Literature DB >> 14982352

In vitro study on passive fit in implant-supported 5-unit fixed partial dentures.

Matthias Karl1, Werner Winter, Thomas D Taylor, Siegfried M Heckmann.   

Abstract

PURPOSE: Fabrication and retention methods have an influence on the passivity of superstructure fit. The objective of the study was to quantify the strain development of various cemented and screw-retained fixed partial dentures (FPDs).
MATERIALS AND METHODS: Forty samples of 4 different types of FPDs (10 of each type) were investigated. Each sample had 3 ITI implant abutments and 2 pontics. The 3 implants were anchored in a straight-line configuration in a measurement model simulating a real-life patient situation. Strain gauges were mounted close to the implants and on the pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate 2-sample tests were performed, with the level of significance set at P = .1.
RESULTS: All FPDs investigated revealed a considerable amount of strain, with no significant difference between cement and screw retention. Furthermore, no significant difference was found between the conventional fabrication modes for screw-retained FPDs. The lowest strains were found in prostheses that were intraorally bonded onto gold cylinders. DISCUSSION: Because bonding of the superstructure in the oral cavity may compensate for impression and laboratory variables, restorations with the best possible passive fit can result from this retention technique. Before this technique can be recommended, the long-term stability of the adhesive layer should be investigated.
CONCLUSIONS: As an absolute passive fit of superstructures is not possible using conventional clinical and laboratory procedures, and as clinical fit-evaluation methods often do not detect "hidden" inaccuracies, the more sensitive strain-gauge technique should be utilized for an objective accuracy test. Reference strain values from implant-supported prostheses that have served without complications could help define a "biologically acceptable fit.

Entities:  

Mesh:

Year:  2004        PMID: 14982352

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  18 in total

1.  An experimental and theoretical composite model of the human mandible.

Authors:  R De Santis; F Mollica; R Esposito; L Ambrosio; L Nicolais
Journal:  J Mater Sci Mater Med       Date:  2005-12       Impact factor: 3.896

2.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

3.  Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis.

Authors:  Seok-Gyu Kim; Chae-Heon Chung; Mee-Kyoung Son
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

4.  A Finite Element Stress Analysis of a Concical Triangular Connection in Implants: A New Proposal.

Authors:  Romy Angeles Maslucan; John Alexis Dominguez
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

5.  Accuracy of digital versus conventional implant impressions.

Authors:  Sang J Lee; Rebecca A Betensky; Grace E Gianneschi; German O Gallucci
Journal:  Clin Oral Implants Res       Date:  2014-04-10       Impact factor: 5.977

6.  Vertical misfit of laser-sintered and vacuum-cast implant-supported crown copings luted with definitive and temporary luting agents.

Authors:  Raquel Castillo-de-Oyagüe; Andrés Sánchez-Turrión; José-Francisco López-Lozano; Alberto Albaladejo; Daniel Torres-Lagares; Javier Montero; Maria-Jesús Suárez-García
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-07-01

7.  Strain of implants depending on occlusion types in mandibular implant-supported fixed prostheses.

Authors:  Byoung-Sup Sohn; Seong-Joo Heo; Jai-Young Koak; Seong-Kyun Kim; Su-Young Lee
Journal:  J Adv Prosthodont       Date:  2011-03-31       Impact factor: 1.904

8.  The "Toronto prosthesis", an appealing method for restoring patients candidates for hybrid overdentures: A case report.

Authors:  Javier Montero; Carla Macedo de Paula; Alberto Albaladejo
Journal:  J Clin Exp Dent       Date:  2012-12-01

Review 9.  Evaluation of Implant Collar Surfaces for Marginal Bone Loss: A Systematic Review and Meta-Analysis.

Authors:  Roodabeh Koodaryan; Ali Hafezeqoran
Journal:  Biomed Res Int       Date:  2016-07-14       Impact factor: 3.411

10.  Comparative study on stress distribution around internal tapered connection implants according to fit of cement- and screw-retained prostheses.

Authors:  Mi-Young Lee; Seong-Joo Heo; Eun-Jin Park; Ji-Man Park
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.