Literature DB >> 24665181

Matrix miniplate versus locking miniplate in the management of displaced mandibular angle fractures.

R K Singh1, Sharad Chand2, U S Pal1, Sanjib K Das1, V P Sinha3.   

Abstract

AIM: The purpose of this study was to determine and compare various postoperative parameters like ease of operability, plate adaptability, stability etc., associated with use of matrix miniplate versus locking miniplate in the treatment of displaced mandibular angle fractures.
MATERIALS AND METHODS: The study was carried out in the Department of Oral and Maxillofacial surgery, King George's Medical College, GM and Associated Hospital, Lucknow. Total 50 patients were treated and included in the study. These were divided into two groups of 25 each and were treated with two of the standard techniques, i.e., one is matrix miniplate osteosynthesis and other is locking miniplate osteosynthesis. These patients were evaluated for postoperative complications and the differences between the two Groups were assessed.
RESULTS: Patients treated by matrix miniplate showed better recovery phase postoperatively as compared to locking miniplate group.
CONCLUSION: Based on this study matrix mini plate osteosynthesis may be considered as the better alternative method available for the treatment of displaced mandibular angle fractures.

Entities:  

Keywords:  Locking miniplate; mandibular fracture; matrix miniplate; post-operative complications

Year:  2013        PMID: 24665181      PMCID: PMC3961900          DOI: 10.4103/0975-5950.127656

Source DB:  PubMed          Journal:  Natl J Maxillofac Surg        ISSN: 0975-5950


INTRODUCTION

Mandible is a very prominent and vulnerable bone on the face[1] since the projected chin is a favored target of adversaries. Lower jaw plays a major role in the mastication, speech and deglutition. Its fracture result in severe loss of function and disfigurement.[2] The management of mandibular fractures varies in various maxillofacial units depending on the presentation, surgical expertise and the facilities available. The general principles of treatment for mandibular fractures do not differ from the treatment of fractures elsewhere in the body. The fragments are reduced into a proper position and then immobilized until such time as bony union occurs[3] i.e., reduction and fixation. Monocortical miniplates at superior border osteosynthesis of mandibular angle fracture is a world-wide technique[4] but lower border flaring and rotation of lower border of proximal fragment lingually due to pterygomasseteric sling results into loss of stability of fixation in three dimensional (3D) plane and to overcome this some sort of stabilization either a second miniplate[5] or a 3D plate (matrix miniplate) is required to control this rotation in the coronal plane in displaced angle fracture.

MATERIALS AND METHODS

This study included 50 patients of mandibular angle fractures, who were treated at the Department of Oral and Maxillofacial Surgery, King George's Medical University, GM and Associated Hospital, Lucknow. Informed consent was obtained. A standard history and examination chart was completed for each patient. Data concerning the patients' fracture etiology and pattern of fracture were also obtained and analyzed Orthopantogram (OPG) and posterior-anterior view of mandible were the standard radiographs. The radiological findings were recorded as fracture site, presence of additional mandibular fracture and degree of fracture dislocation. Patients were distributed into two groups and were treated with two of the standard techniques i.e., one is matrix miniplate osteosynthesis and other is locking miniplate osteosynthesis. 25 patients were included in each group. Group A: Matrix miniplate osteosynthesis. Group B: Locking miniplate osteosynthesis. The operation was performed under general anesthesia with nasotracheal intubation. Pre-operatively arch bar were placed for intra-operative Maxillomandibular fixation. All the plates were placed near tension trajectories using an intra-oral approach. Concomitant fractures were treated with miniplate fixation. Concurrent condylar fractures were treated by intermaxillary fixation for 21 days. Amoxicillinplus clavulanic acid 1.2 g was administered 3 times a day for 5 days. 0.1% chlorhexidine mouthwash was advised to maintain oral hygiene. Non-chewing liquid diet was advised for 6 weeks. Each patient was followed-up for 3-months' time. Post-operative OPG and posterior-anterior view was taken in follow-up for each patient, whenever required. During the follow-up period any complication found was recorded on the proforma.

