Literature DB >> 24772209

Errors in Quantitative Image Analysis due to Platform-Dependent Image Scaling.

Thomas L Chenevert1, Dariya I Malyarenko1, David Newitt2, Xin Li3, Mohan Jayatilake3, Alina Tudorica3, Andriy Fedorov4, Ron Kikinis4, Tiffany Ting Liu5, Mark Muzi6, Matthew J Oborski7, Charles M Laymon7, Xia Li8, Yankeelov Thomas8, Kalpathy-Cramer Jayashree9, James M Mountz7, Paul E Kinahan6, Daniel L Rubin5, Fiona Fennessy4, Wei Huang3, Nola Hylton2, Brian D Ross1.   

Abstract

PURPOSE: To evaluate the ability of various software (SW) tools used for quantitative image analysis to properly account for source-specific image scaling employed by magnetic resonance imaging manufacturers.
METHODS: A series of gadoteridol-doped distilled water solutions (0%, 0.5%, 1%, and 2% volume concentrations) was prepared for manual substitution into one (of three) phantom compartments to create "variable signal," whereas the other two compartments (containing mineral oil and 0.25% gadoteriol) were held unchanged. Pseudodynamic images were acquired over multiple series using four scanners such that the histogram of pixel intensities varied enough to provoke variable image scaling from series to series. Additional diffusion-weighted images were acquired of an ice-water phantom to generate scanner-specific apparent diffusion coefficient (ADC) maps. The resulting pseudodynamic images and ADC maps were analyzed by eight centers of the Quantitative Imaging Network using 16 different SW tools to measure compartment-specific region-of-interest intensity.
RESULTS: Images generated by one of the scanners appeared to have additional intensity scaling that was not accounted for by the majority of tested quantitative image analysis SW tools. Incorrect image scaling leads to intensity measurement bias near 100%, compared to nonscaled images.
CONCLUSION: Corrective actions for image scaling are suggested for manufacturers and quantitative imaging community.

Entities:  

Year:  2014        PMID: 24772209      PMCID: PMC3998685          DOI: 10.1593/tlo.13811

Source DB:  PubMed          Journal:  Transl Oncol        ISSN: 1936-5233            Impact factor:   4.243


  17 in total

1.  Introduction to the DICOM standard.

Authors:  Peter Mildenberger; Marco Eichelberg; Eric Martin
Journal:  Eur Radiol       Date:  2001-09-15       Impact factor: 5.315

Review 2.  Dynamic contrast-enhanced MRI in clinical trials of antivascular therapies.

Authors:  James P B O'Connor; Alan Jackson; Geoff J M Parker; Caleb Roberts; Gordon C Jayson
Journal:  Nat Rev Clin Oncol       Date:  2012-02-14       Impact factor: 66.675

3.  Intensity non-uniformity correction in MRI: existing methods and their validation.

Authors:  Boubakeur Belaroussi; Julien Milles; Sabin Carme; Yue Min Zhu; Hugues Benoit-Cattin
Journal:  Med Image Anal       Date:  2005-11-22       Impact factor: 8.545

4.  T1 measurements incorporating flip angle calibration and correction in vivo.

Authors:  Jinghua Wang; Maolin Qiu; Hyeonjin Kim; R Todd Constable
Journal:  J Magn Reson       Date:  2006-07-27       Impact factor: 2.229

5.  Intensity non-uniformity correction using N3 on 3-T scanners with multichannel phased array coils.

Authors:  Richard G Boyes; Jeff L Gunter; Chris Frost; Andrew L Janke; Thomas Yeatman; Derek L G Hill; Matt A Bernstein; Paul M Thompson; Michael W Weiner; Norbert Schuff; Gene E Alexander; Ronald J Killiany; Charles DeCarli; Clifford R Jack; Nick C Fox
Journal:  Neuroimage       Date:  2007-10-30       Impact factor: 6.556

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Diffusion coefficient measurement using a temperature-controlled fluid for quality control in multicenter studies.

Authors:  Thomas L Chenevert; Craig J Galbán; Marko K Ivancevic; Susan E Rohrer; Frank J Londy; Thomas C Kwee; Charles R Meyer; Timothy D Johnson; Alnawaz Rehemtulla; Brian D Ross
Journal:  J Magn Reson Imaging       Date:  2011-10       Impact factor: 4.813

Review 8.  Promise and pitfalls of quantitative imaging in oncology clinical trials.

Authors:  Brenda F Kurland; Elizabeth R Gerstner; James M Mountz; Lawrence H Schwartz; Christopher W Ryan; Michael M Graham; John M Buatti; Fiona M Fennessy; Edward A Eikman; Virendra Kumar; Kenneth M Forster; Richard L Wahl; Frank S Lieberman
Journal:  Magn Reson Imaging       Date:  2012-08-13       Impact factor: 2.546

9.  Diffusion imaging for therapy response assessment of brain tumor.

Authors:  Thomas L Chenevert; Brian D Ross
Journal:  Neuroimaging Clin N Am       Date:  2009-11       Impact factor: 2.264

10.  DICOM structured reporting and cancer clinical trials results.

Authors:  David A Clunie
Journal:  Cancer Inform       Date:  2007-05-12
View more
  21 in total

Review 1.  Mechanism-Based Modeling of Tumor Growth and Treatment Response Constrained by Multiparametric Imaging Data.

