Impact of sirolimus-eluting stent fractures without early cardiac events on long-term clinical outcomes: a multislice computed tomography study.

Tsuyoshi Ito1, Masashi Kimura, Mariko Ehara, Mitsuyasu Terashima, Kenya Nasu, Yoshihisa Kinoshita, Maoto Habara, Etsuo Tsuchikane, Takahiko Suzuki.   

Abstract

OBJECTIVES: This study sought to evaluate the impact of sirolimus-eluting stent (SES) fractures on long-term clinical outcomes using multislice computed tomography (MSCT).
METHODS: In this study, 528 patients undergoing 6- to 18-month follow-up 64-slice MSCT after SES implantation without early clinical events were followed clinically (the median follow-up interval was 4.6 years). A CT-detected stent fracture was defined as a complete gap with Hounsfield units (HU) <300 at the site of separation. The major adverse cardiac events (MACEs), including cardiac death, stent thrombosis, and target lesion revascularisation, were compared according to the presence of stent fracture.
RESULTS: Stent fractures were observed in 39 patients (7.4 %). MACEs were more common in patients with CT-detected stent fractures than in those without (46 % vs. 7 %, p < 0.01). Univariate Cox regression analysis indicated a significant relationship between MACE and stent fracture [hazard ratio (HR) 7.65; p < 0.01], age (HR 1.03; p = 0.04), stent length (HR 1.03; p < 0.01), diabetes mellitus (HR 1.77; p = 0.04), and chronic total occlusion (HR 2.54; p = 0.01). In the multivariate model, stent fracture (HR 5.36; p < 0.01) and age (HR 1.03; p = 0.04) remained significant predictors of MACE.
CONCLUSIONS: An SES fracture detected by MSCT without early clinical events was associated with long-term clinical adverse events. KEY POINTS: • Long-term outcomes of sirolimus-eluting stent fracture have not been fully clarified. • MSCT could detect stent fracture with high accuracy. • Sirolimus-eluting stent fracture detected by MSCT was associated with long-term adverse events.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24567235     DOI: 10.1007/s00330-014-3118-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  30 in total

1.  Very late stent thrombosis and late target lesion revascularization after sirolimus-eluting stent implantation: five-year outcome of the j-Cypher Registry.

Authors:  Takeshi Kimura; Takeshi Morimoto; Yoshihisa Nakagawa; Kazuya Kawai; Shunichi Miyazaki; Toshiya Muramatsu; Nobuo Shiode; Masanobu Namura; Takahito Sone; Shigeru Oshima; Hideo Nishikawa; Yoshikazu Hiasa; Yasuhiko Hayashi; Masakiyo Nobuyoshi; Kazuaki Mitudo
Journal:  Circulation       Date:  2011-12-27       Impact factor: 29.690

Review 2.  Prognostic value of cardiac computed tomography angiography: a systematic review and meta-analysis.

Authors:  Edward A Hulten; Salvatore Carbonaro; Sara P Petrillo; Joshua D Mitchell; Todd C Villines
Journal:  J Am Coll Cardiol       Date:  2010-12-08       Impact factor: 24.094

3.  ACCF/SCCT/ACR/AHA/ASE/ASNC/NASCI/SCAI/SCMR 2010 appropriate use criteria for cardiac computed tomography. A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the Society of Cardiovascular Computed Tomography, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the American Society of Nuclear Cardiology, the North American Society for Cardiovascular Imaging, the Society for Cardiovascular Angiography and Interventions, and the Society for Cardiovascular Magnetic Resonance.

Authors:  Allen J Taylor; Manuel Cerqueira; John McB Hodgson; Daniel Mark; James Min; Patrick O'Gara; Geoffrey D Rubin; Christopher M Kramer; Daniel Berman; Alan Brown; Farooq A Chaudhry; Ricardo C Cury; Milind Y Desai; Andrew J Einstein; Antoinette S Gomes; Robert Harrington; Udo Hoffmann; Rahul Khare; John Lesser; Christopher McGann; Alan Rosenberg; Robert Schwartz; Marc Shelton; Gerald W Smetana; Sidney C Smith
Journal:  J Am Coll Cardiol       Date:  2010-11-23       Impact factor: 24.094

4.  Comparison of in vivo assessment of vulnerable plaque by 64-slice multislice computed tomography versus optical coherence tomography.

