Literature DB >> 22464522

Bone damage associated with orthodontic placement of miniscrew implants in an animal model.

S Brooke Shank1, F Michael Beck, Andrew M D'Atri, Sarandeep S Huja.   

Abstract

INTRODUCTION: The purposes of this study were to quantify bone damage associated with insertion of 2 types of miniscrew implants and to relate the amount of bone damage to monocortical plate thickness.
METHODS: Nondrilling (n = 28) and self-drilling (n = 28) miniscrew implants (6 × 1.6 mm, Dentaurum, Newtown, Pa), and pilot holes (n = 26) were placed bilaterally in the maxillae and the mandibles of 5 adult dogs immediately after death. Bone blocks were cut, bulk stained with 1% basic fuchsin, embedded in methyl methacrylate, sectioned, and mounted. Monocortical plate thickness was measured adjacent to the miniscrew implant insertion site. Damage amounts were quantified at distances of 0 to 0.5 mm (adjacent region) and 0.5 to 1 mm (distant region) from the bone-implant interface. Total fractional damaged area (%), fractional microcracked area (%), and fractional diffuse damaged area (%) were quantified by using standard histomorphometric methods.
RESULTS: The mean monocortical plate thickness of the specimens from the mandible (2.2 mm) was significantly (P <0.001) greater than that of the maxillary specimens (0.9 mm). In the mandible, the 3 damage parameters were greater with self-drilling miniscrew implants than with nondrilling miniscrew implants; however, there were no differences in the damage parameters in the maxilla.
CONCLUSIONS: Bone damage accumulation is related to the type of miniscrew implant and the thickness of the bone.
Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22464522     DOI: 10.1016/j.ajodo.2011.10.021

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  9 in total

1.  Primary migration of a mini-implant under a functional orthodontic loading.

Authors:  Joseph W Pittman; Anand Navalgund; Steve H Byun; Hechang Huang; Albert H Kim; Do-Gyoon Kim
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

2.  Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

Authors:  Merve Goymen; Eren Isman; Lale Taner; Mehmet Kurkcu
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

3.  Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study.

Authors:  Hemanth Tumkur Lakshmikantha; Naresh Kumar Ravichandran; Mansik Jeon; Jeehyun Kim; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018 Nov.       Impact factor: 3.066

4.  Levels of TGF-β1 in peri-miniscrew implant crevicular fluid.

Authors:  Avinash Kaur; Om Prakash Kharbanda; Moganty R Rajeswari; Dinesh Kalyanasundaram
Journal:  J Oral Biol Craniofac Res       Date:  2020-03-06

5.  Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews.

Authors:  Chooryung J Chung; Kil-Young Jung; Yoon Jeong Choi; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2014-03-03       Impact factor: 2.079

Review 6.  Profiles of inflammation factors and inflammatory pathways around the peri-miniscrew implant.

Authors:  Wendan He; Huazhang Zhu; Chufeng Liu
Journal:  Histol Histopathol       Date:  2021-04-09       Impact factor: 2.303

Review 7.  A review of biomarkers in peri-miniscrew implant crevicular fluid (PMICF).

Authors:  Avinash Kaur; Om P Kharbanda; Priyanka Kapoor; Dinesh Kalyanasundaram
Journal:  Prog Orthod       Date:  2017-11-27       Impact factor: 2.750

8.  MicroRNA expression profiles in peri-miniscrew implant crevicular fluid in orthodontics: a pilot study.

Authors:  Wendan He; Yanru Yang; Longgan Cai; Qiaoling Lei; Zhongdong Wang; Xiaoxia Che
Journal:  BMC Oral Health       Date:  2021-12-18       Impact factor: 2.757

9.  Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews.

Authors:  Soon-Dong Yun; Sung-Hwan Choi; Jung-Yul Cha; Hyung-Seog Yu; Kwang-Mahn Kim; Jin Kim; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2017-05-26       Impact factor: 1.372

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.