A geometric calibration method for cone beam CT systems.

Kai Yang1, Alexander L C Kwan, DeWitt F Miller, John M Boone.   

Abstract

Cone beam CT systems are being deployed in large numbers for small animal imaging, dental imaging, and other specialty applications. A new high-precision method for cone beam CT system calibration is presented in this paper. It uses multiple projection images acquired from rotating point-like objects (metal ball bearings) and the angle information generated from the rotating gantry system is also used. It is assumed that the whole system has a mechanically stable rotation center and that the detector does not have severe out-of-plane rotation (<2 degrees). Simple geometrical relationships between the orbital paths of individual BBs and five system parameters were derived. Computer simulations were employed to validate the accuracy of this method in the presence of noise. Equal or higher accuracy was achieved compared with previous methods. This method was implemented for the geometrical calibration of both a micro CT scanner and a breast CT scanner. The reconstructed tomographic images demonstrated that the proposed method is robust and easy to implement with high precision.

Mesh:

Year:  2006        PMID: 16872077      PMCID: PMC2840998          DOI: 10.1118/1.2198187

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Three-dimensional artifact induced by projection weighting and misalignment.

Authors:  J Hsieh
Journal:  IEEE Trans Med Imaging       Date:  1999-04       Impact factor: 10.048

2.  Implementation of a cone-beam reconstruction algorithm for the single-circle source orbit with embedded misalignment correction using homogeneous coordinates.

Authors:  M Karolczak; S Schaller; K Engelke; A Lutz; U Taubenreuther; K Wiesent; W Kalender
Journal:  Med Phys       Date:  2001-10       Impact factor: 4.071

3.  Alignment of a volumetric tomography system.

Authors:  G M Stevens; R Saunders; N J Pelc
Journal:  Med Phys       Date:  2001-07       Impact factor: 4.071

4.  Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography.

Authors:  F Noo; R Clackdoyle; C Mennessier; T A White; T J Roney
Journal:  Phys Med Biol       Date:  2000-11       Impact factor: 3.609

5.  Geometric misalignment and calibration in cone-beam tomography.

Authors:  Lorenz von Smekal; Marc Kachelriess; Elizaveta Stepina; Willi A Kalender
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

6.  Accurate technique for complete geometric calibration of cone-beam computed tomography systems.

Authors:  Youngbin Cho; Douglas J Moseley; Jeffrey H Siewerdsen; David A Jaffray
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

7.  Estimation of geometrical parameters and collimator evaluation for cone beam tomography.

Authors:  G T Gullberg; B M Tsui; C R Crawford; J G Ballard; J T Hagius
Journal:  Med Phys       Date:  1990 Mar-Apr       Impact factor: 4.071

  7 in total
  38 in total

1.  A dual micro-CT system for small animal imaging.

Authors:  C T Badea; S Johnston; B Johnson; M Lin; L W Hedlund; G Allan Johnson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008-04-18

2.  Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy.

Authors:  Weiliang Du; Song Gao; Xiaochun Wang; Rajat J Kudchadker
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Systematic calibration of an integrated x-ray and optical tomography system for preclinical radiation research.

Authors:  Yidong Yang; Ken Kang-Hsin Wang; Sohrab Eslami; Iulian I Iordachita; Michael S Patterson; John W Wong
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

4.  Computer modeling of the spatial resolution properties of a dedicated breast CT system.

Authors:  Kai Yang; Alexander L C Kwan; John M Boone
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

5.  A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

Authors:  Martin G Wagner; Charles R Hatt; David A P Dunkerley; Lindsay E Bodart; Amish N Raval; Michael A Speidel
Journal:  Med Phys       Date:  2018-05-03       Impact factor: 4.071

6.  Evaluation of guidewire path reproducibility.

Authors:  Sebastian Schafer; Kenneth R Hoffmann; Peter B Noël; Ciprian N Ionita; Jacek Dmochowski
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

7.  Geometric calibration for a dual tube/detector micro-CT system.

Authors:  Samuel M Johnston; G Allan Johnson; Cristian T Badea
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

9.  The effect of skin thickness determined using breast CT on mammographic dosimetry.

Authors:  Shih-Ying Huang; John M Boone; Kai Yang; Alexander L C Kwan; Nathan J Packard
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

10.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.