MRI-based treatment planning with pseudo CT generated through atlas registration.

Jinsoo Uh1, Thomas E Merchant1, Yimei Li2, Xingyu Li2, Chiaho Hua1.   

Abstract

PURPOSE: To evaluate the feasibility and accuracy of magnetic resonance imaging (MRI)-based treatment planning using pseudo CTs generated through atlas registration.
METHODS: A pseudo CT, providing electron density information for dose calculation, was generated by deforming atlas CT images previously acquired on other patients. The authors tested 4 schemes of synthesizing a pseudo CT from single or multiple deformed atlas images: use of a single arbitrarily selected atlas, arithmetic mean process using 6 atlases, and pattern recognition with Gaussian process (PRGP) using 6 or 12 atlases. The required deformation for atlas CT images was derived from a nonlinear registration of conjugated atlas MR images to that of the patient of interest. The contrasts of atlas MR images were adjusted by histogram matching to reduce the effect of different sets of acquisition parameters. For comparison, the authors also tested a simple scheme assigning the Hounsfield unit of water to the entire patient volume. All pseudo CT generating schemes were applied to 14 patients with common pediatric brain tumors. The image similarity of real patient-specific CT and pseudo CTs constructed by different schemes was compared. Differences in computation times were also calculated. The real CT in the treatment planning system was replaced with the pseudo CT, and the dose distribution was recalculated to determine the difference.
RESULTS: The atlas approach generally performed better than assigning a bulk CT number to the entire patient volume. Comparing atlas-based schemes, those using multiple atlases outperformed the single atlas scheme. For multiple atlas schemes, the pseudo CTs were similar to the real CTs (correlation coefficient, 0.787-0.819). The calculated dose distribution was in close agreement with the original dose. Nearly the entire patient volume (98.3%-98.7%) satisfied the criteria of chi-evaluation (<2% maximum dose and 2 mm range). The dose to 95% of the volume and the percentage of volume receiving at least 95% of the prescription dose in the planning target volume differed from the original values by less than 2% of the prescription dose (root-mean-square, RMS < 1%). The PRGP scheme did not perform better than the arithmetic mean process with the same number of atlases. Increasing the number of atlases from 6 to 12 often resulted in improvements, but statistical significance was not always found.
CONCLUSIONS: MRI-based treatment planning with pseudo CTs generated through atlas registration is feasible for pediatric brain tumor patients. The doses calculated from pseudo CTs agreed well with those from real CTs, showing dosimetric accuracy within 2% for the PTV when multiple atlases were used. The arithmetic mean process may be a reasonable choice over PRGP for the synthesis scheme considering performance and computational costs.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24784377      PMCID: PMC5148041          DOI: 10.1118/1.4873315

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  T1/T2*-weighted MRI provides clinically relevant pseudo-CT density data for the pelvic bones in MRI-only based radiotherapy treatment planning.

Authors:  Mika Kapanen; Mikko Tenhunen
Journal:  Acta Oncol       Date:  2012-06-19       Impact factor: 4.089

2.  Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapy.

Authors:  S P M Crijns; B W Raaymakers; J J W Lagendijk
Journal:  Phys Med Biol       Date:  2010-12-09       Impact factor: 3.609

3.  Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept.

Authors:  B W Raaymakers; J J W Lagendijk; J Overweg; J G M Kok; A J E Raaijmakers; E M Kerkhof; R W van der Put; I Meijsing; S P M Crijns; F Benedosso; M van Vulpen; C H W de Graaff; J Allen; K J Brown
Journal:  Phys Med Biol       Date:  2009-05-19       Impact factor: 3.609

4.  A two-step scheme for distortion rectification of magnetic resonance images.

Authors:  Lesley N Baldwin; Keith Wachowicz; B Gino Fallone
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

5.  First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system.

Authors:  B G Fallone; B Murray; S Rathee; T Stanescu; S Steciw; S Vidakovic; E Blosser; D Tymofichuk
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

6.  Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT.

Authors:  T Stanescu; K Wachowicz; D A Jaffray
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration.

