Literature DB >> 23311659

Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density.

H Watanabe1, T Deguchi, M Hasegawa, M Ito, S Kim, T Takano-Yamamoto.   

Abstract

OBJECTIVES: To test the hypothesis that there is no significant correlation between miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density. SETTING AND SAMPLE POPULATION: This study included 107 patients in whom 190 miniscrews had been placed from April 2008 to October 2009 in Tohoku University Hospital (Sendai, Japan).
MATERIALS AND METHODS: Cone beam computed tomography scans (CBCT) and periapical radiographs were taken before and after miniscrew placement. Differences in root proximity, screw insertion angle, bone contact length, and bone density were statistically compared; comparisons were also made between the CBCT images and periapical radiographs.
RESULTS: A significantly higher success rate was observed in the maxilla than in the mandible. The distance between the miniscrew and the root surface was significantly smaller in the failure group. There were no significant differences in the insertion angle, bone contact length, or bone density between the success group and the failure group. The concordance rate between the periapical dental radiographs and CBCT images was 46.5%.
CONCLUSION: While bone contact length, miniscrew angle, and bone density did not exert major effects on miniscrew failure, root proximity was the factor that most affected miniscrew failure, especially for miniscrews placed in the mandible. CBCT was superior to periapical dental X-rays for evaluating the proximity of miniscrews to the root. Correction of the X-ray attenuation coefficient value was necessary for measuring bone density using CBCT.
© 2012 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2012        PMID: 23311659     DOI: 10.1111/ocr.12003

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  21 in total

1.  Stainless steel or titanium mini-implants?

Authors:  Paulo Mecenas; Daybelis Gonzalez Espinosa; Paula Coutinho Cardoso; David Normando
Journal:  Angle Orthod       Date:  2020-07-01       Impact factor: 2.079

2.  Root proximity of miniscrews at a variety of maxillary and mandibular buccal sites: Reliability of panoramic radiography.

Authors:  Jae-Hwa An; Yong-Il Kim; Seong-Sik Kim; Soo-Byung Park; Woo-Sung Son; Sung-Hun Kim
Journal:  Angle Orthod       Date:  2019-03-11       Impact factor: 2.079

3.  A comparative assessment of orthodontic treatment outcomes of mild skeletal Class III malocclusion between facemask and facemask in combination with a miniscrew for anchorage in growing patients: A single-center, prospective randomized controlled trial.

Authors:  Masahiro Seiryu; Hiroto Ida; Atsushi Mayama; Satoshi Sasaki; Shutaro Sasaki; Toru Deguchi; Teruko Takano-Yamamoto
Journal:  Angle Orthod       Date:  2019-08-12       Impact factor: 2.079

4.  Evaluation of Interdental Spaces of the Mandibular Posterior Area for Orthodontic Mini-Implants with Cone-Beam Computed Tomography.

Authors:  Seyed Hossein Moslemzadeh; Aydin Sohrabi; Ali Rafighi; Yusef Kananizadeh; Amin Nourizadeh
Journal:  J Clin Diagn Res       Date:  2017-04-01

Review 5.  Two-dimensional radiographs versus cone-beam computed tomography in planning mini-implant placement: A systematic review.

Authors:  Gabriela-Franco-da Rosa Caetano; Mariana-Quirino-Silveira Soares; Luciana-Butini Oliveira; José-Luiz-Cintra Junqueira; Monikelly-do Carmo-Chagas Nascimento
Journal:  J Clin Exp Dent       Date:  2022-08-01

6.  A CBCT atlas of buccal cortical bone thickness in interradicular spaces.

Authors:  Patrick B Holmes; Bethany J Wolf; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

7.  Anatomical study of the maxillary tuberosity using cone beam computed tomography.

Authors:  Ester Manzanera; Paula Llorca; David Manzanera; Verónica García-Sanz; Vicente Sada; Vanessa Paredes-Gallardo
Journal:  Oral Radiol       Date:  2017-04-06       Impact factor: 1.852

8.  Effect of vertical placement angle on the insertion torque of mini-implants in human alveolar bone.

Authors:  Rafael Ribeiro Maya; Célia Regina Maio Pinzan-Vercelino; Julio de Araujo Gurgel
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

9.  Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews.

Authors:  Chooryung J Chung; Kil-Young Jung; Yoon Jeong Choi; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2014-03-03       Impact factor: 2.079

10.  Evaluation of mini-implant sites in the posterior maxilla using traditional radiographs and cone-beam computed tomography.

Authors:  Mona A Abbassy; Hanady M Sabban; Ali H Hassan; Khalid H Zawawi
Journal:  Saudi Med J       Date:  2015-11       Impact factor: 1.484

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.