Literature DB >> 9590939

Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants.

C H Han1, C B Johansson, A Wennerberg, T Albrektsson.   

Abstract

Screw shaped implants of commercially pure (c.p.) titanium and titanium-6aluminum-4vanadium (Ti6A14V) were blasted with particles of TiO2 of mean sizes of 25 microns (Group I) and 75 microns (Group II) and inserted in rabbit bone for 3 months. The surface roughness of the implants was examined and quantified with an optical scanning 3-dimensional instrument (TopScan 3D system), revealing the two alloy surfaces in each group had similar surface roughness. Biomechanical (removal torque) tests showed the c.p. titanium implants to be significantly more stable in the bone bed than those of Ti6A14V. In Group I, the c.p. titanium implants demonstrated a mean removal torque of 38 N cm while the Ti6A14V demonstrated a mean removal torque of 27 N cm (P = 0.004). Group II implants revealed a mean removal torque of 70 N cm for the c.p. ti and 50 N cm for the alloy samples (P = 0.003). The removal torque values were converted to shear forces/strengths by three calculation methods, based on (a) the entire length of the implant surface in the cortical region, (b) the thickness of the cortical bone measured in close vicinity to the thread peaks and (c) the bone-metal contact length measured on the non-unscrewed neighbouring implants. Group I: (a) the c.p. ti implants revealed a mean shear force of 4 vs a mean of 3 N/mm2 for the alloy samples. Shear strengths based on (b); were 8 for c.p. ti vs 6 N/mm2 for the alloy. The mean shear strength/force if calculated according to (c) revealed 23 for c.p. ti vs 18 N/mm2 for the alloy. Corresponding numbers for Group II; (a) c.p. ti 8 compared to 6 N/mm2 for the alloy, (b) c.p. ti demonstrated a mean value of 17 vs 11 N/mm2 for the alloy. According to method (c); c.p. ti had a mean shear strength of 26 vs 22 N/mm2 for the alloy samples. Histomorphometrical comparisons were performed on 10 microns thick undecalcified ground sections in the light microscope. In both Group I and Group II, the calculations of the mean bone-to-metal contact demonstrated more bone in contact to the c.p. titanium implants than to the Ti6A14V ones. Whereas comparisons of the bone volume inside the threads demonstrated slightly higher bone volumes around the alloy samples, no statistically significant difference was obtained between the two materials histomorphometrically.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9590939     DOI: 10.1034/j.1600-0501.1998.090101.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  17 in total

1.  Proteomic analysis of the biological response of MG63 osteoblast-like cells to titanium implants.

Authors:  Chang-Su Kim; Kee-Joon Lee; Jung-Eun Kim; Yun-Gyu Park; Jae-Jun Ryu; Hang-Rae Kim
Journal:  Odontology       Date:  2013-05-12       Impact factor: 2.634

2.  Histologic evaluation and removal torque analysis of nano- and microtreated titanium implants in the dogs.

Authors:  Seok Ahn; Mong-Sook Vang; Hong-So Yang; Sang-Won Park; Hyun-Pil Lim
Journal:  J Adv Prosthodont       Date:  2009-07-31       Impact factor: 1.904

3.  Tensile force testing of optimized coin-shaped titanium implant attachment kinetics in the rabbit tibiae.

Authors:  Hans Jacob Rønold; Jan Eirik Ellingsen; Ståle Petter Lyngstadaas
Journal:  J Mater Sci Mater Med       Date:  2003-10       Impact factor: 3.896

4.  Does sodium fluoride in bone cement affect implant fixation? Part I: bone tissue response, implant fixation and histology in nine rabbits.

Authors:  Mikael Sundfeldt; Michael Widmark; Ann Wennerberg; Johan Kärrholm; Carina B Johansson; Lars V Carlsson
Journal:  J Mater Sci Mater Med       Date:  2002-11       Impact factor: 3.896

5.  Biologic stability of plasma ion-implanted miniscrews.

Authors:  Young-Chae Cho; Jung-Yul Cha; Chung-Ju Hwang; Young-Chel Park; Han-Sung Jung; Hyung-Seog Yu
Journal:  Korean J Orthod       Date:  2013-06-24       Impact factor: 1.372

6.  Heat and radiofrequency plasma glow discharge pretreatment of a titanium alloy promote bone formation and osseointegration.

Authors:  Daniel E MacDonald; Bruce E Rapuano; Parth Vyas; Joseph M Lane; Kathleen Meyers; Timothy Wright
Journal:  J Cell Biochem       Date:  2013-10       Impact factor: 4.429

7.  Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews.

Authors:  Chooryung J Chung; Kil-Young Jung; Yoon Jeong Choi; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2014-03-03       Impact factor: 2.079

8.  Osseointegration of Titanium Implants in Onlay of Cerament™, a New Ceramic Bone Substitute.

Authors:  Anna Truedsson; Jian-Sheng Wang; Pia Lindberg; Gunnar Warfvinge
Journal:  J Funct Biomater       Date:  2016-01-07

9.  An Ultrasound Assisted Anchoring Technique (BoneWelding Technology) for Fixation of Implants to Bone - A Histological Pilot Study in Sheep.

Authors:  Jens D Langhoff; Jan M Kuemmerle; Joerg Mayer; Urs Weber; Milica Berra; Jessika M Mueller; Sabine B Kaestner; Katalin Zlinszky; Joerg A Auer; Brigitte von Rechenberg
Journal:  Open Orthop J       Date:  2009-06-11

10.  Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae.

Authors:  Nam-Seok Kang; Lin-Jie Li; Sung-Am Cho
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.