Authors:  Eduard Schreibmann; Jonathon A Nye; David M Schuster; Diego R Martin; John Votaw; Tim Fox
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

8.  MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences.

Authors:  Vincent Keereman; Yves Fierens; Tom Broux; Yves De Deene; Max Lonneux; Stefaan Vandenberghe
Journal:  J Nucl Med       Date:  2010-05       Impact factor: 10.057

9.  Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

Authors:  Ciprian Catana; Andre van der Kouwe; Thomas Benner; Christian J Michel; Michael Hamm; Matthias Fenchel; Bruce Fischl; Bruce Rosen; Matthias Schmand; A Gregory Sorensen
Journal:  J Nucl Med       Date:  2010-09       Impact factor: 10.057

10.  Patient-induced susceptibility effect on geometric distortion of clinical brain MRI for radiation treatment planning on a 3T scanner.

Authors:  H Wang; J Balter; Y Cao
Journal:  Phys Med Biol       Date:  2013-01-10       Impact factor: 3.609

View more
  52 in total

Review 1.  Individualized radiotherapy by combining high-end irradiation and magnetic resonance imaging.

Authors:  Stephanie E Combs; Fridtjof Nüsslin; Jan J Wilkens
Journal:  Strahlenther Onkol       Date:  2016-02-06       Impact factor: 3.621

2.  MR image-based synthetic CT for IMRT prostate treatment planning and CBCT image-guided localization.

Authors:  Shupeng Chen; Hong Quan; An Qin; Seonghwan Yee; Di Yan
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

3.  New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

Authors:  Xun Jia; Zhen Tian; Yan Xi; Steve B Jiang; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

4.  Magnetic resonance imaging-based pseudo computed tomography using anatomic signature and joint dictionary learning.

Authors:  Yang Lei; Hui-Kuo Shu; Sibo Tian; Jiwoong Jason Jeong; Tian Liu; Hyunsuk Shim; Hui Mao; Tonghe Wang; Ashesh B Jani; Walter J Curran; Xiaofeng Yang
Journal:  J Med Imaging (Bellingham)       Date:  2018-08-24

5.  Multiatlas approach with local registration goodness weighting for MRI-based electron density mapping of head and neck anatomy.

Authors:  Reza Farjam; Neelam Tyagi; Harini Veeraraghavan; Aditya Apte; Kristen Zakian; Margie A Hunt; Joseph O Deasy
Journal:  Med Phys       Date:  2017-06-01       Impact factor: 4.071

6.  MRI-based treatment planning for brain stereotactic radiosurgery: Dosimetric validation of a learning-based pseudo-CT generation method.

Authors:  Tonghe Wang; Nivedh Manohar; Yang Lei; Anees Dhabaan; Hui-Kuo Shu; Tian Liu; Walter J Curran; Xiaofeng Yang
Journal:  Med Dosim       Date:  2018-08-14       Impact factor: 1.482

Review 7.  Emerging role of MRI in radiation therapy.

Authors:  Hersh Chandarana; Hesheng Wang; R H N Tijssen; Indra J Das
Journal:  J Magn Reson Imaging       Date:  2018-09-08       Impact factor: 4.813

8.  Dose evaluation of MRI-based synthetic CT generated using a machine learning method for prostate cancer radiotherapy.

Authors:  Ghazal Shafai-Erfani; Tonghe Wang; Yang Lei; Sibo Tian; Pretesh Patel; Ashesh B Jani; Walter J Curran; Tian Liu; Xiaofeng Yang
Journal:  Med Dosim       Date:  2019-02-01       Impact factor: 1.482

Review 9.  MRI-only treatment planning: benefits and challenges.

Authors:  Amir M Owrangi; Peter B Greer; Carri K Glide-Hurst
Journal:  Phys Med Biol       Date:  2018-02-26       Impact factor: 3.609

10.  Image Guided Radiation Therapy Using Synthetic Computed Tomography Images in Brain Cancer.

Authors:  Ryan G Price; Joshua P Kim; Weili Zheng; Indrin J Chetty; Carri Glide-Hurst
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-03-10       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.