Literature DB >> 24720423

Accuracy of digital versus conventional implant impressions.

Sang J Lee1, Rebecca A Betensky, Grace E Gianneschi, German O Gallucci.   

Abstract

OBJECTIVE: The accuracy of digital impressions greatly influences their clinical viability in implant restorations. The aim of this study was to compare the accuracy of gypsum models acquired from the conventional implant impression to digitally milled models created from direct digitalization by three-dimensional analysis.
MATERIALS AND METHODS: Thirty gypsum and 30 digitally milled models, impressed directly from a reference model, were prepared. The models and reference model were scanned by a laboratory scanner, and 30 surface tessellation language datasets from each group were imported to an inspection software program. The datasets were aligned to the reference dataset by a repeated best-fit algorithm, and 10 specified contact locations of interest were measured in mean volumetric deviations. The areas were pooled by cusps, fossae, interproximal contacts, horizontal and vertical axes of implant position and angulation. The pooled areas were statistically analysed by comparing each group to the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision.
RESULTS: Milled models from digital impressions had comparable accuracy to gypsum models from conventional impressions. However, differences in fossae and vertical displacement of the implant position from the gypsum and digitally milled models compared to the reference model exhibited statistical significance (P < 0.001, P = 0.020, respectively).
CONCLUSION: Milled models from digital impression are comparable to gypsum models from conventional impression.
© 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  biomaterial; conventional impression; digital impression; implant restoration

Mesh:

Substances:

Year:  2014        PMID: 24720423      PMCID: PMC4428303          DOI: 10.1111/clr.12375

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  23 in total

1.  Factors influencing optical 3D scanning of vinyl polysiloxane impression materials.

Authors:  R DeLong; M R Pintado; C C Ko; J S Hodges; W H Douglas
Journal:  J Prosthodont       Date:  2001-06       Impact factor: 2.752

2.  The accuracy of dual-arch impressions: a pilot study.

Authors:  Trevor D Larson; Mark A Nielsen; William W Brackett
Journal:  J Prosthet Dent       Date:  2002-06       Impact factor: 3.426

3.  Accuracy of a system for creating 3D computer models of dental arches.

Authors:  R DeLong; M Heinzen; J S Hodges; C-C Ko; W H Douglas
Journal:  J Dent Res       Date:  2003-06       Impact factor: 6.116

4.  Evaluation of dental arch reproduction using three-dimensional optical digitization.

Authors:  M E Brosky; R J Major; R DeLong; J S Hodges
Journal:  J Prosthet Dent       Date:  2003-11       Impact factor: 3.426

5.  In vitro study on passive fit in implant-supported 5-unit fixed partial dentures.

Authors:  Matthias Karl; Werner Winter; Thomas D Taylor; Siegfried M Heckmann
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Jan-Feb       Impact factor: 2.804

6.  Computer-aided analysis of the influence of digitizing and surfacing on the accuracy in dental CAD/CAM technology.

Authors:  Heike Rudolph; Ralph G Luthardt; Michael H Walter
Journal:  Comput Biol Med       Date:  2006-07-17       Impact factor: 4.589

7.  Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations.

Authors:  Sebastian Quaas; Heike Rudolph; Ralph G Luthardt
Journal:  J Dent       Date:  2007-11-05       Impact factor: 4.379

8.  Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study.

Authors:  Heeje Lee; Carlo Ercoli; Paul D Funkenbusch; Changyong Feng
Journal:  J Prosthet Dent       Date:  2008-02       Impact factor: 3.426

9.  An evaluation of impression techniques for osseointegrated implants.

Authors:  M R Spector; T E Donovan; J I Nicholls
Journal:  J Prosthet Dent       Date:  1990-04       Impact factor: 3.426

10.  Tolerance measurements of various implant components.

Authors:  T Ma; J I Nicholls; J E Rubenstein
Journal:  Int J Oral Maxillofac Implants       Date:  1997 May-Jun       Impact factor: 2.804

View more
  25 in total

1.  [Accuracy of three intraoral scans for primary impressions of edentulous jaws].

Authors:  Y Cao; J K Chen; K H Deng; Y Wang; Y C Sun; Y J Zhao
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-02-18

2.  [Effect of disinfectant with benzethon chloramine and isopropanol as main active ingredients on the accuracy of dental impression].

Authors:  D Xu; D H Wei; Y C Zhang; P DI; Y Lin
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-12-18

Review 3.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

4.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

5.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

6.  Evaluation of intraoral digital impressions for obtaining gingival contour in the esthetic zone: accuracy outcomes.

Authors:  Donghao Wei; Ping Di; Jiehua Tian; Yijiao Zhao; Ye Lin
Journal:  Clin Oral Investig       Date:  2019-11-21       Impact factor: 3.573

7.  Dimensional accuracy of cone beam CT with varying angulation of the jaw to the X-ray beam.

Authors:  George K Koch; Adam Hamilton; Kelly Wang; Laura Herschdorfer; Kyu Ha Lee; German O Gallucci; Bernard Friedland
Journal:  Dentomaxillofac Radiol       Date:  2018-11-08       Impact factor: 2.419

8.  Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

Authors:  Ning Gan; Yaoyang Xiong; Ting Jiao
Journal:  PLoS One       Date:  2016-07-06       Impact factor: 3.240

9.  Comparison of Adaptation between the Major Connectors Fabricated from Intraoral Digital Impressions and Extraoral Digital Impressions.

Authors:  Ning Gan; Yaye Ruan; Jian Sun; Yaoyang Xiong; Ting Jiao
Journal:  Sci Rep       Date:  2018-01-11       Impact factor: 4.379

Review 10.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.