Development of the SRK/T intraocular lens implant power calculation formula.

J A Retzlaff1, D R Sanders, M C Kraff.   

Abstract

A new implant power calculation formula (SRK/T) was developed using the nonlinear terms of the theoretical formulas as its foundation but empirical regression methodology for optimization. Postoperative anterior chamber depth prediction, retinal thickness axial length correction, and corneal refractive index were systematically and interactively optimized using an iterative process on five data sets consisting of 1,677 posterior chamber lens cases. The new SRK/T formula performed slightly better than the Holladay, SRK II, Binkhorst, and Hoffer formulas, which was the expected result as any formula performs superiorly with the data from which it was derived. Comparative accuracy of this formula upon independent data sets is addressed in a follow-up report. The formula derived provides a primarily theoretical approach under the SRK umbrella of formulas and has the added advantage of being calculable using either SRK A-constants that have been empirically derived over the last nine years or using anterior chamber depth estimates.

Entities:  

Mesh:

Year:  1990        PMID: 2355321     DOI: 10.1016/s0886-3350(13)80705-5

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  143 in total

1.  New applications in ultrasound technology.

Authors:  H R Atta
Journal:  Br J Ophthalmol       Date:  1999-11       Impact factor: 4.638

2.  Predicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T.

Authors:  M J Elder
Journal:  Br J Ophthalmol       Date:  2002-06       Impact factor: 4.638

3.  Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

Authors:  Fatih Özcura; Serdar Aktaş; Hacı Murat Sağdık; Mehmet Tetikoğlu
Journal:  Int Ophthalmol       Date:  2016-02-08       Impact factor: 2.031

4.  Comparison of formulas and methods for high myopia patients requiring intraocular lens powers less than six diopters.

Authors:  Harry S Geggel
Journal:  Int Ophthalmol       Date:  2017-06-20       Impact factor: 2.031

5.  Comparison of intraocular lens power calculation methods in eyes that have undergone laser-assisted in-situ keratomileusis.

Authors:  Li Wang; Marc A Booth; Douglas D Koch
Journal:  Trans Am Ophthalmol Soc       Date:  2004

6.  Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

Authors:  Henry Gelender
Journal:  Trans Am Ophthalmol Soc       Date:  2006

7.  Intra-ocular lens power calculation in patients with high axial myopia before cataract surgery.

Authors:  Raouf El-Nafees; Ashraf Moawad; Hanem Kishk; Walid Gaafar
Journal:  Saudi J Ophthalmol       Date:  2010-04-04

8.  [Scheimpflug and topography systems in ophthalmologic diagnostics].

Authors:  G U Auffarth; A F M Borkenstein; A Ehmer; A Mannsfeld; T M Rabsilber; M P Holzer
Journal:  Ophthalmologe       Date:  2008-09       Impact factor: 1.059

9.  [Determination of toric intraocular lenses].

Authors:  A Langenbucher; Anja Viestenz; N Szentmáry; W Behrens-Baumann; A Viestenz
Journal:  Ophthalmologe       Date:  2008-07       Impact factor: 1.059

10.  [How can the shift of refraction due to vitreous substitutes be avoided? Posterior chamber intraocular lens for patients suffering from diabetic retinopathy].

Authors:  H Baraki; J Petersen
Journal:  Ophthalmologe       Date:  2011-07       Impact factor: 1.059