstalk compensation for 99mTc/123I dual-isotope simultaneous acquisition brain SPECT.

Yong Du1, Eric C Frey.   

Abstract

A model-based method has been previously developed to estimate and compensate for the crosstalk and downscatter contamination in simultaneous 123I/99mTc dual-isotope SPECT imaging. In this method, photon scatter in the object is modeled using the effective source scatter estimate technique. Photon interactions with the collimator-detector are estimated using precalculated Monte Carlo simulated point response functions. Two different approaches, simultaneous and alternating model-based compensations, have been proposed for iterative reconstruction-based crosstalk and downscatter contamination compensation. In this work, both model-based approaches were evaluated in the context of quantitative accuracy when imaging the dopaminergic system using both Monte Carlo simulated and experimentally acquired data. Results indicate that mddel-based estimates of the crosstalk and downscatter contamination in both energy windows were in good agreement with the truth for the simulated data. The effects of the contamination reduced image contrast and overestimated absolute activity in all structures by up to 66%. Compensation using both model-based approaches improved image contrast. Errors in absolute activity quantitation were also reduced to less than +/-5% for most brain structures. The accuracy of striatal specific binding potentials, calculated as the ratio of activity in various striatal structures to the background, was also greatly improved after model-based compensation. In conclusion, model-based compensation of simultaneously acquired images of 99mTc and 123I labeled brain imaging agents provided image quality and quantitative accuracy that were comparable to the image without crosstalk. Both proposed compensation approaches can potentially be applied clinically, but when reconstruction time is a limiting factor, the alternating model-based compensation may be preferable.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19610291      PMCID: PMC2736700          DOI: 10.1118/1.3120411

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  Dual-isotope brain SPECT imaging with technetium-99m and iodine-123: validation by phantom studies.

Authors:  M D Devous; J L Lowe; J K Payne
Journal:  J Nucl Med       Date:  1992-11       Impact factor: 10.057

2.  Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function.

Authors:  X Song; W P Segars; Y Du; B M W Tsui; E C Frey
Journal:  Phys Med Biol       Date:  2005-04-06       Impact factor: 3.609

3.  Partial volume effect compensation for quantitative brain SPECT imaging.

Authors:  Yong Du; Benjamin M W Tsui; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

4.  Correction for partial volume effects in PET: principle and validation.

Authors:  O G Rousset; Y Ma; A C Evans
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

5.  Computerized three-dimensional segmented human anatomy.

Authors:  I G Zubal; C R Harrell; E O Smith; Z Rattner; G Gindi; P B Hoffer
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

6.  Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  Phys Med Biol       Date:  1999-07       Impact factor: 3.609

7.  Single photon emission tomography imaging in parkinsonian disorders: a review.

Authors:  P D Acton; P D Mozley
Journal:  Behav Neurol       Date:  2000       Impact factor: 3.342

8.  [99mTc]TRODAT-1: a novel technetium-99m complex as a dopamine transporter imaging agent.

Authors:  M P Kung; D A Stevenson; K Plössl; S K Meegalla; A Beckwith; W D Essman; M Mu; I Lucki; H F Kung
Journal:  Eur J Nucl Med       Date:  1997-04

9.  Multiple system atrophy and progressive supranuclear palsy. Diminished striatal D2 dopamine receptor activity demonstrated by 123I-IBZM single photon emission computed tomography.

Authors:  E van Royen; N F Verhoeff; J D Speelman; E C Wolters; M A Kuiper; A G Janssen
Journal:  Arch Neurol       Date:  1993-05

10.  Dual SPECT of dopamine system using [99mTc]TRODAT-1 and [123I]IBZM in normal and 6-OHDA-lesioned formosan rock monkeys.

Authors:  Kuo-Hsing Ma; Wen-Sheng Huang; Chien-Hsing Chen; Shin-Zong Lin; Shiaw-Pyng Wey; Gann Ting; Shwun-De Wang; Hwan-Wun Liu; Jiang-Chuan Liu
Journal:  Nucl Med Biol       Date:  2002-07       Impact factor: 2.408

View more
  9 in total

1.  Comparison of simultaneous and sequential SPECT imaging for discrimination tasks in assessment of cardiac defects.

Authors:  C M Trott; J Ouyang; G El Fakhri
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

2.  Simultaneous Evaluation of Safety, Acceptability, Pericoital Kinetics, and Ex Vivo Pharmacodynamics Comparing Four Rectal Microbicide Vehicle Candidates.

Authors:  Francisco Leyva; Edward J Fuchs; Rahul Bakshi; Alex Carballo-Dieguez; Ana Ventuneac; Chen Yue; Brian Caffo; Yong Du; Michael Torbenson; Liye Li; Gerald Mullin; Linda Lee; Lisa Rohan; Peter A Anton; Craig W Hendrix
Journal:  AIDS Res Hum Retroviruses       Date:  2015-07-08       Impact factor: 2.205

3.  A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

Authors:  Abhinav K Jha; Brian Caffo; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-03-16       Impact factor: 3.609

4.  Evaluation of quantitative accuracy among different scatter corrections for quantitative bone SPECT/CT imaging.

Authors:  Kenta Miwa; Reo Nemoto; Hirotsugu Masuko; Tensho Yamao; Rinya Kobayashi; Noriaki Miyaji; Kosuke Inoue; Hiroya Onodera
Journal:  PLoS One       Date:  2022-06-06       Impact factor: 3.752

5.  Simultaneous Tc-99m/I-123 dual-radionuclide myocardial perfusion/innervation imaging using Siemens IQ-SPECT with SMARTZOOM collimator.

Authors:  Yong Du; Manojeet Bhattacharya; Eric C Frey
Journal:  Phys Med Biol       Date:  2014-05-13       Impact factor: 3.609

6.  A Phase 1 Randomized, Blinded Comparison of the Pharmacokinetics and Colonic Distribution of Three Candidate Rectal Microbicide Formulations of Tenofovir 1% Gel with Simulated Unprotected Sex (CHARM-02).

Authors:  Hiwot Hiruy; Edward J Fuchs; Mark A Marzinke; Rahul P Bakshi; Jennifer C Breakey; Wutyi S Aung; Madhuri Manohar; Chen Yue; Brian S Caffo; Yong Du; Kaleab Z Abebe; Hans M L Spiegel; Lisa C Rohan; Ian McGowan; Craig W Hendrix
Journal:  AIDS Res Hum Retroviruses       Date:  2015-08-24       Impact factor: 2.205

7.  Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction.

Authors:  Wataru Takeuchi; Atsuro Suzuki; Tohru Shiga; Naoki Kubo; Yuichi Morimoto; Yuichiro Ueno; Keiji Kobashi; Kikuo Umegaki; Nagara Tamaki
Journal:  EJNMMI Phys       Date:  2016-06-29

Review 8.  Nuclear molecular imaging with nanoparticles: radiochemistry, applications and translation.

Authors:  D S Abou; J E Pickett; D L J Thorek
Journal:  Br J Radiol       Date:  2015-07-02       Impact factor: 3.039

9.  Crosstalk Reduction Using a Dual Energy Window Scatter Correction in Compton Imaging.

Authors:  Makoto Sakai; Raj Kumar Parajuli; Yoshiki Kubota; Nobuteru Kubo; Mitsutaka Yamaguchi; Yuto Nagao; Naoki Kawachi; Mikiko Kikuchi; Kazuo Arakawa; Mutsumi Tashiro
Journal:  Sensors (Basel)       Date:  2020-04-26       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.