Literature DB >> 24772207

Biases in Multicenter Longitudinal PET Standardized Uptake Value Measurements.

Robert K Doot1, Larry A Pierce2, Darrin Byrd2, Brian Elston2, Keith C Allberg3, Paul E Kinahan2.   

Abstract

This study investigates measurement biases in longitudinal positron-emission tomography/computed tomography (PET/CT) studies that are due to instrumentation variability including human error. Improved estimation of variability between patient scans is of particular importance for assessing response to therapy and multicenter trials. We used National Institute of Standards and Technology-traceable calibration methodology for solid germanium-68/gallium-68 ((68)Ge/(68)Ga) sources used as surrogates for fluorine-18 ((18)F) in radionuclide activity calibrators. One cross-calibration kit was constructed for both dose calibrators and PET scanners using the same 9-month half-life batch of (68)Ge/(68)Ga in epoxy. Repeat measurements occurred in a local network of PET imaging sites to assess standardized uptake value (SUV) errors over time for six dose calibrators from two major manufacturers and for six PET/CT scanners from three major manufacturers. Bias in activity measures by dose calibrators ranged from -50% to 9% and was relatively stable over time except at one site that modified settings between measurements. Bias in activity concentration measures by PET scanners ranged from -27% to 13% with a median of 174 days between the six repeat scans (range, 29 to 226 days). Corresponding errors in SUV measurements ranged from -20% to 47%. SUV biases were not stable over time with longitudinal differences for individual scanners ranging from -11% to 59%. Bias in SUV measurements varied over time and between scanner sites. These results suggest that attention should be paid to PET scanner calibration for longitudinal studies and use of dose calibrator and scanner cross-calibration kits could be helpful for quality assurance and control.

Entities:  

Year:  2014        PMID: 24772207      PMCID: PMC3998681          DOI: 10.1593/tlo.13850

Source DB:  PubMed          Journal:  Transl Oncol        ISSN: 1936-5233            Impact factor:   4.243


  15 in total

1.  Variability in PET quantitation within a multicenter consortium.

Authors:  Frederic H Fahey; Paul E Kinahan; Robert K Doot; Mehmet Kocak; Harold Thurston; Tina Young Poussaint
Journal:  Med Phys       Date:  2010-07       Impact factor: 4.071

Review 2.  A systematic review of the factors affecting accuracy of SUV measurements.

Authors:  Michael C Adams; Timothy G Turkington; Joshua M Wilson; Terence Z Wong
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

3.  Instrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT.

Authors:  R K Doot; J S Scheuermann; P E Christian; J S Karp; P E Kinahan
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

Review 4.  Technology Insight: advances in molecular imaging and an appraisal of PET/CT scanning.

Authors:  Wolfgang A Weber; Anca L Grosu; Johannes Czernin
Journal:  Nat Clin Pract Oncol       Date:  2008-03

Review 5.  Standards for PET image acquisition and quantitative data analysis.

Authors:  Ronald Boellaard
Journal:  J Nucl Med       Date:  2009-04-20       Impact factor: 10.057

6.  Development of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.

Authors:  Brian E Zimmerman; Jeffrey T Cessna
Journal:  J Nucl Med       Date:  2010-03       Impact factor: 10.057

Review 7.  Progress and promise of FDG-PET imaging for cancer patient management and oncologic drug development.

Authors:  Gary J Kelloff; John M Hoffman; Bruce Johnson; Howard I Scher; Barry A Siegel; Edward Y Cheng; Bruce D Cheson; Joyce O'shaughnessy; Kathryn Z Guyton; David A Mankoff; Lalitha Shankar; Steven M Larson; Caroline C Sigman; Richard L Schilsky; Daniel C Sullivan
Journal:  Clin Cancer Res       Date:  2005-04-15       Impact factor: 12.531

Review 8.  Positron emission tomography-computed tomography standardized uptake values in clinical practice and assessing response to therapy.

Authors:  Paul E Kinahan; James W Fletcher
Journal:  Semin Ultrasound CT MR       Date:  2010-12       Impact factor: 1.875

Review 9.  From RECIST to PERCIST: Evolving Considerations for PET response criteria in solid tumors.

