Literature DB >> 24682595

Prediction of refractive outcome after cataract surgery using partial coherence interferometry: comparison of SRK/T and Haigis formulae.

Rohit Sharma1, P Maharajan, S Kotta, S Maharajan.   

Abstract

To compare the accuracy of the predictions of SRK/T and Haigis formulae, incorporating all the parameters calculated using Zeiss IOLMaster Scan, based on partial coherence interferometry, and to analyse the effect of updating or optimisation of the constants on the post-operative result. A retrospective study was done on 51 consecutive patients, who underwent phacoemulsification by a single surgeon with a temporal corneal incision and a standard Alcon Acrysof MA30 implant in the bag. The pre-operative data were measured using Zeiss IOLMaster scan, and the IOL power calculations were done using both SRK/T and Haigis formulae. The final implant power selection was based on SRK/T predictions. The patients were divided into three groups depending on the axial length, and the post-operative results were analysed at 4 weeks. The difference between the predicted value and the post-operative spherical equivalent was calculated for both the formulae, and a paired t test used for significance. The axial length ranged from 20.93 to 25.16 mm. The error for Haigis was less compared to SRK/T overall and SRK/T resulted in an average hypermetropia 0.69 D and Haigis resulted in an average myopia of 0.16 D. The comparison between SRK/T and Haigis and the updated version of both using the paired t test shows a statistically significant difference, the p values being <0.03 and <0.01, respectively. The updated Haigis Formula with the optimised constants was significantly more accurate than SRK/T formula.

Entities:  

Mesh:

Year:  2014        PMID: 24682595     DOI: 10.1007/s10792-012-9671-9

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  12 in total

1.  Improved prediction of intraocular lens power using partial coherence interferometry.

Authors:  O Findl; W Drexler; R Menapace; H Heinzl; C K Hitzenberger; A F Fercher
Journal:  J Cataract Refract Surg       Date:  2001-06       Impact factor: 3.351

2.  National biometry audit.

Authors:  R P Gale; N Saha; R L Johnston
Journal:  Eye (Lond)       Date:  2004-01       Impact factor: 3.775

3.  Accuracy of the newer generation intraocular lens power calculation formulas in long and short eyes.

Authors:  T Olsen; K Thim; L Corydon
Journal:  J Cataract Refract Surg       Date:  1991-03       Impact factor: 3.351

4.  Development of the SRK/T intraocular lens implant power calculation formula.

Authors:  J A Retzlaff; D R Sanders; M C Kraff
Journal:  J Cataract Refract Surg       Date:  1990-05       Impact factor: 3.351

5.  Comparison of the SRK/T formula and other theoretical and regression formulas.

Authors:  D R Sanders; J A Retzlaff; M C Kraff; H V Gimbel; M G Raanan
Journal:  J Cataract Refract Surg       Date:  1990-05       Impact factor: 3.351

6.  Clinical evaluation of six intraocular lens calculation formulas.

Authors:  S C Richards; R J Olson; W L Richards; R S Brodstein; P N Hale
Journal:  J Am Intraocul Implant Soc       Date:  1985-03

7.  Biometry of 7,500 cataractous eyes.

Authors:  K J Hoffer
Journal:  Am J Ophthalmol       Date:  1980-09       Impact factor: 5.258

8.  [Significance of optic formula selection for postoperative refraction after cataract operation].

Authors:  P C Hoffmann; W W Hütz; H B Eckhardt
Journal:  Klin Monbl Augenheilkd       Date:  1997-09       Impact factor: 0.700

9.  Accuracy of intraocular lens power calculations using the Zeiss IOL master. A prospective study.

Authors:  E Verhulst; J C Vrijghem
Journal:  Bull Soc Belge Ophtalmol       Date:  2001

10.  Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

Authors:  W Haigis; B Lege; N Miller; B Schneider
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-09       Impact factor: 3.117

View more
  4 in total

1.  Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes.

Authors:  Yanjun Hua; Chao Pan; Qinmei Wang
Journal:  Int Ophthalmol       Date:  2019-03-01       Impact factor: 2.031

2.  Haigis and SRKT formulae accuracy for intentional myopic overcorrection.

Authors:  Rodrigo Faeda Dalto; Miriam A Ferreira; Wilian Queiroz; Roberto Pinto Coelho; Jayter Silva Paula; Andre Messias
Journal:  Int Ophthalmol       Date:  2017-06-21       Impact factor: 2.031

3.  Clinical application of bicylindric intraocular lens power calculation method.

Authors:  Jorge A Calvo-Sanz; Cristina Bonnin-Arias; Alfonso Arias-Puente
Journal:  Indian J Ophthalmol       Date:  2020-06       Impact factor: 1.848

4.  The impact of cataract progression on accuracy of intraocular lens power measurement.

Authors:  Lin Leng; Honglei Li; Min Yin; Han Gao; Ting Shao; Keli Long
Journal:  PLoS One       Date:  2021-02-10       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.