RESULTS

In our study, the mandibular fractures were most commonly seen in body/parasymphysis region (64%) followed by their association with contralateral condylar fractures 24% and isolated angle fractures 12% of the total. The details are given in Table 1 and Figure 1.
Table 1

Location of fracture

Figure 1

Anatomical location of fractures

Location of fracture Anatomical location of fractures Both Groups A and B have 80-84% cases associated with high mobility of fracture fragments, and impairment in mouth opening was also predominantly high and equals 80% in both groups [Table 2].
Table 2

Displacement and mouth opening in different groups patients

Displacement and mouth opening in different groups patients 25 patients were treated with matrix miniplate [Figure 2] and 25 were treated with straight locking miniplate [Figure 3]. Details about post-operative complications related to the above two treatment modalities are given in Table 3.
Figure 2

Post operative check X-rays

Figure 3

Postoperative OPG X-ray

Table 3

Post-operative complications

Post operative check X-rays Postoperative OPG X-ray Post-operative complications

DISCUSSION

In this study, we have observed the fracture stability achieved by two different plates i.e., matrix miniplate and locking miniplate. We have found that matrix miniplate provided better stability in fixation over locking plate 3D in displaced angle fracture. About 80-84% patients of both Groups A and B reported with high mobility of fracture fragments attributable to the anatomy of the region involved i.e. opposing action of the pterygomasseteric sling and supra-hyoid muscles and delay in reporting of the cases. 80% of cases of each Groups A and B had impaired mouth opening and this is again attributable to regional anatomy, unstable nature of fracture and muscle guarding due to pain and swelling. Nearly 12% (3) patients of Group B reported infection when compared with 8% (2) patients of Group A during first follow-up depicted by persistent swelling and pain. Patients having infection were treated with antibiotics for 7 days and no surgical intervention or plate removal was required, probable reason for this may be improper oral hygiene measures adopted by the patients. Similar results were obtained by Ellis and Graham (2002)[7] who treated 28 patients out of 58 having mandibular angle fractures using locking miniplate and only 2 cases reported infection and no re-osteosynthesis was required Guimond et al.[8] in his retrospective evaluation of 37 patients having mandibular angle fractures fixed with curved angle strut plate reported an infection rate of 5.4% which compares favorably with reconstruction plate fixation. 12% cases of Group A when compared with 8% of Group B, reported wound dehiscence after a weeks' time which may be due to wide exposure of surgical site to accommodate large size plate and excessive retraction during screw placement. Jain et al.[9] in their study on 20 patients reported Champy's miniplate system as better and easier method than 3D miniplate system however he asserted that vertical bars incorporated in 3D plates provide good stability by countering the torque forces and due to simultaneous stabilization of both superior and inferior border operating time was less.[1013] 12% patients (3) of both groups reported paresthesia in first follow-up probably due to manipulation of fracture fragments for obtaining reduction., During second follow-up, 1 (4%) patient of Group A recovered from paresthesia while no improvement in paresthesia was found in patients of Group B. In third follow-up no patient of Group A reported paresthesia while 1 (4%) of Group B reported paresthesia. In final follow-up none of the patients of either groups reported paresthesia, above findings can be explained on the basis of stability of fixation" of the system utilized. Early resolution of paresthesia was found in patients of Group A as compared to Group B, this may be attributable to better stability of fixation with matrix miniplate. Guimond et al.[8] in their retrospective evaluation of 37 patients having mandibular angle fractures fixed with curved angle strut plate reported similar observation Post-operative malocclusion was noted in 02 (8%) cases of Group A as compared to 01 (4%) case Group B, this finding though adverse was probably due to improved stability of fixation in case of matrix miniplate than locking miniplate.[1112] Patients of both the groups which reported post-operative malocclusion were relieved by selective grinding and enameloplasty of the dentition. Jules et al.,[13] also reported similar findings of better intrinsic stability, more resistance to fracture fragment mobility in a series of 22 patients of mandibular angle fracture treated with 2.0 mm matrix miniplate. Similar results were reported by Ellis and Graham[7] and Gutwald et al.[14] using mini-locking plate. The former reported no impairment in occlusion in treating 58 patients with mandibular fractures and later asserted that a rigid frame was constructed in all three planes with the use of locking miniplate and the bone was loaded more evenly in contrast to conventional fixation techniques.

