Literature DB >> 27832419

Temporal averaging for analysis of four-dimensional whole-heart computed tomography perfusion of the myocardium: proof-of-concept study.

S Feger1, A Shaban1, S Lukas1, C Kendziorra2, M Rief1, E Zimmermann1, M Dewey3.   

Abstract

To assess the feasibility of four-dimensional (4D) whole-heart computed tomography perfusion (CTP) of the myocardium and the added value of temporal averaging of consecutive 3D datasets from different heartbeats for analysis. We included 30 patients with suspected or known coronary artery disease (CAD) who underwent 320-row coronary CT angiography (CTA) and myocardial CTP. Out of these, 15 patients underwent magnetic resonance myocardial perfusion imaging (MR MPI). All CTP examinations were initiated after 3 min of intravenous infusion of adenosine (140 µg/kg/min) and were performed dynamically covering the entire heart every heart beat over a period of 20 ± 3 heart beats. Temporal averaging for dynamic CTP visualisation was analysed for the combination of two, three, four, six, and eight consecutive 3D datasets. Input time attenuation curves (TAC) were delivered from measurement points in the centre of the left ventricle. In all 30 patients, myocardial 4D CTP was feasible and temporal averaging was successfully implemented for all planned combinations of 3D datasets. Temporal averaging of three consecutive 3D datasets showed best performance in the analysis of all CTP image quality parameters: noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, and diagnostic accuracy with an improvement of SNR and CNR by a factor of 2.2 ± 1.3 and 1.3 ± 0.9. With increasing level of temporal averaging, the input TACs became smoother, but also shorter. Out of the 11 perfusion defects detected with MR MPI, 9 defects were also visible on the 4D CTP images. Whole-heart CTP of the myocardium is feasible and temporal averaging of dynamic datasets improves quantitative image quality parameters and visualization of perfusion defects while further studies are needed to assess its added value for quantification of perfusion parameters.

Entities:  

Keywords:  Analysis; Computed tomography; Myocardium; Perfusion; Temporal averaging

Mesh:

Year:  2016        PMID: 27832419     DOI: 10.1007/s10554-016-1011-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  38 in total

1.  Nonrigid registration of dynamic medical imaging data using nD + t B-splines and a groupwise optimization approach.

Authors:  C T Metz; S Klein; M Schaap; T van Walsum; W J Niessen
Journal:  Med Image Anal       Date:  2010-10-28       Impact factor: 8.545

Review 2.  History of cardiac computed tomography: single to 320-detector row multislice computed tomography.

Authors:  Gregory S Hurlock; Hiroshi Higashino; Teruhito Mochizuki
Journal:  Int J Cardiovasc Imaging       Date:  2009-01-15       Impact factor: 2.357

3.  Myocardium: dynamic versus single-shot CT perfusion imaging.

Authors:  Armin M Huber; Vivian Leber; Bettina M Gramer; Daniela Muenzel; Alexander Leber; Johannes Rieber; Martin Schmidt; Mani Vembar; Ellen Hoffmann; Ernst Rummeny
Journal:  Radiology       Date:  2013-06-20       Impact factor: 11.105

4.  Multiple-cardiac-cycle noise reduction in dynamic optical coherence tomography of the embryonic heart and vasculature.

Authors:  Sandeep Bhat; Irina V Larina; Kirill V Larin; Mary E Dickinson; Michael Liebling
Journal:  Opt Lett       Date:  2009-12-01       Impact factor: 3.776

5.  Temporal filtering effects in dynamic parallel MRI.

Authors:  Martin Blaimer; Irene P Ponce; Felix A Breuer; Peter M Jakob; Mark A Griswold; Peter Kellman
Journal:  Magn Reson Med       Date:  2011-02-17       Impact factor: 4.668

6.  Adenosine stress high-pitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia: comparison with magnetic resonance imaging.

Authors:  Gudrun Feuchtner; Robert Goetti; André Plass; Monika Wieser; Hans Scheffel; Christophe Wyss; Paul Stolzmann; Olivio Donati; Johannes Schnabl; Volkmar Falk; Hatem Alkadhi; Sebastian Leschka; Ricardo C Cury
Journal:  Circ Cardiovasc Imaging       Date:  2011-08-23       Impact factor: 7.792

7.  Detection of hemodynamically significant coronary artery stenosis: incremental diagnostic value of dynamic CT-based myocardial perfusion imaging.

