Literature DB >> 22483950

Treatment of mandibular angle fractures - linea obliqua plate versus grid plate.

Sebastian Herbert Höfer1, Lin Ha, Alexander Ballon, Robert Sader, Constantin Landes.   

Abstract

OBJECTIVES: To compare treatment outcomes, handling and long term results between two osseo-fixation systems for mandibular angle fractures - the external oblique ridge (external oblique) plate and the grid plate.
MATERIAL AND METHODS: Sixty patients with mandibular angle fracture were analyzed regarding their operative treatment: 30 patients were treated with an external oblique plate and compared to 30 patients treated with a grid plate on the vestibular cortex. The follow up period was at least 1 year for both groups and the following complications were noted: infection, abnormality in fracture healing, nonunion, pain, hypoaesthesia and dysocclusion.
RESULTS: The overall average operation time (from intubation to extubation) was 102.1 min (± 44.1 min). Single sided fractures treated with the grid plate needed in average 81.07 min (± 37.9 min) of operation time while single sided fractures treated with the external oblique plate needed 89.3 min (± 42.2 min). In multiple mandibular fractures, no significant change in the operation time between either plating system was found (118.8 ± 35.2 min). After the follow up period fracture healing was considered clinically complete in all patients, but complications occurred significantly more often in the external oblique group (13.3%; N=8) than in the grid plate group (0%; N=0).
CONCLUSION: Isolated mandibular angle fractures can be more effectively treated using grid plates than using other osteosynthesis techniques. It is an easy to use alternative to conventional miniplate systems with good clinical outcome and fewer complications. An angulated burr and screwdriver has to be used to put on the plate laterally.
Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22483950     DOI: 10.1016/j.jcms.2012.02.021

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  12 in total

1.  Management of Mandibular Angle Fractures: Single Stainless Steel Linear Miniplate Versus Rectangular Grid Plate-A Prospective Randomised Study.

Authors:  Sridhar Reddy Kanubaddy; Sathya Kumar Devireddy; Kishore Kumar Rayadurgam; Rajsekhar Gali; Mallikarjun Rao Dasari; Sivaganesh Pampana
Journal:  J Maxillofac Oral Surg       Date:  2016-03-31

2.  Management of Angle Mandible Fractures by 3D Rectangular Grid Plate: A Prospective Study.

Authors:  Ramisetti Sudheer; Bathini Dilip Chakravarthy; Nandagopal Vura; Gaddipati Rajasekhar
Journal:  J Maxillofac Oral Surg       Date:  2019-09-17

3.  The Efficacy of Fixation of Unilateral Mandibular Angle Fracture with Single 3D Plate vs Single Miniplate Using Transbuccal Approach.

Authors:  Nancy Mathew; Inderjot Singh; Sumir Gandhi; Manisha Solanki; Navpreet Singh Bedi
Journal:  J Maxillofac Oral Surg       Date:  2020-10-19

4.  Management of mandibular angle fractures using a 1.7 mm 3-dimensional strut plate.

Authors:  Varnika Pandey; Ongkila Bhutia; Shakil Ahmed Nagori; Ashu Seith; Ajoy Roychoudhury
Journal:  J Oral Biol Craniofac Res       Date:  2015-11-27

Review 5.  Fixation of mandibular angle fractures: clinical studies.

Authors:  Bruno Ramos Chrcanovic
Journal:  Oral Maxillofac Surg       Date:  2012-11-24

6.  A 4-Year Multicentre Audit of Complications Following ORIF Treatment of Mandibular Fractures.

Authors:  Sathesh Balasundram; Ferdinand J Kovilpillai; Stephen J Royan; Bee Chai Ma; Dharmindra Rajah Gunarajah; Tassha Hilda Adnan
Journal:  J Maxillofac Oral Surg       Date:  2019-02-25

7.  The 3-dimensional miniplate is more effective than the standard miniplate for the management of mandibular fractures: a meta-analysis.

Authors:  Yong Liu; Bo Wei; Yuxiang Li; Dawei Gu; Guochao Yin; Bo Wang; Dehui Xu; Xuebing Zhang; Daliang Kong
Journal:  Eur J Med Res       Date:  2017-02-14       Impact factor: 2.175

8.  Routine removal of the plate after surgical treatment for mandibular angle fracture with a third molar in relation to the fracture line.

Authors:  Kazuhiko Yamamoto; Yumiko Matsusue; Satoshi Horita; Kazuhiro Murakami; Tsutomu Sugiura; Tadaaki Kirita
Journal:  Ann Maxillofac Surg       Date:  2015 Jan-Jun

9.  Matrix miniplate versus locking miniplate in the management of displaced mandibular angle fractures.

Authors:  R K Singh; Sharad Chand; U S Pal; Sanjib K Das; V P Sinha
Journal:  Natl J Maxillofac Surg       Date:  2013-07

10.  Evaluation of the Fatigue Performance and Degradability of Resorbable PLDLLA-TMC Osteofixations.

Authors:  Constantin Landes; Alexander Ballon; Shahram Ghanaati; Daniel Ebel; Dieter Ulrich; Uwe Spohn; Ute Heunemann; Robert Sader; Raimund Jaeger
Journal:  Open Biomed Eng J       Date:  2013-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.