Comparison of the SRK/T formula and other theoretical and regression formulas.

D R Sanders1, J A Retzlaff, M C Kraff, H V Gimbel, M G Raanan.   

Abstract

We compared the predictive accuracy of the SRK/T formula to the SRK II, Binkhorst II, Hoffer, and Holladay formulas in seven series of cases totaling 1,050 eyes. In the combined group, the SRK/T and Holladay formulas performed only slightly better than the other formulas. In short eyes (less than 22 mm), all formulas performed well, with the SRK/T, SRK II, and Holladay formulas performing marginally better. In moderately long eyes (greater than 24.5 mm, less than or equal to 27 mm), the Hoffer and Binkhorst II formulas had a greater proportion of cases with greater than 2 diopters (D) of error and the SRK/T and Holladay were again marginally better. In the very long eyes (greater than 27 mm and less than or equal to 28.4 mm), there were only 11 cases and all formulas performed well since none had greater than 2 D of prediction error. In an extremely long eye data set (greater than 28.4 mm), the SRK II formula clearly gave the poorest result. Eyes of this length occurred in only 0.1% of cases in our unselected series. Results support the contention that the present second and third generation IOL power formulas give fairly equivalent accuracy. Other factors, such as availability, ease of use, and ability to tailor or individualize, become major considerations.

Entities:  

Mesh:

Year:  1990        PMID: 2355322     DOI: 10.1016/s0886-3350(13)80706-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  30 in total

1.  Measurement of axial length of eyes with incomplete filling of silicone oil in the vitreous cavity using x ray computed tomography.

Authors:  Kazuo Takei; Yasuo Sekine; Fumiki Okamoto; Sachiko Hommura
Journal:  Br J Ophthalmol       Date:  2002-01       Impact factor: 4.638

2.  Predicting the refractive outcome after cataract surgery: the comparison of different IOLs and SRK-II v SRK-T.

Authors:  M J Elder
Journal:  Br J Ophthalmol       Date:  2002-06       Impact factor: 4.638

3.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

4.  Calculation of the power of anterior chamber implants.

Authors:  J R Villada; P S Raj; T Akingbehin
Journal:  Br J Ophthalmol       Date:  1992-05       Impact factor: 4.638

5.  Refractive lens exchange with distance-dominant diffractive bifocal intraocular lens implantation.

Authors:  José F Alfonso; Luis Fernández-Vega; Susana Ortí; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-03-16       Impact factor: 3.117

6.  Comparison of the biometric formulas used for applanation A-scan ultrasound biometry.

Authors:  Fatih Özcura; Serdar Aktaş; Hacı Murat Sağdık; Mehmet Tetikoğlu
Journal:  Int Ophthalmol       Date:  2016-02-08       Impact factor: 2.031

7.  Intraocular lens power calculation after myopic and hyperopic laser vision correction using optical coherence tomography.

Authors:  Maolong Tang; Li Wang; Douglas D Koch; Yan Li; David Huang
Journal:  Saudi J Ophthalmol       Date:  2012-01

8.  The effect of pupillary dilatation on IOL power measurement by using the IOLMaster.

Authors:  Bharkbhum Khambhiphant; Nattida Chatbunchachai; Krit Pongpirul
Journal:  Int Ophthalmol       Date:  2015-03-26       Impact factor: 2.031

9.  An intraocular lens power calculation formula based on optical coherence tomography: a pilot study.

Authors:  Maolong Tang; Yan Li; David Huang
Journal:  J Refract Surg       Date:  2010-06-17       Impact factor: 3.573

10.  [Biometry in cataract camps. Experiences from north Kenya].

Authors:  S Briesen; H Roberts; J Karimurio; M Kollmann
Journal:  Ophthalmologe       Date:  2010-04       Impact factor: 1.059

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.