Literature DB >> 19451689

Integrating a 1.5 T MRI scanner with a 6 MV accelerator: proof of concept.

B W Raaymakers1, J J W Lagendijk, J Overweg, J G M Kok, A J E Raaijmakers, E M Kerkhof, R W van der Put, I Meijsing, S P M Crijns, F Benedosso, M van Vulpen, C H W de Graaff, J Allen, K J Brown.   

Abstract

At the UMC Utrecht, The Netherlands, we have constructed a prototype MRI accelerator. The prototype is a modified 6 MV Elekta (Crawley, UK) accelerator next to a modified 1.5 T Philips Achieva (Best, The Netherlands) MRI system. From the initial design onwards, modifications to both systems were aimed to yield simultaneous and unhampered operation of the MRI and the accelerator. Indeed, the simultaneous operation is shown by performing diagnostic quality 1.5 T MRI with the radiation beam on. No degradation of the performance of either system was found. The integrated 1.5 T MRI system and radiotherapy accelerator allow simultaneous irradiation and MR imaging. The full diagnostic imaging capacities of the MRI can be used; dedicated sequences for MRI-guided radiotherapy treatments will be developed. This proof of concept opens the door towards a clinical prototype to start testing MRI-guided radiation therapy (MRIgRT) in the clinic.

Mesh:

Year:  2009        PMID: 19451689     DOI: 10.1088/0031-9155/54/12/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  128 in total

Review 1.  Functional MRI for radiotherapy dose painting.

Authors:  Uulke A van der Heide; Antonetta C Houweling; Greetje Groenendaal; Regina G H Beets-Tan; Philippe Lambin
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

2.  Assessing the image quality of pelvic MR images acquired with a flat couch for radiotherapy treatment planning.

Authors:  M McJury; A O'Neill; M Lawson; C McGrath; A Grey; W Page; J M O'Sullivan
Journal:  Br J Radiol       Date:  2011-08       Impact factor: 3.039

3.  A Novel method to generate on-board 4D MRI using prior 4D MRI and on-board kV projections from a conventional LINAC for target localization in liver SBRT.

Authors:  Wendy Harris; Chunhao Wang; Fang-Fang Yin; Jing Cai; Lei Ren
Journal:  Med Phys       Date:  2018-06-13       Impact factor: 4.071

4.  A study of the effect of in-line and perpendicular magnetic fields on beam characteristics of electron guns in medical linear accelerators.

Authors:  Dragoş E Constantin; Rebecca Fahrig; Paul J Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

5.  Spatiotemporal fractionation schemes for liver stereotactic body radiotherapy.

Authors:  Jan Unkelbach; Dávid Papp; Melissa R Gaddy; Nicolaus Andratschke; Theodore Hong; Matthias Guckenberger
Journal:  Radiother Oncol       Date:  2017-09-23       Impact factor: 6.280

Review 6.  A review of recent advances in optical fibre sensors for in vivo dosimetry during radiotherapy.

Authors:  S O'Keeffe; D McCarthy; P Woulfe; M W D Grattan; A R Hounsell; D Sporea; L Mihai; I Vata; G Leen; E Lewis
Journal:  Br J Radiol       Date:  2015-03-11       Impact factor: 3.039

Review 7.  Imaging strategies in the management of gastric cancer: current role and future potential of MRI.

Authors:  Alicia S Borggreve; Lucas Goense; Hylke J F Brenkman; Stella Mook; Gert J Meijer; Frank J Wessels; Marcel Verheij; Edwin P M Jansen; Richard van Hillegersberg; Peter S N van Rossum; Jelle P Ruurda
Journal:  Br J Radiol       Date:  2019-03-05       Impact factor: 3.039

8.  Feasibility of spinal stereotactic body radiotherapy in Elekta Unity® MR-Linac.

Authors:  Eun Young Han; Manik Aima; Neil Hughes; Tina M Briere; Debra N Yeboa; Pam Castillo; Jihong Wang; Jinzhong Yang; Sastry Vedam
Journal:  J Radiosurg SBRT       Date:  2020

9.  New concept on an integrated interior magnetic resonance imaging and medical linear accelerator system for radiation therapy.

Authors:  Xun Jia; Zhen Tian; Yan Xi; Steve B Jiang; Ge Wang
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-02

10.  Monte Carlo study of the chamber-phantom air gap effect in a magnetic field.

Authors:  Daniel J O'Brien; Gabriel O Sawakuchi
Journal:  Med Phys       Date:  2017-05-26       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.