Literature DB >> 12771822

In vivo fluoroscopic analysis of fixed-bearing total knee replacements.

Douglas A Dennis1, Richard D Komistek, Mohamed R Mahfouz.   

Abstract

In vivo kinematic patterns were determined for subjects (patients participating in the study), having either a fixed-bearing posterior-stabilized or posterior cruciate-retaining total knee arthroplasty. While under fluoroscopic surveillance, subjects did normal gait and a deep knee bend. Video images were downloaded to a workstation computer and analyzed in three dimensions using an iterative model-fitting approach. Femorotibial contact paths for the medial and lateral condyles, axial rotation, and condylar lift-off were determined. During a deep knee bend, subjects having a posterior-stabilized total knee arthroplasty routinely experienced posterior femoral rollback of their lateral condyle and normal axial rotational patterns, whereas random subjects having a posterior cruciate-retaining total knee arthroplasty experienced paradoxical anterior sliding and opposite axial rotational patterns. During gait, posterior-stabilized and posterior cruciate-retaining total knee arthroplasties experienced similar kinematic patterns, with the presence of paradoxical sliding and opposite axial rotational patterns. Subjects having posterior-stabilized and posterior cruciate-retaining total knee arthroplasties experienced condylar lift-off. Subjects having a posterior cruciate-retaining total knee arthroplasty predominantly experienced lateral condylar lift-off whereas subjects with posterior-stabilized total knee arthroplasties experienced either medial or lateral condylar lift-off. Subjects having a posterior-stabilized total knee arthroplasty experienced significantly greater weightbearing range of motion.

Entities:  

Mesh:

Year:  2003        PMID: 12771822     DOI: 10.1097/01.blo.0000062385.79828.72

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  43 in total

1.  No difference in anterior tibial translation with and without posterior cruciate ligament in less invasive total knee replacement.

Authors:  Bernhard Christen; Michal Neukamp; Emin Aghayev
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-01       Impact factor: 4.342

2.  The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

Authors:  Xiaojun Shi; Bin Shen; Pengde Kang; Jing Yang; Zongke Zhou; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-02       Impact factor: 4.342

3.  Posterior stabilized TKA reduce patellofemoral contact pressure compared with cruciate retaining TKA in vitro.

Authors:  Christoph Becher; Thomas J Heyse; Nadine Kron; Sven Ostermeier; Christof Hurschler; Markus D Schofer; Susanne Fuchs-Winkelmann; Carsten O Tibesku
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-03-21       Impact factor: 4.342

4.  Gap balancing versus measured resection technique for total knee arthroplasty.

Authors:  Douglas A Dennis; Richard D Komistek; Raymond H Kim; Adrija Sharma
Journal:  Clin Orthop Relat Res       Date:  2010-01       Impact factor: 4.176

5.  Intra-operative gaps affect outcome and postoperative kinematics in vivo following cruciate-retaining total knee arthroplasty.

Authors:  Eisaku Fujimoto; Yoshiaki Sasashige; Tetsuya Tomita; Hirofumi Sasaki; Yoriko Touten; Yuusuke Fujiwara; Mitsuo Ochi
Journal:  Int Orthop       Date:  2015-07-02       Impact factor: 3.075

6.  Association between anteroposterior laxity in mid-range flexion and subjective healing of instability after total knee arthroplasty.

Authors:  Tomoharu Mochizuki; Osamu Tanifuji; Takashi Sato; Hiroki Hijikata; Hiroshi Koga; Satoshi Watanabe; Yukimasa Higano; Akihiro Ariumi; Takayuki Murayama; Hiroshi Yamagiwa; Naoto Endo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-09       Impact factor: 4.342

7.  ACL substitution may improve kinematics of PCL-retaining total knee arthroplasty.

Authors:  Thomas Zumbrunn; Michael P Duffy; Harry E Rubash; Henrik Malchau; Orhun K Muratoglu; Kartik Mangudi Varadarajan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-11-11       Impact factor: 4.342

8.  The ACL in the arthritic knee: how often is it present and can preoperative tests predict its presence?

Authors:  Aaron J Johnson; Stephen M Howell; Christopher R Costa; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

9.  Plain radiographs underestimate the asymmetry of the posterior condylar offset of the knee compared with MRI.

Authors:  Pramod B Voleti; Jason W Stephenson; Paul A Lotke; Gwo-Chin Lee
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

10.  Confirmation of long-term in vivo bearing mobility in eight rotating-platform TKAs.

Authors:  Michael T LaCour; Adrija Sharma; Christopher B Carr; Richard D Komistek; Douglas A Dennis
Journal:  Clin Orthop Relat Res       Date:  2014-04-26       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.