Literature DB >> 26671789

Long-term stability of carrier-added (68)Ge standardized solutions.

B E Zimmerman1, D E Bergeron2, R Fitzgerald2, J T Cessna2.   

Abstract

Tests for chemical stability were carried out on carrier-added (68)Ge solutions prepared and calibrated in 2007 and 2011 to evaluate the suitability of the specific composition as a potential Standard Reference Material. Massic count rates of the stored solutions were measured using a NaI(Tl) well counter before and after gravimetric transfers. The present activity concentration of the 2007 solution was also measured using live-timed anticoincidence counting (LTAC) and compared to the 2007 calibrated value. The well counter data indicated no change in massic count rate to within uncertainties for either solution. The LTAC measurements gave a difference of -0.49% in the activity concentration 2007 solution over 7 years. However, the uncertainty in the decay correction over that time, due to the uncertainty in the (68)Ge half-life, accounted for the majority (0.67% out of 0.83%) of the standard uncertainty on the activity concentration. The results indicate that these carrier-added solutions are stable with regard to potential activity losses over several half-lives of (68)Ge. Published by Elsevier Ltd.

Entities:  

Keywords:  Germanium-68; Reference materials; Solution stability

Year:  2015        PMID: 26671789      PMCID: PMC5123690          DOI: 10.1016/j.apradiso.2015.11.078

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  6 in total

1.  Standardization of 68(Ge+Ga).

Authors:  E L Grigorescu; C D Negut; A Luca; Anamaria Cristina Razdolescu; Mioara Tanase
Journal:  Appl Radiat Isot       Date:  2004 Feb-Apr       Impact factor: 1.513

2.  Development of a traceable calibration methodology for solid (68)Ge/(68)Ga sources used as a calibration surrogate for (18)F in radionuclide activity calibrators.

Authors:  Brian E Zimmerman; Jeffrey T Cessna
Journal:  J Nucl Med       Date:  2010-03       Impact factor: 10.057

3.  Biases in Multicenter Longitudinal PET Standardized Uptake Value Measurements.

Authors:  Robert K Doot; Larry A Pierce; Darrin Byrd; Brian Elston; Keith C Allberg; Paul E Kinahan
Journal:  Transl Oncol       Date:  2014-02-01       Impact factor: 4.243

4.  Microwave-supported preparation of (68)Ga bioconjugates with high specific radioactivity.

Authors:  I Velikyan; G J Beyer; B Långström
Journal:  Bioconjug Chem       Date:  2004 May-Jun       Impact factor: 4.774

Review 5.  (68)Ge/ (68)Ga generators: past, present, and future.

Authors:  F Rösch
Journal:  Recent Results Cancer Res       Date:  2013

6.  Standardization of (68)Ge/(68)Ga Using Three Liquid Scintillation Counting Based Methods.

Authors:  B E Zimmerman; J T Cessna; R Fitzgerald
Journal:  J Res Natl Inst Stand Technol       Date:  2008-10-01
  6 in total
  1 in total

1.  Two determinations of the Ge-68 half-life.

Authors:  Denis E Bergeron; Jeffrey T Cessna; Brian E Zimmerman
Journal:  Appl Radiat Isot       Date:  2017-10-20       Impact factor: 1.513

  1 in total