Authors:  David A Hormuth; Angela M Jarrett; Ernesto A B F Lima; Matthew T McKenna; David T Fuentes; Thomas E Yankeelov
Journal:  JCO Clin Cancer Inform       Date:  2019-02

2.  Impact of uncertainty in longitudinal T1 measurements on quantification of dynamic contrast-enhanced MRI.

Authors:  Madhava P Aryal; Thomas L Chenevert; Yue Cao
Journal:  NMR Biomed       Date:  2016-01-21       Impact factor: 4.044

3.  Repeatability and reproducibility of ADC measurements: a prospective multicenter whole-body-MRI study.

Authors:  Nicolas F Michoux; Jakub W Ceranka; Jef Vandemeulebroucke; Frank Peeters; Pierre Lu; Julie Absil; Perrine Triqueneaux; Yan Liu; Laurence Collette; Inneke Willekens; Carola Brussaard; Olivier Debeir; Stephan Hahn; Hubert Raeymaekers; Johan de Mey; Thierry Metens; Frédéric E Lecouvet
Journal:  Eur Radiol       Date:  2021-01-06       Impact factor: 5.315

4.  Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

Authors:  Octavia Bane; Stefanie J Hectors; Mathilde Wagner; Lori L Arlinghaus; Madhava P Aryal; Yue Cao; Thomas L Chenevert; Fiona Fennessy; Wei Huang; Nola M Hylton; Jayashree Kalpathy-Cramer; Kathryn E Keenan; Dariya I Malyarenko; Robert V Mulkern; David C Newitt; Stephen E Russek; Karl F Stupic; Alina Tudorica; Lisa J Wilmes; Thomas E Yankeelov; Yi-Fei Yen; Michael A Boss; Bachir Taouli
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

5.  Special Section Guest Editorial: Quantitative Imaging and the Pioneering Efforts of Laurence P. Clarke.

Authors:  Robert J Nordstrom
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-13

6.  Phantom validation of quantitative susceptibility and dynamic contrast-enhanced permeability MR sequences across instruments and sites.

Authors:  Nicholas Hobson; Sean P Polster; Ying Cao; Kelly Flemming; Yunhong Shu; John Huston; Chandra Y Gerrard; Reed Selwyn; Marc Mabray; Atif Zafar; Romuald Girard; Julián Carrión-Penagos; Yu Fen Chen; Todd Parrish; Xiaohong Joe Zhou; James I Koenig; Robert Shenkar; Agnieszka Stadnik; Janne Koskimäki; Alexey Dimov; Dallas Turley; Timothy Carroll; Issam A Awad
Journal:  J Magn Reson Imaging       Date:  2019-09-12       Impact factor: 4.813

7.  Volume of high-risk intratumoral subregions at multi-parametric MR imaging predicts overall survival and complements molecular analysis of glioblastoma.

Authors:  Yi Cui; Shangjie Ren; Khin Khin Tha; Jia Wu; Hiroki Shirato; Ruijiang Li
Journal:  Eur Radiol       Date:  2017-02-06       Impact factor: 5.315

8.  Mesenteric lymph nodes in MR enterography: are they reliable followers of bowel in active Crohn's disease?

Authors:  Amir Reza Radmard; Rana Eftekhar Vaghefi; Seyed Ali Montazeri; Sara Naybandi Atashi; Amir Pejman Hashemi Taheri; Sepehr Haghighi; Aneseh Salehnia; Mehrdad Dadgostar; Reza Malekzadeh
Journal:  Eur Radiol       Date:  2018-04-25       Impact factor: 5.315

Review 9.  Diffusion-weighted magnetic resonance imaging in cancer: Reported apparent diffusion coefficients, in-vitro and in-vivo reproducibility.

Authors:  Maysam M Jafar; Arman Parsai; Marc E Miquel
Journal:  World J Radiol       Date:  2016-01-28

10.  Multi-site, multi-platform comparison of MRI T1 measurement using the system phantom.

Authors:  Kathryn E Keenan; Zydrunas Gimbutas; Andrew Dienstfrey; Karl F Stupic; Michael A Boss; Stephen E Russek; Thomas L Chenevert; P V Prasad; Junyu Guo; Wilburn E Reddick; Kim M Cecil; Amita Shukla-Dave; David Aramburu Nunez; Amaresh Shridhar Konar; Michael Z Liu; Sachin R Jambawalikar; Lawrence H Schwartz; Jie Zheng; Peng Hu; Edward F Jackson
Journal:  PLoS One       Date:  2021-06-30       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.