Literature DB >> 24766866

Dynamic contour tonometry over silicone hydrogel contact lens.

Andrew K C Lam1, Jimmy S H Tse2.   

Abstract

PURPOSE: This study compared the measurements of intraocular pressure (IOP) and ocular pulse amplitude (OPA) using the Dynamic Contour Tonometry (DCT) over silicone hydrogel contact lenses of different modulus. Corneal biomechanics were also measured using the Ocular Response Analyzer (ORA).
METHODS: Forty-seven young (mean age 22.3 years, standard deviation 1.2 years) subjects had IOP, OPA, corneal hysteresis (CH) and corneal resistance factor (CRF) measured without lens and with two brands of silicone hydrogel contact lenses. Each eye wore one brand followed by another, randomly assigned, and then the lenses switched over. Difference and agreement of IOP and OPA with and without silicone hydrogel contact lens were studied.
RESULTS: The right and left eyes had similar corneal curvatures, central corneal thicknesses, IOP, OPA and corneal biomechanics at baseline. No significant difference was found in CH and CRF when they were measured over different contact lenses. IOP demonstrated a greater difference (95% limits of agreement: 2.73mmHg) compared with no lens when it was measured over high modulus silicone hydrogel lenses. Agreement improved over low lens modulus silicone hydrogel lenses (95% limits of agreement: 2.2-2.4mmHg). 95% limits of agreement were within 1.0mmHg for OPA.
CONCLUSIONS: This study demonstrated the feasibility of DCT over silicone hydrogel lenses. Low lens modulus silicone hydrogel contact lens in situ has no clinical effect on DCT.
Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

Entities:  

Keywords:  Amplitud del pulso ocular; Corneal hysteresis; Corneal resistance factor; Factor de resistencia corneal; Histéresis corneal; Intraocular pressure; Lens modulus; Módulo de la lente; Ocular pulse amplitude; Presión intraocular

Mesh:

Substances:

Year:  2013        PMID: 24766866      PMCID: PMC4009514          DOI: 10.1016/j.optom.2013.07.005

Source DB:  PubMed          Journal:  J Optom        ISSN: 1989-1342


  40 in total

1.  Comparison of conventional and silicone hydrogel contact lenses for bullous keratoplasty.

Authors:  Natasha Lim; Ursula Vogt
Journal:  Eye Contact Lens       Date:  2006-09       Impact factor: 2.018

2.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

3.  Ocular pulse amplitude in healthy subjects as measured by dynamic contour tonometry.

Authors:  Claude Kaufmann; Lucas M Bachmann; Yves C Robert; Michael A Thiel
Journal:  Arch Ophthalmol       Date:  2006-08

4.  Corneal biomechanical properties in normal, post-laser in situ keratomileusis, and keratoconic eyes.

Authors:  Dolores Ortiz; David Piñero; Mohamed H Shabayek; Francisco Arnalich-Montiel; Jorge L Alió
Journal:  J Cataract Refract Surg       Date:  2007-08       Impact factor: 3.351

5.  Comparative study of two silicone hydrogel contact lenses used as bandage contact lenses after LASEK.

Authors:  Raquel Gil-Cazorla; Miguel A Teus; Jose L Hernández-Verdejo; Laura De Benito-Llopis; Monsterrat García-González
Journal:  Optom Vis Sci       Date:  2008-09       Impact factor: 1.973

6.  Clinical comparison of the Keeler Pulsair 2000, American Optical MkII and Goldmann applanation tonometers.

Authors:  S W Mackie; J L Jay; R Ackerley; G Walsh
Journal:  Ophthalmic Physiol Opt       Date:  1996-03       Impact factor: 3.117

7.  Effects of body mass index on intraocular pressure and ocular pulse amplitude.

Authors:  Remzi Karadag; Zeynel Arslanyilmaz; Bahri Aydin; Ibrahim F Hepsen
Journal:  Int J Ophthalmol       Date:  2012-10-18       Impact factor: 1.779

8.  Intra- and postoperative variation in ocular response analyzer parameters in keratoconic eyes after corneal cross-linking.

Authors:  Paolo Vinciguerra; Elena Albè; Ashraf M Mahmoud; Silvia Trazza; Farhad Hafezi; Cynthia J Roberts
Journal:  J Refract Surg       Date:  2010-04-15       Impact factor: 3.573

9.  Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis.

Authors:  Claude Kaufmann; Lucas M Bachmann; Michael A Thiel
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-09       Impact factor: 4.799

10.  Dynamic contour tonometry in comparison to intracameral IOP measurements.

Authors:  Andreas G Boehm; Anja Weber; Lutz E Pillunat; Rainer Koch; Eberhard Spoerl
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-03-03       Impact factor: 4.799

View more
  3 in total

1.  Rebound Tonometry over Soft Contact Lenses.

Authors:  Iva Krolo; Boze Mihaljevic; Aida Kasumovic; Freja Bagatin; Maja Malenica Ravlic; Jelena Skunca Herman
Journal:  Acta Inform Med       Date:  2020-09

2.  The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry.

Authors:  Fabrizio Zeri; Mario De Cusatis; Luigi Lupelli; Peter Graham Swann
Journal:  J Optom       Date:  2015-10-21

3.  Age-Related Variations of Rabbit Corneal Geometrical and Clinical Biomechanical Parameters.

Authors:  Haixia Zhang; Xiao Qin; Xiaomeng Cao; Di Zhang; Lin Li
Journal:  Biomed Res Int       Date:  2017-08-13       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.