Literature DB >> 16985117

Higher intracoronary attenuation improves diagnostic accuracy in MDCT coronary angiography.

Filippo Cademartiri1, Nico R Mollet, Pedro A Lemos, Fransesco Saia, Massimo Midiri, Pim J de Feyter, Gabriel P Krestin.   

Abstract

OBJECTIVE: The purpose of this study was to investigate whether the amount of intracoronary attenuation influences the diagnostic accuracy of MDCT coronary angiography in the detection of clinically significant stenosis.
MATERIALS AND METHODS: One hundred twenty patients in sinus rhythm with suspected coronary artery disease who underwent MDCT of the heart and conventional coronary angiography were retrospectively selected. The population was divided into two groups depending on median (326 H) coronary vascular enhancement (i.e., low attenuation and high attenuation). The diagnostic accuracy of MDCT for the detection of clinically significant coronary artery lesions (> or = 50% lumen reduction) in both groups was compared with that of quantitative coronary angiography.
RESULTS: The sensitivity of MDCT was 90% and 93% for the low- and high-attenuation groups, respectively. The specificity was 95% and 97%.
CONCLUSION: Greater intracoronary attenuation leads to higher diagnostic accuracy in the detection of coronary artery stenosis with MDCT.

Entities:  

Mesh:

Year:  2006        PMID: 16985117     DOI: 10.2214/AJR.05.1406

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  32 in total

1.  Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality.

Authors:  Jean-François Paul
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-18       Impact factor: 2.357

Review 2.  A practical guide to reading CT coronary angiograms--how to avoid mistakes when assessing for coronary stenoses.

Authors:  John W M Hoe; Kok Hong Toh
Journal:  Int J Cardiovasc Imaging       Date:  2006-12-21       Impact factor: 2.357

3.  Influence of intra-coronary enhancement on diagnostic accuracy with 64-slice CT coronary angiography.

Authors:  Filippo Cademartiri; Erica Maffei; Anselmo Alessandro Palumbo; Roberto Malagò; Ludovico La Grutta; W Bob Meiijboom; Annachiara Aldrovandi; Michele Fusaro; Luigi Vignali; Alberto Menozzi; Valerio Brambilla; Paolo Coruzzi; Massimo Midiri; Miles A Kirchin; Nico R A Mollet; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2007-10-13       Impact factor: 5.315

4.  Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography.

Authors:  F Tatsugami; T Kanamoto; G Nakai; Y Takeda; H Morita; I Morinaga; S Yoshikawa; I Narabayashi
Journal:  Br J Radiol       Date:  2009-06-08       Impact factor: 3.039

5.  Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography.

Authors:  Takeshi Nakaura; Kazuo Awai; Yumi Yanaga; Tomohiro Namimoto; Daisuke Utsunomiya; Toshinori Hirai; Seigo Sugiyama; Hisao Ogawa; Masahito Aoyama; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2011-09-01       Impact factor: 2.374

6.  Relationship between diverse patient body size- and image acquisition-related factors, and quantitative and qualitative image quality in coronary computed tomography angiography: a multicenter observational study.

Authors:  Daisuke Utsunomiya; Ryoichi Tanaka; Kunihiro Yoshioka; Kazuo Awai; Teruhito Mochizuki; Naofumi Matsunaga; Tomoaki Ichikawa; Masayuki Kanematsu; Tonsok Kim; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2016-06-07       Impact factor: 2.374

7.  Optimization of exposure parameters for cone beam computed tomography sialography.

Authors:  F M Jadu; M L Hill; M J Yaffe; Ernest W N Lam
Journal:  Dentomaxillofac Radiol       Date:  2011-09       Impact factor: 2.419

8.  A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.

Authors:  Dominik C Benz; Christoph Gräni; Beatrice Hirt Moch; Fran Mikulicic; Jan Vontobel; Tobias A Fuchs; Julia Stehli; Olivier F Clerc; Mathias Possner; Aju P Pazhenkottil; Oliver Gaemperli; Ronny R Buechel; Philipp A Kaufmann
Journal:  Br J Radiol       Date:  2017-05-25       Impact factor: 3.039

9.  Comparison of iodinated contrast media for the assessment of atherosclerotic plaque attenuation values by CT coronary angiography: observations in an ex vivo model.

Authors:  L La Grutta; M Galia; G Gentile; G Lo Re; E Grassedonio; F Coppolino; E Maffei; E Maresi; A Lo Casto; F Cademartiri; M Midiri
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

10.  ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group.

Authors:  Masahiro Jinzaki; Kakuya Kitagawa; I-Chen Tsai; Carmen Chan; Wei Yu; Hwan Seok Yong; Byoung Wook Choi
Journal:  Int J Cardiovasc Imaging       Date:  2010-10-08       Impact factor: 2.357