Literature DB >> 16875852

T1 measurements incorporating flip angle calibration and correction in vivo.

Jinghua Wang1, Maolin Qiu, Hyeonjin Kim, R Todd Constable.   

Abstract

In this work, we propose a variable FA method that combines in vivo flip angle (FA) calibration and correction with a short TR variable FA approach for a fast and accurate T(1) mapping. The precision T(1)s measured across a uniform milk phantom is estimated to be 2.65% using the conventional (slow) inversion recovery (IR) method and 28.5% for the variable FA method without FA correction, and 2.2% when FA correction is included. These results demonstrate that the sensitivity of the variable FA method to RF nonuniformities can be dramatically reduced when these nonuniformities are directly measured and corrected. The acquisition time for this approach decreases to 10 min from 85 min for the conventional IR method. In addition, we report that the averaged T(1)s measured from five normal subjects are 900 +/- 3 ms, 1337 +/- 8 ms and 2180 +/- 25 ms in white matter (WM), gray matter (GM) and cerebral spinal fluid (CSF) using the variable flip angle method with FA correction at 3 T, respectively. These results are consistent with previously reported values obtained with much longer acquisition times. The method reduces the total scan time for whole brain T(1) mapping, including FA measurement and calibration, to approximately 6 min. The novelty of this method lies in the in vivo calibration and the correction of the FAs, thereby allowing a rapid and accurate T(1) mapping at high field for many applications.

Entities:  

Mesh:

Year:  2006        PMID: 16875852     DOI: 10.1016/j.jmr.2006.07.005

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  33 in total

1.  Physiological noise effects on the flip angle selection in BOLD fMRI.

Authors:  J Gonzalez-Castillo; V Roopchansingh; P A Bandettini; J Bodurka
Journal:  Neuroimage       Date:  2010-11-10       Impact factor: 6.556

2.  Impact of uncertainty in longitudinal T1 measurements on quantification of dynamic contrast-enhanced MRI.

Authors:  Madhava P Aryal; Thomas L Chenevert; Yue Cao
Journal:  NMR Biomed       Date:  2016-01-21       Impact factor: 4.044

3.  Rapid high-resolution three-dimensional mapping of T1 and age-dependent variations in the non-human primate brain using magnetization-prepared rapid gradient-echo (MPRAGE) sequence.

Authors:  Junjie V Liu; Nicholas A Bock; Afonso C Silva
Journal:  Neuroimage       Date:  2011-03-03       Impact factor: 6.556

4.  A new algebraic method for quantitative proton density mapping using multi-channel coil data.

Authors:  Dietmar Cordes; Zhengshi Yang; Xiaowei Zhuang; Karthik Sreenivasan; Virendra Mishra; Le H Hua
Journal:  Med Image Anal       Date:  2017-06-23       Impact factor: 8.545

5.  Automatic brain segmentation using fractional signal modeling of a multiple flip angle, spoiled gradient-recalled echo acquisition.

Authors:  André Ahlgren; Ronnie Wirestam; Freddy Ståhlberg; Linda Knutsson
Journal:  MAGMA       Date:  2014-03-18       Impact factor: 2.310

6.  Errors in Quantitative Image Analysis due to Platform-Dependent Image Scaling.

Authors:  Thomas L Chenevert; Dariya I Malyarenko; David Newitt; Xin Li; Mohan Jayatilake; Alina Tudorica; Andriy Fedorov; Ron Kikinis; Tiffany Ting Liu; Mark Muzi; Matthew J Oborski; Charles M Laymon; Xia Li; Yankeelov Thomas; Kalpathy-Cramer Jayashree; James M Mountz; Paul E Kinahan; Daniel L Rubin; Fiona Fennessy; Wei Huang; Nola Hylton; Brian D Ross
Journal:  Transl Oncol       Date:  2014-02-01       Impact factor: 4.243

7.  Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

Authors:  Octavia Bane; Stefanie J Hectors; Mathilde Wagner; Lori L Arlinghaus; Madhava P Aryal; Yue Cao; Thomas L Chenevert; Fiona Fennessy; Wei Huang; Nola M Hylton; Jayashree Kalpathy-Cramer; Kathryn E Keenan; Dariya I Malyarenko; Robert V Mulkern; David C Newitt; Stephen E Russek; Karl F Stupic; Alina Tudorica; Lisa J Wilmes; Thomas E Yankeelov; Yi-Fei Yen; Michael A Boss; Bachir Taouli
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

8.  Four-dimensional transcatheter intraarterial perfusion (TRIP)-MRI for monitoring liver tumor embolization in VX2 rabbits.

Authors:  Dingxin Wang; Sumeet Virmani; Richard Tang; Barbara Szolc-Kowalska; Gayle Woloschak; Reed A Omary; Andrew C Larson
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

9.  Rapid 3D radiofrequency field mapping using catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Andrew C Larson
Journal:  NMR Biomed       Date:  2009-10       Impact factor: 4.044

10.  Use of cardiac output to improve measurement of input function in quantitative dynamic contrast-enhanced MRI.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Qun Chen; Pippa Storey; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.