Literature DB >> 24575952

Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews.

Chooryung J Chung1, Kil-Young Jung, Yoon Jeong Choi, Kyung-Ho Kim.   

Abstract

OBJECTIVES: To analyze morphological variations of retrieved orthodontic miniscrews and to evaluate the mechanical properties that may adversely affect relocation of miniscrews.
MATERIALS AND METHODS: Retrieved miniscrews were classified with scanning electron microscopy according to the degree of morphological deformation of the tip. To evaluate the differences in mechanical characteristics during reinsertion, changes in insertion torque, insertion time and differences in successful insertion load were compared between unused controls and retrieved miniscrews. In addition, surface composition analysis of retrieved miniscrews was performed using energy-dispersive x-ray spectroscopy.
RESULTS: Significant tip deformation was evident in the majority (>84.5%) of retrieved miniscrews. Initial conditions such as insertion site or duration of insertion were not associated with the presence of tip deformation. Insertion load for successful bone penetration increased in proportion to the degree of tip deformation; however, serial changes in insertion torque were similar to those of the controls. Deposited debris such as carbon, calcium, and phosphorus was noted on the retrieved miniscrews.
CONCLUSION: Miniscrews retrieved after primary insertion exhibited decreased cutting ability due to deformation of the tip structure, as well as surface contamination.

Entities:  

Keywords:  Miniscrew; Reinsertion; Relocation; Temporary anchorage device

Mesh:

Substances:

Year:  2014        PMID: 24575952      PMCID: PMC8641283          DOI: 10.2319/092613-703.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  19 in total

1.  Bone damage associated with orthodontic placement of miniscrew implants in an animal model.

Authors:  S Brooke Shank; F Michael Beck; Andrew M D'Atri; Sarandeep S Huja
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-04       Impact factor: 2.650

2.  Long-term stability of anterior open-bite treatment by intrusion of maxillary posterior teeth.

Authors:  Man-Suk Baek; Yoon-Jeong Choi; Hyung-Seog Yu; Kee-Joon Lee; Jinny Kwak; Young-Chel Park
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-10       Impact factor: 2.650

3.  Recommended placement torque when tightening an orthodontic mini-implant.

Authors:  Mitsuru Motoyoshi; Masayuki Hirabayashi; Miwa Uemura; Noriyoshi Shimizu
Journal:  Clin Oral Implants Res       Date:  2006-02       Impact factor: 5.977

4.  Risks and complications of orthodontic miniscrews.

Authors:  Neal D Kravitz; Budi Kusnoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-04       Impact factor: 2.650

5.  Root proximity is a major factor for screw failure in orthodontic anchorage.

Authors:  Shingo Kuroda; Kazuyo Yamada; Toru Deguchi; Takashi Hashimoto; Hee-Moon Kyung; Teruko Takano-Yamamoto
Journal:  Am J Orthod Dentofacial Orthop       Date:  2007-04       Impact factor: 2.650

6.  Characterization of retrieved orthodontic miniscrew implants.

Authors:  Theodore Eliades; Spiros Zinelis; Moschos A Papadopoulos; George Eliades
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-01       Impact factor: 2.650

7.  Microdamage of the cortical bone during mini-implant insertion with self-drilling and self-tapping techniques: a randomized controlled trial.

Authors:  Sumit Yadav; Madhur Upadhyay; Sean Liu; Eugene Roberts; William P Neace; Ravindra Nanda
Journal:  Am J Orthod Dentofacial Orthop       Date:  2012-05       Impact factor: 2.650

8.  Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants.

Authors:  C H Han; C B Johansson; A Wennerberg; T Albrektsson
Journal:  Clin Oral Implants Res       Date:  1998-02       Impact factor: 5.977

9.  Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density.

Authors:  H Watanabe; T Deguchi; M Hasegawa; M Ito; S Kim; T Takano-Yamamoto
Journal:  Orthod Craniofac Res       Date:  2012-09-03       Impact factor: 1.826

10.  Success rate and risk factors associated with mini-implants reinstalled in the maxilla.

Authors:  Seung-Hak Baek; Bo-Mi Kim; Seung-Hyun Kyung; Joong Ki Lim; Young Ho Kim
Journal:  Angle Orthod       Date:  2008-09       Impact factor: 2.079

View more
  3 in total

1.  Surface characteristics and mechanical behavior of retrieved orthodontic microimplants.

Authors:  Lu Lu; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018-05       Impact factor: 3.066

2.  Reader's Forum.

Authors:  Ju-Yeon Nam
Journal:  Korean J Orthod       Date:  2017-07-27       Impact factor: 1.372

3.  Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews.

Authors:  Soon-Dong Yun; Sung-Hwan Choi; Jung-Yul Cha; Hyung-Seog Yu; Kwang-Mahn Kim; Jin Kim; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2017-05-26       Impact factor: 1.372