Literature DB >> 17980951

Direct mechanical data acquisition of dental impressions for the manufacturing of CAD/CAM restorations.

Sebastian Quaas1, Heike Rudolph, Ralph G Luthardt.   

Abstract

OBJECTIVES: The basic prerequisite for the production of dental restorations by means of CAD/CAM technologies is the data acquisition (digitization). Currently, two methods are available, i.e. the extraoral digitization of master casts and the direct intraoral data acquisition. However, it seems to be beneficial to immediately digitize impressions directly at the dental office in order to combine the high precision of mechanical digitizing methods and to shorten the production process. The aim of this study was to investigate the measurement uncertainty (+/-2sigma) and the three-dimensional accuracy of the immediate tactile in-office digitization of dental impressions and of the mechanical digitizing of ceramic master dies using a high-precision touch-probe digitizer.
METHODS: The experimental set-up consisted of ceramic master dies representing tooth 13 and 36 as well as their identical virtual models (CAD models). Fifteen one-step putty-wash impressions were taken from each tooth. The impressions as well as the ceramic master dies were digitized applying a standardized procedure. The datasets were aligned to the corresponding CAD models; then, a computer-aided three-dimensional analysis was performed.
RESULTS: The digitizing of the dental impressions showed a measurement uncertainty of 5.8, mean positive deviations between 27 and 28microm, and mean negative deviations between -21 and -31microm. The digitizing of the ceramic master dies showed a measurement uncertainty of 2.8, mean positive deviations between 7.7 and 9.1microm, and mean negative deviations between -8.5 and -8.8microm.
CONCLUSION: Mechanical digitizers show a very low measurement uncertainty and a high precision. The immediate tactile in-office digitization of impressions cannot be recommended as adequate data acquisition method for CAD/CAM restorations. It is recommendable to digitize clinical sites extraorally, i.e. after taking an impression and fabricating a model cast thereof.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17980951     DOI: 10.1016/j.jdent.2007.08.008

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  21 in total

1.  A new method for the evaluation of the accuracy of full-arch digital impressions in vitro.

Authors:  Jan-Frederik Güth; Daniel Edelhoff; Josef Schweiger; Christine Keul
Journal:  Clin Oral Investig       Date:  2015-10-10       Impact factor: 3.573

2.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

3.  Accuracy of full-arch scans using intraoral scanners.

Authors:  Sebastian B M Patzelt; Archontia Emmanouilidi; Susanne Stampf; Joerg R Strub; Wael Att
Journal:  Clin Oral Investig       Date:  2013-11-17       Impact factor: 3.573

4.  Accuracy of digital models obtained by direct and indirect data capturing.

Authors:  Jan-Frederik Güth; Christine Keul; Michael Stimmelmayr; Florian Beuer; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

5.  Accuracy of digital versus conventional implant impressions.

Authors:  Sang J Lee; Rebecca A Betensky; Grace E Gianneschi; German O Gallucci
Journal:  Clin Oral Implants Res       Date:  2014-04-10       Impact factor: 5.977

6.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

7.  White light scanner-based repeatability of 3-dimensional digitizing of silicon rubber abutment teeth impressions.

Authors:  Jin-Hun Jeon; Kyung-Tak Lee; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2013-11-28       Impact factor: 1.904

8.  Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

Authors:  Jin-Hun Jeon; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

9.  Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner.

Authors:  Jin-Hun Jeon; Dong-Yeon Kim; Jae-Jun Lee; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2016-06-17       Impact factor: 1.904

10.  Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

Authors:  Ning Gan; Yaoyang Xiong; Ting Jiao
Journal:  PLoS One       Date:  2016-07-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.