Authors:  Richard L Wahl; Heather Jacene; Yvette Kasamon; Martin A Lodge
Journal:  J Nucl Med       Date:  2009-05       Impact factor: 10.057

10.  FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0.

Authors:  Ronald Boellaard; Mike J O'Doherty; Wolfgang A Weber; Felix M Mottaghy; Markus N Lonsdale; Sigrid G Stroobants; Wim J G Oyen; Joerg Kotzerke; Otto S Hoekstra; Jan Pruim; Paul K Marsden; Klaus Tatsch; Corneline J Hoekstra; Eric P Visser; Bertjan Arends; Fred J Verzijlbergen; Josee M Zijlstra; Emile F I Comans; Adriaan A Lammertsma; Anne M Paans; Antoon T Willemsen; Thomas Beyer; Andreas Bockisch; Cornelia Schaefer-Prokop; Dominique Delbeke; Richard P Baum; Arturo Chiti; Bernd J Krause
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-01       Impact factor: 9.236

View more
  18 in total

1.  Longitudinal monitoring of reconstructed activity concentration on a clinical time-of-flight PET/CT scanner.

Authors:  Lawrence R MacDonald; Amy E Perkins; Chi-Hua Tung
Journal:  J Med Imaging (Bellingham)       Date:  2016-11-23

2.  Measuring temporal stability of positron emission tomography standardized uptake value bias using long-lived sources in a multicenter network.

Authors:  Darrin Byrd; Rebecca Christopfel; Grae Arabasz; Ciprian Catana; Joel Karp; Martin A Lodge; Charles Laymon; Eduardo G Moros; Mikalai Budzevich; Sadek Nehmeh; Joshua Scheuermann; John Sunderland; Jun Zhang; Paul Kinahan
Journal:  J Med Imaging (Bellingham)       Date:  2018-01-04

3.  Multicenter survey of PET/CT protocol parameters that affect standardized uptake values.

Authors:  Darrin Byrd; Rebecca Christopfel; John Buatti; Eduardo Moros; Sadek Nehmeh; Adam Opanowski; Paul Kinahan
Journal:  J Med Imaging (Bellingham)       Date:  2017-12-08

4.  Multimodality molecular imaging of the lung.

Authors:  Delphine L Chen; Paul E Kinahan
Journal:  Clin Transl Imaging       Date:  2014-10-16

Review 5.  Qualification of National Cancer Institute-Designated Cancer Centers for Quantitative PET/CT Imaging in Clinical Trials.

Authors:  Joshua S Scheuermann; Janet S Reddin; Adam Opanowski; Paul E Kinahan; Barry A Siegel; Lalitha K Shankar; Joel S Karp
Journal:  J Nucl Med       Date:  2017-03-02       Impact factor: 10.057

6.  Hot spot imaging in cardiovascular diseases: an information statement from SNMMI, ASNC, and EANM.

Authors:  Brett W Sperry; Timothy M Bateman; Esma A Akin; Paco E Bravo; Wengen Chen; Vasken Dilsizian; Fabien Hyafil; Yiu Ming Khor; Robert J H Miller; Riemer H J A Slart; Piotr Slomka; Hein Verberne; Edward J Miller; Chi Liu
Journal:  J Nucl Cardiol       Date:  2022-07-21       Impact factor: 3.872

Review 7.  Quantitative Imaging in Cancer Clinical Trials.

Authors:  Thomas E Yankeelov; David A Mankoff; Lawrence H Schwartz; Frank S Lieberman; John M Buatti; James M Mountz; Bradley J Erickson; Fiona M M Fennessy; Wei Huang; Jayashree Kalpathy-Cramer; Richard L Wahl; Hannah M Linden; Paul E Kinahan; Binsheng Zhao; Nola M Hylton; Robert J Gillies; Laurence Clarke; Robert Nordstrom; Daniel L Rubin
Journal:  Clin Cancer Res       Date:  2016-01-15       Impact factor: 12.531

8.  Long-term stability of carrier-added (68)Ge standardized solutions.

Authors:  B E Zimmerman; D E Bergeron; R Fitzgerald; J T Cessna
Journal:  Appl Radiat Isot       Date:  2015-11-26       Impact factor: 1.513

9.  Two determinations of the Ge-68 half-life.

Authors:  Denis E Bergeron; Jeffrey T Cessna; Brian E Zimmerman
Journal:  Appl Radiat Isot       Date:  2017-10-20       Impact factor: 1.513

10.  Test-Retest Reproducibility of 18F-FDG PET/CT Uptake in Cancer Patients Within a Qualified and Calibrated Local Network.

Authors:  Brenda F Kurland; Lanell M Peterson; Andrew T Shields; Jean H Lee; Darrin W Byrd; Alena Novakova-Jiresova; Mark Muzi; Jennifer M Specht; David A Mankoff; Hannah M Linden; Paul E Kinahan
Journal:  J Nucl Med       Date:  2018-10-25       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.