CONCLUSION

Our study indicates that matrix miniplate increases stability in fixation in displaced angle fractures than locking miniplate. There must be at least two mechanisms that must be considered when developing new strategies to reduce the incidence of complications and increase the 3D stability of fixation in displaced angle fracture. Matrix miniplate offers better alternative in managing displaced mandibular angle fractures.
  12 in total

1.  Principle and stability of locking plates.

Authors:  Ralf Gutwald; Brian Alpert; Rainer Schmelzeisen
Journal:  Keio J Med       Date:  2003-03

2.  Treatment modalities for mandibular angle fractures.

Authors:  Andrew J L Gear; Elena Apasova; John P Schmitz; Warren Schubert
Journal:  J Oral Maxillofac Surg       Date:  2005-05       Impact factor: 1.895

3.  "A comparative evaluation between single noncompression titanium miniplate and three dimensional titanium miniplate in treatment of mandibular angle fracture"--a randomized prospective study.

Authors:  K Vineeth; R M Lalitha; Kavitha Prasad; K Ranganath; V Shwetha; Jasmeet Singh
Journal:  J Craniomaxillofac Surg       Date:  2012-07-17       Impact factor: 2.078

4.  Use of rectangular grid miniplates for fracture fixation at the mandibular angle.

Authors:  Eduardo Hochuli-Vieira; Thi Khanh Linh Ha; Valfrido Antonio Pereira-Filho; Constantin Alexander Landes
Journal:  J Oral Maxillofac Surg       Date:  2011-01-08       Impact factor: 1.895

Review 5.  Treatment methods for fractures of the mandibular angle.

Authors:  E Ellis
Journal:  Int J Oral Maxillofac Surg       Date:  1999-08       Impact factor: 2.789

6.  Treatment of mandibular angle fractures - linea obliqua plate versus grid plate.

Authors:  Sebastian Herbert Höfer; Lin Ha; Alexander Ballon; Robert Sader; Constantin Landes
Journal:  J Craniomaxillofac Surg       Date:  2012-04-07       Impact factor: 2.078

7.  Comparison of 3-dimensional and standard miniplate fixation in the management of mandibular fractures.

Authors:  Manoj Kumar Jain; K S Manjunath; B K Bhagwan; Dipit K Shah
Journal:  J Oral Maxillofac Surg       Date:  2010-04-22       Impact factor: 1.895

8.  Fixation of mandibular angle fractures with a 2.0-mm 3-dimensional curved angle strut plate.

Authors:  Claude Guimond; James V Johnson; Jose M Marchena
Journal:  J Oral Maxillofac Surg       Date:  2005-02       Impact factor: 1.895

9.  Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle.

Authors:  Juergen Zix; Olivier Lieger; Tateyuki Iizuka
Journal:  J Oral Maxillofac Surg       Date:  2007-09       Impact factor: 1.895

10.  Aetiology of maxillofacial fracture.

Authors:  N Tanaka; K Tomitsuka; K Shionoya; H Andou; Y Kimijima; T Tashiro; T Amagasa
Journal:  Br J Oral Maxillofac Surg       Date:  1994-02       Impact factor: 1.651

View more
  3 in total

1.  Management of Mandibular Angle Fractures: Single Stainless Steel Linear Miniplate Versus Rectangular Grid Plate-A Prospective Randomised Study.

Authors:  Sridhar Reddy Kanubaddy; Sathya Kumar Devireddy; Kishore Kumar Rayadurgam; Rajsekhar Gali; Mallikarjun Rao Dasari; Sivaganesh Pampana
Journal:  J Maxillofac Oral Surg       Date:  2016-03-31

2.  Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

Authors:  Mahinder Singh; R K Singh; Deepak Passi; Mohit Aggarwal; Guneet Kaur
Journal:  J Oral Biol Craniofac Res       Date:  2015-10-17

3.  Role of fixation in posttraumatic nerve injury recovery in displaced mandibular angle fracture.

Authors:  R K Singh; U S Pal; Pranshu Singh; Geeta Singh
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.