Literature DB >> 24771261

Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs.

Michael T LaCour1, Adrija Sharma, Christopher B Carr, Richard D Komistek, Douglas A Dennis.   

Abstract

BACKGROUND: Posterior-stabilized rotating-platform prostheses for TKAs were designed to improve contact mechanics at the femoral-polyethylene (PE) interface. Short-term followup studies have shown that the PE bearings rotate with respect to the tibia but might not necessarily track with the femur. It is important to know how kinematics in these designs change owing to long-term in vivo use. QUESTIONS/PURPOSES: We asked whether there is a significant change in the in vivo kinematic performance of a posterior-stabilized rotating-platform prosthesis at as much as 10 years postoperative. We specifically examined (1) relative femoral component-PE bearing and relative PE bearing-tibial tray motion; (2) relative AP motion of the femoral condyles with respect to the tibial tray; and (3) relative femorotibial condylar translations.
METHODS: In vivo three-dimensional kinematics were evaluated for eight patients at 3 months, 15 months, 5 years, and 10 years after TKA with primary implantation of a posterior-stabilized rotating-platform prosthesis. Each patient performed deep knee bend activity, and three-dimensional kinematics were reconstructed from multiple fluoroscopic images using a three-dimensional to two-dimensional registration technique. Once complete, relative component axial rotation patterns, medial and lateral condyle motions throughout flexion, and the presence of femoral condylar lift-off were analyzed.
RESULTS: Overall, tibial bearing rotation was maintained at 10 years postoperatively. There was no statistical difference between postoperative periods for any kinematic parameter except for femoral component-PE bearing axial rotation, which was reduced at the 10-year evaluation versus other assessment periods (p = 0.0006). The lack of statistical difference between postoperative evaluation periods indicates sustained overall implant kinematic performance.
CONCLUSIONS: Our study showed that PE bearing-tibial tray mobility was maintained and that femoral component-PE bearing rotation was reduced at the 10-year followup. This suggests that the overall kinematic performance of this mobile-bearing implant is not negatively affected 10 years postoperatively. LEVEL OF EVIDENCE: Level III, retrospective study. See the Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2014        PMID: 24771261      PMCID: PMC4117897          DOI: 10.1007/s11999-014-3642-6

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  29 in total

1.  Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy.

Authors:  William A. Hoff; Richard D. Komistek; Douglas A. Dennis; Stefan M. Gabriel; Scott A. Walker
Journal:  Clin Biomech (Bristol, Avon)       Date:  1998-10       Impact factor: 2.063

2.  Multicenter determination of in vivo kinematics after total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Brian D Haas; James B Stiehl
Journal:  Clin Orthop Relat Res       Date:  2003-11       Impact factor: 4.176

3.  A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images.

Authors:  Mohamed R Mahfouz; William A Hoff; Richard D Komistek; Douglas A Dennis
Journal:  IEEE Trans Med Imaging       Date:  2003-12       Impact factor: 10.048

4.  In vivo fluoroscopic analysis of fixed-bearing total knee replacements.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz
Journal:  Clin Orthop Relat Res       Date:  2003-05       Impact factor: 4.176

5.  Tibiofemoral contact stress after total knee arthroplasty: comparison of fixed and mobile-bearing inlay designs.

Authors:  Christina Stukenborg-Colsman; Sven Ostermeier; Christof Hurschler; Carl Joachim Wirth
Journal:  Acta Orthop Scand       Date:  2002-12

6.  Mobile-bearing total knee arthroplasty: do the polyethylene bearings rotate?

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Joel T Outten; Adrija Sharma
Journal:  Clin Orthop Relat Res       Date:  2005-11       Impact factor: 4.176

7.  Polyethylene contact stresses, articular congruity, and knee alignment.

Authors:  D D D'Lima; P C Chen; C W Colwell
Journal:  Clin Orthop Relat Res       Date:  2001-11       Impact factor: 4.176

8.  The New Jersey Low-Contact-Stress Knee Replacement System: biomechanical rationale and review of the first 123 cemented cases.

Authors:  F F Buechel; M J Pappas
Journal:  Arch Orthop Trauma Surg       Date:  1986

9.  In vivo kinematics for subjects with and without an anterior cruciate ligament.

Authors:  Richard D Komistek; Jerome Allain; Dylan T Anderson; Douglas A Dennis; Daniel Goutallier
Journal:  Clin Orthop Relat Res       Date:  2002-11       Impact factor: 4.176

10.  A multicenter analysis of axial femorotibial rotation after total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Mohamed R Mahfouz; Scott A Walker; Abby Tucker
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

View more
  4 in total

1.  Mobility of the rotating platform in low contact stress knee arthroplasty is durable.

Authors:  Arthur Zürcher; Kim van Hutten; Jaap Harlaar; Ruud Pöll
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-10-16       Impact factor: 4.342

2.  Long-term outcome of low contact stress total knee arthroplasty with different mobile bearing designs.

Authors:  Giuseppe Solarino; Antonio Spinarelli; Massimiliano Carrozzo; Andrea Piazzolla; Giovanni Vicenti; Biagio Moretti
Journal:  Joints       Date:  2014-08-01

3.  Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation.

Authors:  Tilman Pfitzner; Philippe Moewis; Patrick Stein; Heide Boeth; Adam Trepczynski; Philipp von Roth; Georg N Duda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-06-27       Impact factor: 4.342

4.  Are TKA Kinematics During Closed Kinetic Chain Exercises Associated with Patient-reported Outcomes? A Preliminary Analysis.

Authors:  Stefaan Van Onsem; Matthias Verstraete; Wies Van Eenoo; Catherine Van Der Straeten; Jan Victor
Journal:  Clin Orthop Relat Res       Date:  2020-02       Impact factor: 4.755

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.