Authors:  Tsuyoshi Ito; Mitsuyasu Terashima; Hideaki Kaneda; Kenya Nasu; Hitoshi Matsuo; Mariko Ehara; Yoshihisa Kinoshita; Masashi Kimura; Nobuyoshi Tanaka; Maoto Habara; Osamu Katoh; Takahiko Suzuki
Journal:  Am J Cardiol       Date:  2011-02-23       Impact factor: 2.778

5.  Long-term clinical and angiographic outcomes of patients with sirolimus-eluting stent fracture.

Authors:  Ung Kim; Doo-Il Kim; Dong-Kie Kim; Sang-Hoon Seol; Jae-Sik Jang; Tae-Hyun Yang; Dae-Kyeong Kim; Dong-Soo Kim; Ho-Ki Min; Kang-Joo Choi
Journal:  Int J Cardiol       Date:  2011-04-11       Impact factor: 4.164

6.  Incidence and predictors of drug-eluting stent fracture in human coronary artery a pathologic analysis.

Authors:  Gaku Nakazawa; Aloke V Finn; Marc Vorpahl; Elena Ladich; Robert Kutys; Isidora Balazs; Frank D Kolodgie; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2009-11-17       Impact factor: 24.094

7.  Frequency, predictors and outcome of stent fracture after sirolimus-eluting stent implantation.

Authors:  Hisashi Umeda; Tomoko Gochi; Mitsunori Iwase; Hideo Izawa; Takeshi Shimizu; Ryoji Ishiki; Haruo Inagaki; Junji Toyama; Mitsuhiro Yokota; Toyoaki Murohara
Journal:  Int J Cardiol       Date:  2008-03-14       Impact factor: 4.164

8.  Classification and potential mechanisms of intravascular ultrasound patterns of stent fracture.

Authors:  Hiroshi Doi; Akiko Maehara; Gary S Mintz; Kenichi Tsujita; Takashi Kubo; Celia Castellanos; Jian Liu; Junqing Yang; Carlos Oviedo; Jiro Aoki; Theresa Franklin-Bond; Neil Dasgupta; Alexandra J Lansky; George D Dangas; Gregg W Stone; Jeffrey W Moses; Roxana Mehran; Martin B Leon
Journal:  Am J Cardiol       Date:  2009-03-15       Impact factor: 2.778

9.  Dual source coronary computed tomography angiography for detecting in-stent restenosis.

Authors:  F Pugliese; A C Weustink; C Van Mieghem; F Alberghina; M Otsuka; W B Meijboom; N van Pelt; N R Mollet; F Cademartiri; G P Krestin; M G M Hunink; P J de Feyter
Journal:  Heart       Date:  2007-09-19       Impact factor: 5.994

10.  A qualitative and quantitative angiographic analysis of stent fracture late following sirolimus-eluting stent implantation.

Authors:  Jeffrey J Popma; Klaus Tiroch; Alexandra Almonacid; Sidney Cohen; David E Kandzari; Martin B Leon
Journal:  Am J Cardiol       Date:  2009-04-01       Impact factor: 2.778

View more
  2 in total

1.  Coronary stent thrombosis: what have we learned?

Authors:  Carlos Collet; Yohei Sotomi; Rafael Cavalcante; Pannipa Suwannasom; Erhan Tenekecioglu; Yoshinobu Onuma; Patrick W Serruys
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

2.  Incidence of coronary drug-eluting stent fracture: A systematic review and meta-analysis.

Authors:  Yang Chen; Dandan Li; Yanhui Liao; Xiongda Yao; Yuehua Ruan; Kai Zou; Hanhui Liao; Jingwen Ding; Hao Qin; Zuozhong Yu; Yuanbin Zhao; Longlong Hu; Renqiang Yang
Journal:  Front Cardiovasc Med       Date:  2022-08-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.