Authors:  Fabian Bamberg; Alexander Becker; Florian Schwarz; Roy P Marcus; Martin Greif; Franz von Ziegler; Ron Blankstein; Udo Hoffmann; Wieland H Sommer; Verena S Hoffmann; Thorsten R C Johnson; Hans-Christoph R Becker; Bernd J Wintersperger; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Radiology       Date:  2011-09       Impact factor: 11.105

8.  Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT: optimization of the CT protocol to reduce the radiation dose.

Authors:  Sung Mok Kim; Yoo Na Kim; Yeon Hyeon Choe
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-18       Impact factor: 2.357

9.  Incremental value of adenosine-induced stress myocardial perfusion imaging with dual-source CT at cardiac CT angiography.

Authors:  Jose A Rocha-Filho; Ron Blankstein; Leonid D Shturman; Hiram G Bezerra; David R Okada; Ian S Rogers; Brian Ghoshhajra; Udo Hoffmann; Gudrun Feuchtner; Wilfred S Mamuya; Thomas J Brady; Ricardo C Cury
Journal:  Radiology       Date:  2010-02       Impact factor: 11.105

10.  Dose reduction in dynamic CT stress myocardial perfusion imaging: comparison of 80-kV/370-mAs and 100-kV/300-mAs protocols.

Authors:  Makiko Fujita; Kakuya Kitagawa; Tatsuro Ito; Yasuyuki Shiraishi; Yusuke Kurobe; Motonori Nagata; Masaki Ishida; Hajime Sakuma
Journal:  Eur Radiol       Date:  2013-11-22       Impact factor: 5.315

View more
  6 in total

1.  Noise reduction and motion elimination in low-dose 4D myocardial computed tomography perfusion (CTP): preliminary clinical evaluation of the ASTRA4D algorithm.

Authors:  Steffen Lukas; Sarah Feger; Matthias Rief; Elke Zimmermann; Marc Dewey
Journal:  Eur Radiol       Date:  2019-02-04       Impact factor: 5.315

2.  Cardiovascular imaging 2017 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Amer Alaiti; Hiram G Bezerra; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2018-06       Impact factor: 2.357

3.  Cardiovascular imaging 2016 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Johan De Sutter; Paul Schoenhagen; Arthur E Stillman; Nico R L Vande Veire
Journal:  Int J Cardiovasc Imaging       Date:  2017-06       Impact factor: 2.357

4.  Improvement of image quality on low-dose dynamic myocardial perfusion computed tomography with a novel 4-dimensional similarity filter.

Authors:  Satonori Tsuneta; Noriko Oyama-Manabe; Hiroyuki Kameda; Taisuke Harada; Fumi Kato; Ewoud J Smit; Mathias Prokop; Kohsuke Kudo
Journal:  Medicine (Baltimore)       Date:  2020-06-26       Impact factor: 1.889

5.  Effect of iterative reconstruction and temporal averaging on contour sharpness in dynamic myocardial CT perfusion: Sub-analysis of the prospective 4D CT perfusion pilot study.

Authors:  Sarah Feger; Carsten Kendziorra; Steffen Lukas; Ahmed Shaban; Björn Bokelmann; Elke Zimmermann; Matthias Rief; Marc Dewey
Journal:  PLoS One       Date:  2018-10-16       Impact factor: 3.240

6.  Clinical quantitative cardiac imaging for the assessment of myocardial ischaemia.

Authors:  Marc Dewey; Maria Siebes; Marc Kachelrieß; Klaus F Kofoed; Pál Maurovich-Horvat; Konstantin Nikolaou; Wenjia Bai; Andreas Kofler; Robert Manka; Sebastian Kozerke; Amedeo Chiribiri; Tobias Schaeffter; Florian Michallek; Frank Bengel; Stephan Nekolla; Paul Knaapen; Mark Lubberink; Roxy Senior; Meng-Xing Tang; Jan J Piek; Tim van de Hoef; Johannes Martens; Laura Schreiber
Journal:  Nat Rev Cardiol       Date:  2020-02-24       Impact factor: 32.419

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.